IGBT Module
Collector-Emitter Voltage (Vces):1200V
Collector Current (Ic @ 25°C):450A
Collector Current (Ic @ 80°C):300A
Pulse Current (Icm):900A
Power Dissipation (Ptot):1800W
Gate-Emitter Voltage (Vges):±20V
Turn-on Delay Time (tdon):110ns
Rise Time (tr):50ns
Turn-off Delay Time (tdoff):400ns
Fall Time (tf):120ns
Switching Frequency:Up to 20kHz
Bus Coupler
Supply Voltage: 24V DC (19.2-30V DC)
Power Consumption: 1.5W
Current Capacity: 6A
Isolation Voltage: 500V AC
Fieldbus Protocol:PROFIBUS DP-V1
Data Rate:Up to 12 Mbps
Address Range:1-125 (PROFIBUS)
I/O Connection:S800 I/O bus
TEMP MEASURING BOARD
Input Channels:4 or 8 (isolated)
Supported Sensors:PT100/PT1000, TC (J/K/T/E), 0-20mA, ±10V
Measurement Accuracy:±0.1% FS (RTD), ±1°C (TC)
Resolution:0.01°C (RTD), 0.1°C (TC)
Update Rate:100ms per channel
Isolation:1500V AC
Power Supply: 24V DC (±10%) via backplane
Power Consumption: <3W
Input Impedance: >1MΩ
Max. Input Voltage: ±15V
Gate Circuit Board
DRIVE
IGBT
BOARD KIT
Modbus TCP/IP
-20°C to 60°C (-4°F to 140°F)
Number of Inputs: 16
Number of Outputs: 16
07KT98 Advant Controller 31 Basic Unit
Microprocessor-based protection
Three-phase trip-free mechanism
Front-connected auxiliary contacts
Integrated earth fault protection
Remote control and monitoring capabilities
High-performance AC800F platform
Supports a wide range of I/O modules
Supports a variety of programming languages
Suitable for a wide range of industrial applications
Compact and modular design
Frequency Converter Driver Board
Voltage Input: 380V to 690V AC (3-phase)
Switching Frequency: 2–16 kHz range
Operating Temperature: -10°C to +50°C (ambient, typical)
Humidity: ≤95% non-condensing
Power Supply
Input Voltage Range: 85-264V AC (universal input)
Input Frequency: 47-63Hz
Inrush Current: <25A (at 115V AC), <50A (at 230V AC)
Power Factor: >0.95 (at full load)
Efficiency: 92% typical
Output Voltage: 24V DC
Output Current: 6A continuous
Current Limit: 7.5A
Ripple & Noise: <150mV p-p
Load Regulation: ±0.5% (10-100% load)
Line Regulation: ±0.2% (85-264V AC)
BRC400 Bridge Controller
CONTROLLER
HARMONY BRIDGE
BRC400
BUTTON CELL BATTERY
SINGLE PORT
RELAY OUTPUT
Servo Control Board
Memory:64MB DDR3, 16MB Flash
Operating Voltage:24V DC ±10%
Power Consumption:15W typical
Control Loop :62.5μs update rate
Position Resolution:24-bit (0.0001°)
Velocity Ripple:<0.02% of rated speed
Torque Control:±0.5% of rated torque
Motor Outputs:3-phase PWM (up to 20kHz)
Encoder Inputs:2x EnDat 2.2/SSI (26-bit)
Digital I/O:8x 24V DC inputs, 4x 0.5A outputs
DC drive motherboard
Memory:32MB SDRAM
Control Loop Time:100μs (speed)
Digital I/O:12x 24V DC inputs
Supply Voltage:24V DC ±10%
Power Consumption:15W max
Isolation :2500V AC
Control Board
Clock Speed:150MHz (DSP), 100MHz (FPGA)
Memory:512kB Flash, 68kB SRAM
Operating Voltage:24V DC ±10%
Power Consumption:12W typical
Isolation:2500V AC
Control Loop Update: 62.5μs (speed)
Analog Inputs:2 ch (16-bit, ±10V/4-20mA)
Digital Inputs:6 ch (24V DC, 3ms filter)
Relay Outputs:3 ch (250V AC/5A)
PTC Input:2 ch (Motor temp sensors)
POWER SUPPLY CARD
Input Voltage Range: 85–264 VAC
Input Frequency: 47–63 Hz
Input Current: 3.5 A max @ 120 VAC, 1.8 A max @ 240 VAC
Inrush Current: 30 A (typical, cold start)
Power Factor: >0.95 (at full load)
Output Voltage: 24 VDC (±1%)
Digital Output Module
Relay Version: 5–250 VAC/VD
Solid-State Version: 24 VDC
Switching Frequency Relay: ≤5 Hz
Solid-State: ≤100 Hz
Channel-to-Channel: 500 VAC
Channel-to-Backplane: 1500 VAC
Main Control Circuit Board
PROFIBUS DP
PROFINET
Modbus RTU/TCP
Ethernet/IP
Clock Speed: ≥200 MHz
Supply Voltage: 24 VDC (±10%)
Power Consumption: Typically <15W
Communication Module
PROFIBUS: 9.6 kbps to 12 Mbps
Modbus TCP: 10/100 Mbps
PROFIBUS: 9-pin D-sub
Ethernet: RJ45
Terminal blocks for serial communication
PROFIBUS: Up to 124 slaves
Modbus: 247 RTU devices
Isolation: 1500 VAC
Interface Board
Number of channels: 16 (configurable)
Voltage range: 24 VDC (18-30V)
Input impedance: 3kΩ
Isolation: 500V channel-to-channel
Switching capacity: 0.5A @ 24VDC
Supply Voltage: 24 VDC (±10%)
Power Consumption: <3W typical
Robot Drive Unit
Input Voltage:3-phase 200-480VAC (±10%)
DC Bus Voltage: 600VDC nominal
Power Rating: 7.5kW (varies by configuration)
Peak Current: 25A (3 sec)
Continuous Current: 12A
PWM Frequency: 8kHz
Control Cycle Time: 0.5ms
Overload Capacity: 200% for 3 seconds
Control Board
Main Processor: 32-bit DSP + FPGA
Clock Speed: ≥300 MHz
Memory Flash: 128MB
Control Cycle Time: <100μs
Digital Inputs: 8 channels (24VDC)
Digital Outputs: 4 channels (relay)
Analog Inputs: 2 channels (±10V/4-20mA)
Analog Outputs: 2 channels (0-10V/4-20mA)
DriveBus Interface Module
Data rate: 10 Mbps
Max. distance: 100m (fiber length)
ModuleBus connection to AC 800M
Supply voltage: 24 VDC (±10%)
Power consumption: <5 W
Isolation: 1500 VAC
Supports up to 12 drives per module
Optical Module
Operating Voltage: 24 Vdc (±10%).
Data Rate: 100 Mbps
Operating Temperature: -40°C to +70°C
Humidity: 5–95% non-condensing
Control Module
Clock Speed: 500-800 MHz
RAM: 256MB-512MB DDR
Flash Storage: 512MB-1GB
Digital Inputs: 16-32 channels
Analog Inputs: 8-16 channels
2x Ethernet (10/100/1000 Mbps)
1x RS-232/485 (configurable)
1x USB (Type A, for maintenance)
Speed Module
Power Supply:24V DC (±10%)
Tachometer input: 0-10V DC or 4-20mA
Pulse input: Up to 100kHz frequency
Analog output: ±10V DC or 4-20mA
Relay outputs: 2x SPDT (5A @ 250V AC)
Speed Range: 0-10,000 RPM (configurable)
Resolution: 0.1% of full scale or better
Digital outputs: 24V DC, 0.5A
Analog output module
Voltage: 0-10V DC, ±10V DC
Current: 4-20mA, 0-20mA
Load Capacity:Voltage: ≥1kΩ
Isolation:1500V AC channel-to-channel
Backplane Power: 5V DC @ 500mA (typical)
Field Power: 24V DC (±10%) for outputs
Power Consumption: 6W (typical)
High Voltage Inverter Board
Voltage Rating: 1200V–1700V
Input Voltage (DC Link): 300–1000V DC
Output Voltage (AC): 3-phase, 0–480V AC
Current Rating: Up to 500A
Switching Frequency: 2–20 kHz
Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.