ABB CI865K01
· Product image is representative; revision or series may vary. Contact us to request a specific version.
Ships by Friday, November 27

CI865K01

Communication interface kit

Shipping Information

  • For inventory products, we support same day shipping upon payment.
  • For urgent needs, we offer same-day shipping on most items for orders placed before 2:00 PM UTC+8 Simply mention your preferred next-day shipping when place the order, and your order will be prioritized to minimize downtime.
  • For indent items, typical turnaround is 1-3 weeks, depending on parts availability and scarcity.
Customs & Documentation
We prepare clear, order-specific documentation for every international shipment, including the commercial invoice, packing list and available product or compliance documents. Before dispatch, our logistics team confirms the consignee details, declared value, shipping terms and destination requirements with you. Tracking information is provided after shipment, helping your team prepare for import clearance with confidence.
Documents checked before dispatch · Shipment details confirmed · Global tracking provided
Payment
Payment is by bank wire only in RMB/CNY, GBP, EUR or USD. Amikon does not accept credit cards or provide credit terms. Cleared payment is required before shipment unless the written quotation expressly states otherwise.
Product Condition
Factory New These are new and current items that are procured directly from the manufacturer.
New In Sealed Package Parts are new. They have not been used and still have their original package seal intact.
New in Original Package These parts are new. The packages were not originally sealed by their original manufacturer.
Quantity
Mobile *
Country/Region *
E-mail *
Company
Content *
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Amikong please read our privacy policy.
  • 20+

    years in automation
  • ISO 9001

    certified quality system
  • 12 months

    amikon warranty
  • 2-hour reply

    from your account manager
  • Success Story

    solutions in action
PRODUCT DESCRIPTION

CI865K01 Communication interface kit

ABB CI865K01 is an AC 800M communication interface kit for Satt I/O. It includes the communication unit and its TP865 baseplate, linking the controller CEX-Bus to the documented external communication arrangement.

CI865 connects Satt 19-inch rack I/O and S200 I/O using the documented ControlNet-based connection. Its BNC interface is supplied from the CEX-Bus, with 120 mA typical consumption and up to four interfaces per controller. Both the interface and baseplate must retain their matching mechanical coding.
ACTUAL APPLICATIONS

Application fields for CI865K01

ABB CI865K01 is an AC 800M communication interface kit for Satt I/O. It includes the communication unit and its TP865 baseplate, linking the controller CEX-Bus to the documented external communication arrangement.
  • 01 · METALS

    Mineral Mining and
    Primary Metallurgy

    Ferrous mineral mining and primary metallurgyNonferrous mineral mining and secondary metallurgy
  • 02 · PULP & PAPER

    Print Publishing and
    Visual Communication

    Paper, graphic communication and commercial printingPrint publishing and commercial visual communication
  • 03 · WATER & WASTEWATER

    Water Treatment and
    Municipal Sanitation

    Public drinking water and urban water treatmentMunicipal wastewater treatment and public sanitation

Technical specifications for CI865K01

  • Product Model
    CI865K01
  • Product Parameters
    Communication interface kit
  • In stock
    7 units
  • Manufacturer
    ABB
  • Communication protocol
    Satt I/O
  • Operating role
    Master
  • Maximum CEX units
    4
  • Network connector
    BNC
  • CEX supply
    24 V DC
  • Typical supply current
    120 mA
  • Line redundancy
    Not supported
  • Module redundancy
    Not supported
  • Hot insertion
    Supported
  • High Integrity controller use
    Not supported
  • Operating temperature
    0 to +55 deg C
  • Storage temperature
    -40 to +70 deg C
  • Ingress protection
    IP20
  • Corrosion classification
    ISA 71.04 G3
  • CE marking
    Yes
View all additional

Alternative Names

CI865K01 AC 800M Satt I/O Communication interface kit
SYSTEM & REPLACEMENT CHECK

Information needed before ordering

Three direct checks to secure your system integration and minimize ordering risks.

Information

System integration Replacement check Manuals & support
SYSTEM INTEGRATION

Integrate CI865K01 within AC 800M Satt I/O

Mount the TP865 baseplate on the controller DIN rail and retain its coded match with the CI865K01 communication unit. The CEX-Bus supplies the interface from 24 V DC.
Connect the BNC communication port to the documented Satt I/O network. CI865 is intended for the supported Satt 19-inch rack and S200 I/O arrangement; it is not a general-purpose Ethernet adapter.
Allow for 120 mA typical CEX current and the limit of 4 interfaces. Confirm communication diagnostics and the configured I/O exchange after startup.

Features:

  • Communication protocol: Satt I/O
  • Operating role: Master
  • AC 800M Satt I/O
Use CI865K01 only within the documented AC 800M Satt I/O arrangement and applicable installation instructions.
INTERCHANGEABILITY

Replace CI865K01 within AC 800M Satt I/O

Keep CI865K01 and TP865 together as the specified kit. Mechanical similarity to another CI8xx interface does not establish protocol or baseplate compatibility.
The documented interface supports Satt I/O and hot insertion, but does not provide line or module redundancy. Follow the site maintenance and isolation procedure before exchanging it.
Restore the saved Satt I/O configuration and verify the external communication path, CEX recognition and live data exchange.

Features:

  • Communication protocol: Satt I/O
  • Operating role: Master
  • AC 800M Satt I/O
Use CI865K01 only within the documented AC 800M Satt I/O arrangement and applicable installation instructions.
DOCUMENTATION STATUS

Browse the Manuals, Datasheets, Official Documents, Links

Important Notice: The linked files are Amikong-hosted reference documents. Match their product identity and scope to the supplied assembly, and consult the applicable manufacturer instructions before use. Accessories and additional documents are included only when expressly listed in the quotation.

Features:

  • Exact-model technical data for CI865K01
  • Document applicability checked against the complete identity
  • Directory links by subcategory and brand
Documentation for CI865K01 must match the installed product identity and supplied configuration.

Important notice

Manuals, software, firmware, cables, calibration data and accessories are included only when listed in the quotation. AMIKON is an independent supplier and is not affiliated with or authorised by the manufacturer.
This content has been produced using multiple sources. Takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
BUYER INFORMATION

Commercial terms without hidden steps

Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • 01

    Shipping & delivery

    Dispatch
    Eligible stock: same / next day
    Carriers
    DHL, FedEx or UPS
    Ship from
    Xiamen, China
    Product size
    5.90 x 18.50 x 12.75 cm
    Net weight
    0.70 kg
  • 02

    Payment & customs

    Payment
    Bank transfer (T/T)
    Currencies
    USD · EUR · GBP · RMB
    Credit cards
    Not accepted
    HS reference
    85389099
    Origin
    Switzerland
  • 03

    Warranty & returns

    Warranty
    12 months from AMIKON
    Inspection
    Label, condition and packing checks
    Returns
    Prior RMA authorisation required
    Compatibility
    Confirm before order
    OEM warranty
    Does not apply
Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • Part checked

    Full suffix recorded
  • Condition checked

    Label and appearance
  • Packing checked

    Antistatic protection
  • Tracking supplied

    Established couriers
  • Sandy Lin

    Dedicated account manager · 15+ years
FREQUENTLY ASKED QUESTIONS

Questions buyers ask about CI865K01

Direct answers about identity, compatibility, stock, warranty, payment and shipping.
  • Which existing I/O connection is CI865K01 intended to preserve?

    CI865K01 is the AC 800M master interface for the documented Satt I/O connection. Establish that the installed equipment is the supported Satt I/O arrangement before selecting it for a legacy I/O migration or repair.
  • What physical network connection should maintenance identify on CI865K01?

    The CI865K01 specification identifies a BNC network connector. Check the installed Satt I/O cabling and the TP865 arrangement rather than assuming an RJ45 Ethernet cable connects to this interface.
  • Does CI865K01 work in an AC 800M High Integrity controller arrangement?

    The catalog marks High Integrity controller use as not supported for CI865K01. Do not transfer it into a safety-controller configuration merely because it mounts on the same controller communication bus.
  • What is the CI865-specific population limit during a CEX expansion review?

    A maximum of four CI865 units is listed for CI865K01. The processor's higher overall CEX capacity does not override that Satt I/O interface limit.
  • Can two CI865 modules be assumed to form a redundant communication pair?

    No. CI865K01 lists neither module redundancy nor line redundancy. A pair of installed modules does not by itself establish a supported redundant Satt I/O arrangement.
  • How should CI865K01 hot insertion and its supply demand be considered during service?

    The catalog supports CI865K01 hot insertion and specifies 120 mA typical consumption from the 24 V DC CEX supply. Follow the applicable service procedure and include that current when assessing the installed bus supply.
  • What paired hardware belongs on a CI865K01 purchase specification?

    Name the CI865 communication interface and its TP865 baseplate as the CI865K01 kit. Record the Satt I/O role explicitly so another CEX master interface is not supplied as an apparent equivalent.
  • Which CI865K01 checks distinguish a received kit from a mismatched legacy spare?

    Check the CI865K01 identification and revision, TP865 baseplate, BNC connection and stated supplied accessories against the order. A different baseplate or protocol identity needs resolution before connection to the Satt I/O installation.
READY TO VERIFY YOUR PART?

Get a CI865K01 quote with price, lead time and revision check.

Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: Amikon Limited sells new and surplus products and develops channels for purchasing such products. Amikon Limited is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because Amikon Limited is not an authorized distributor of this product, the Original Manufacturer's warranty does not apply. Amikon Limited is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.
Product

Product Browsing History