ABB 1SDA051266R1
· Product image is representative; revision or series may vary. Contact us to request a specific version.
Ships by Saturday, November 28

1SDA051266R1

Thermomagnetic molded-case circuit breaker

Shipping Information

  • For inventory products, we support same day shipping upon payment.
  • For urgent needs, we offer same-day shipping on most items for orders placed before 2:00 PM UTC+8 Simply mention your preferred next-day shipping when place the order, and your order will be prioritized to minimize downtime.
  • For indent items, typical turnaround is 1-3 weeks, depending on parts availability and scarcity.
Customs & Documentation
We prepare clear, order-specific documentation for every international shipment, including the commercial invoice, packing list and available product or compliance documents. Before dispatch, our logistics team confirms the consignee details, declared value, shipping terms and destination requirements with you. Tracking information is provided after shipment, helping your team prepare for import clearance with confidence.
Documents checked before dispatch · Shipment details confirmed · Global tracking provided
Payment
Payment is by bank wire only in RMB/CNY, GBP, EUR or USD. Amikon does not accept credit cards or provide credit terms. Cleared payment is required before shipment unless the written quotation expressly states otherwise.
Product Condition
Factory New These are new and current items that are procured directly from the manufacturer.
New In Sealed Package Parts are new. They have not been used and still have their original package seal intact.
New in Original Package These parts are new. The packages were not originally sealed by their original manufacturer.
Quantity
Mobile *
Country/Region *
E-mail *
Company
Content *
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Amikong please read our privacy policy.
  • 20+

    years in automation
  • ISO 9001

    certified quality system
  • 12 months

    amikon warranty
  • 2-hour reply

    from your account manager
  • Success Story

    solutions in action
PRODUCT DESCRIPTION

1SDA051266R1 Thermomagnetic molded-case circuit breaker

ABB 1SDA051266R1 is a SACE Tmax T3S 250 three-pole molded-case circuit breaker with a TMD 125 A thermomagnetic release. Its fixed construction and front power terminals are identified by the F F configuration, while the S breaking-capacity class provides 50 kA Icu at 415 V AC.

The thermal threshold adjusts from 0.7 to 1.0 times the 125 A trip rating, equivalent to 87.5 to 125 A, and the instantaneous magnetic threshold is fixed at 1250 A. The T3 frame has a 250 A uninterrupted-current rating, an 800 V insulation rating and an 8 kV impulse withstand rating.
ACTUAL APPLICATIONS

Application fields for 1SDA051266R1

ABB 1SDA051266R1 is a fixed three-pole T3S 250 breaker with a 125 A TMD release. Its low-voltage context includes buildings, electricity and transport. Suitability depends on the circuit voltage, fault level, selected thermal threshold and fitted terminal arrangement.
  • 01 · BUILDINGS

    Commercial Buildings and Public Urban Infrastructure

    Commercial premises, civic buildings and urban infrastructureResidential construction, public buildings and municipal infrastructure
  • 02 · POWER GENERATION

    Conventional Electricity and Renewable Power Generation

    Thermal electricity, hydroelectric power and renewable energyNuclear electricity, wind energy and solar power
  • 03 · TRANSPORT

    Rail Transport and Maritime Transport Networks

    Passenger railways, freight transport and urban transitMaritime transport, port logistics and coastal transport

Technical specifications for 1SDA051266R1

  • Product Model
    1SDA051266R1
  • Product Parameters
    Thermomagnetic molded-case circuit breaker
  • In stock
    10 units
  • Manufacturer
    ABB
  • Number of poles
    3
  • Frame rated uninterrupted current
    250 A
  • Trip-unit rated current
    125 A
  • Trip release
    TMD thermomagnetic
  • Thermal threshold adjustment
    0.7 to 1.0 x In (87.5 to 125 A)
  • Instantaneous magnetic threshold
    1250 A, fixed
  • Installation version
    Fixed (F)
  • Power terminals
    Front (F)
  • Icu at 380/400/415 V AC
    50 kA
  • Maximum AC service voltage
    690 V, 50/60 Hz
  • Rated insulation voltage
    800 V
  • Impulse withstand voltage
    8 kV
  • Utilization category
    A
  • Reference standard
    IEC 60947-2
  • Mechanical endurance
    25000 operations
View all additional

Alternative Names

1SDA051266R1 SACE Tmax T3S 250 Thermomagnetic molded-case circuit breaker
SYSTEM & REPLACEMENT CHECK

Information needed before ordering

Three direct checks to secure your system integration and minimize ordering risks.

Information

System integration Replacement check Manuals & support
SYSTEM INTEGRATION

Integrate 1SDA051266R1 within SACE Tmax T3S 250

Integrate the fixed three-pole T3S breaker using the front-terminal arrangement and the T3 mounting drawing. The basic fixed body measures 105 mm wide, 150 mm high and 70 mm deep; allow additional clearance for the actual terminal covers, barriers and connected conductors.
Select the thermal threshold for the connected circuit within 87.5 to 125 A. The TMD magnetic threshold is fixed at 1250 A and is not the adjustable magnetic release used on other Tmax configurations. Apply the manufacturer temperature-derating table when the ambient differs from its reference condition.
Check the prospective fault current against the T3S breaking-capacity table at the actual service voltage. The published 50 kA figure applies at 380/400/415 V AC and must not be carried over to 690 V. Confirm terminal hardware, tightening requirements and the approved switching test before energizing.

Features:

  • Number of poles: 3
  • Frame rated uninterrupted current: 250 A
  • SACE Tmax T3S 250
Use 1SDA051266R1 only within the documented SACE Tmax T3S 250 arrangement and applicable installation instructions.
INTERCHANGEABILITY

Replace 1SDA051266R1 within SACE Tmax T3S 250

Match 1SDA051266R1 to the complete T3S 250 TMD125 configuration, including three poles, fixed mounting and front terminals. A T3N frame, a four-pole version or a TMG generator release has a different order code and is not established as an interchangeable spare.
Retain the recorded thermal setting and review the fixed 1250 A magnetic threshold against the circuit design. A 250 A frame marking does not make this 125 A release a 250 A protective setting. Compare the installed accessories and terminal covers separately from the breaker body.
Use the T3 fixed-version drilling template to check the mounting footprint and door clearance. After isolation and replacement by qualified personnel, verify mechanical operation, the selected thermal setting and the site-approved circuit tests before returning the circuit to service.

Features:

  • Number of poles: 3
  • Frame rated uninterrupted current: 250 A
  • SACE Tmax T3S 250
Use 1SDA051266R1 only within the documented SACE Tmax T3S 250 arrangement and applicable installation instructions.
DOCUMENTATION STATUS

Browse the Manuals, Datasheets, Official Documents, Links

Important Notice: The linked files are Amikong-hosted reference documents. Match their product identity and scope to the supplied assembly, and consult the applicable manufacturer instructions before use. Accessories and additional documents are included only when expressly listed in the quotation.

Features:

  • Exact-model technical data for 1SDA051266R1
  • Document applicability checked against the complete identity
  • Directory links by subcategory and brand
Documentation for 1SDA051266R1 must match the installed product identity and supplied configuration.

Also searched as

Important notice

Manuals, software, firmware, cables, calibration data and accessories are included only when listed in the quotation. AMIKON is an independent supplier and is not affiliated with or authorised by the manufacturer.
This content has been produced using multiple sources. Takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
BUYER INFORMATION

Commercial terms without hidden steps

Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • 01

    Shipping & delivery

    Dispatch
    Eligible stock: same / next day
    Carriers
    DHL, FedEx or UPS
    Ship from
    Xiamen, China
    Product size
    10.50 x 15.00 x 7.00 cm
    Net weight
    1.50 kg
  • 02

    Payment & customs

    Payment
    Bank transfer (T/T)
    Currencies
    USD · EUR · GBP · RMB
    Credit cards
    Not accepted
    HS reference
    8536200000
    Origin
    Italy
  • 03

    Warranty & returns

    Warranty
    12 months from AMIKON
    Inspection
    Label, condition and packing checks
    Returns
    Prior RMA authorisation required
    Compatibility
    Confirm before order
    OEM warranty
    Does not apply
Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • Part checked

    Full suffix recorded
  • Condition checked

    Label and appearance
  • Packing checked

    Antistatic protection
  • Tracking supplied

    Established couriers
  • Sandy Lin

    Dedicated account manager · 15+ years
FREQUENTLY ASKED QUESTIONS

Questions buyers ask about 1SDA051266R1

Direct answers about identity, compatibility, stock, warranty, payment and shipping.
  • Is the 250 A frame also the installed trip rating?

    1SDA051266R1: No. The T3 frame is rated 250 A, but this order contains a 125 A TMD release. Its thermal threshold adjusts from 87.5 to 125 A.
  • Can the instantaneous magnetic setting be adjusted?

    1SDA051266R1: The magnetic threshold is fixed at 1250 A for this TMD125 order. It must not be treated as an adjustable TMA or magnetic-only release.
  • Does 50 kA apply at every operating voltage?

    1SDA051266R1: No. The S-class Icu is 50 kA at 380/400/415 V AC. Use the voltage-specific T3S table for another service voltage.
  • Which mounting and power-terminal version is supplied?

    1SDA051266R1: The order table identifies a fixed three-pole breaker with front terminals, abbreviated F F. Plug-in, rear-terminal and four-pole assemblies require separate identification.
  • Can a T3N125 replace the S-class breaker?

    1SDA051266R1: A shared 125 A release rating is insufficient. Compare the voltage-specific breaking capacity, installation version, terminals and fitted accessories before considering a substitution.
  • What should be tested after fitting the TMD breaker?

    1SDA051266R1: Verify mechanical switching, the recorded thermal adjustment, terminal security and the approved circuit checks. Confirm the fixed magnetic setting remains suitable for the circuit design.
  • What information helps purchasing identify this fixed three-pole spare?

    1SDA051266R1: State 1SDA051266R1, T3S 250 TMD125, three poles and F F terminals, plus quantity and photographs of any fitted auxiliaries or covers.
  • What distinguishes the delivered breaker from a bare 250 A frame?

    1SDA051266R1: Match the full label, 125 A release, three-pole body and front terminals to the order. Check accessory scope and damage before accepting the delivery.
READY TO VERIFY YOUR PART?

Get a 1SDA051266R1 quote with price, lead time and revision check.

Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: Amikon Limited sells new and surplus products and develops channels for purchasing such products. Amikon Limited is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because Amikon Limited is not an authorized distributor of this product, the Original Manufacturer's warranty does not apply. Amikon Limited is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.