ACS880 frequency converter drive board
Operating Voltage: 24 Vdc
Analog Inputs: 0–10 V or 4–20 mA
Operating Temperature: -10°C to +50°C
Humidity: 5–95% non-condensing
Output Power: 160 kW (215 HP) at 400 V AC.
Output Current: 302 A
Input: 380–480 V AC, 3-phase (±10%), 50/60 Hz.
Output: 0–480 V AC
Efficiency: ≥97% (typical at full load)
Control I/O: 5x analog inputs (2x 0–10 V / 0–20 mA)
Switching Frequency: 1–8 kHz
Input Voltage: 24 VDC (±10%)
Analog Inputs: 0–10 VDC / 4–20 mA
Fieldbus Support: PROFIBUS DP
Operating Temperature: -25°C to +55°C (-13°F to +131°F).
Humidity: Up to 95% non-condensing
Input Voltage: 24 VDC (±10%)
Analog Inputs: 0–10 VDC / 4–20 mA
Fieldbus Support: PROFIBUS DP
Operating Temperature: -25°C to +55°C (-13°F to +131°F).
Humidity: Up to 95% non-condensing
Input Voltage: 24 VDC (±10%)
Analog Inputs: 0–10 VDC or 4–20 mA
Operating Temperature: -25°C to +55°C (-13°F to +131°F)
Humidity: Up to 95% non-condensing.
Vibration Resistance: 5–150 Hz
Input Voltage: 24 VDC (±10%)
Analog Inputs: 0–10 VDC or 4–20 mA
Operating Temperature: -25°C to +55°C (-13°F to +131°F).
Humidity: Up to 95% non-condensing.
Vibration Resistance: 5–150 Hz
RAM: Typically 512 MB to 1 GB
Supply Voltage: 24 VDC (±10%).
Power Consumption: Typically 5–10 W
Operating Temperature: -20°C to +70°C (-4°F to +158°F).
Storage Temperature: -40°C to +85°C (-40°F to +185°F).
Humidity: 5–95% non-condensing
RAM: Typically 512 MB to 1 GB
Flash Memory: 2–4 GB
Supply Voltage: 24 VDC (±10%).
Power Consumption: Typically 5–10 W
Operating Temperature: -20°C to +70°C (-4°F to +158°F).
Storage Temperature: -40°C to +85°C (-40°F to +185°F).
Humidity: 5–95% non-condensing
24 binary outputs with enclosed relays (NO contacts)
Current carrying capacity of the relays: max. 1 A
Channel-by-channel isolation of the outputs
Module is capable of redundant operation
Monitoring of the module
Counter for switching cycles (channel by channel)
16 analog outputs, output signal 0/4 ... 20 mA,
channel-by-channel configuration
Load: max. 700 Ohm
Monitoring of loads
Channel-by-channel isolation of outputs
Module is capable of redundant operation
Digital communication with field devices according to
HART protocol (Version 5.0 / 5.1)
Monitoring of modules
32 binary inputs divided into two groups each with 16 inputs
Process current circuits in accordance
with EN 50020 with type of protection EEx ib IIC
Combined installation possible with
"Non-Ex-modules" in one module sub-rack
Signal recording with 1 ms time resolution
Monitoring of module
Central galvanic separation of system inputs
Group-set filter time
Module is capable of redundancy
32 binary inputs divided into two groups each with 16 inputs
Process current circuits in accordance
with EN 50020 with type of protection EEx ib IIC
Combined installation possible with
"Non-Ex-modules" in one module sub-rack
Signal recording with 1 ms time resolution
Monitoring of module
Central galvanic separation of system inputs
Group-set filter time
Module is capable of redundancy
Data Rate: Up to 12 Mbps
Isolation:1500 V AC
Power Supply: 24 V DC (±10%)
Power Consumption: Typically 5–10 W
Fieldbus Port: 9-pin D-sub or M12 for PROFIBUS
Operating Temperature:
-25°C to +70°C (-13°F to +158°F)
Humidity: 5–95% noncondensing
Output Channels:32
Output Type SINK: (Open Drain)
Load Current :0.1 A per channel (Max)
On-State Voltage 0v VDC (load current @:0.1A max
Off-State Voltage:24 V (typ),
Off-State Leak Current:100 µA (max)
Turn-On/Turn-Off Time:10 ms (max)
Power supply:24V DC
Rated Current:55mA at 24V
Power Consumption:1.32W at 20mA
Power/DCS to Field:1500 VAC
DCS side connections:
37 pin DSUB connector on CC-UGIA01
Voltage Input:24V DC
Interface to DCS:4 to 20mA with HART
Power supply 24V DC
Rated Current 55mA at 24V
Power Consumption 1.32W
Power/DCS to Field 1500 VAC
DCS side connections 37 pin
DSUB connector on CC-UGIA01
Voltage Input 24V DC
Current Input 4 to 20mA with HART,
CC-UGAI01 in sink mode.
Open wire current <150uA
Type: LCD or TFT color touchscreen
Operating Voltage: 24 VDC (±10%) or 110–230 VAC
Power Consumption: 10–20 W
Operating Temperature: -10°C to +55°C
Storage Temperature: -40°C to +70°C
Humidity: 5–95% (non-condensing)
Model: SDCS-PIN-H41
Part Number: 3ADT320600R1501
Pulse Voltage: 5–24 V DC
Isolated Pulse Voltage: Typically 10–30 V
Output Current: 1–2 A
Primary-to-Secondary Isolation: ≥2500 V AC
Insulation Resistance: >100 MΩ
Channels: 16 digital channels
Input Type: 24 VDC
Isolation:500 VDC
Update Rate: ≤10 ms
Power Consumption: ≤5 W
Operating Temperature: -40°C to +70°C (-40°F to +158°F).
Humidity: 5–95% non-condensing.