Voltage: 24V DC (nominal).
Current Consumption: Typically 100 mA at 24V DC.
Power Requirement for Operation: Minimal, typically < 3W
Range: -10°C to +60°C
Storage Temperature: -40°C to +85°C
Operating: 5% to 95% non-condensing
Number of outputs 4-channel, module isolation
Output voltage 24 V DC
Output voltage drop 1 V maximum
External power supply rating 24 V DC, 10 A minimum
Maximum leak current at output offstatus 1.6 mA
Output format Current source
Maximum load current 2 A/output line
Minimum load current 100 mA
Load resistance range 12 to 240 Ω
Maximum lamp load (*1) 1 A/output line
Output response time 30 ms maximum
Number of outputs 4-channel, module isolation
Output voltage 24 V DC
Output voltage drop 1 V maximum
External power supply rating 24 V DC, 10 A minimum
Maximum leak current at output offstatus 1.6 mA
Output format Current source
Maximum load current 2 A/output line
Minimum load current 100 mA
Load resistance range 12 to 240 Ω
Maximum lamp load (*1) 1 A/output line
Output response time 30 ms maximum
Number of input channels 16 channels, module isolation
Rated input range 4 to 20 mA
Permissible input range 0 to 25 mA
Input impedance during Power-OFF 500 kΩ minimum
Data update frequency 40 ms
Temperature drift ±16 µA/10 °C
Number of input channels 16 channels, module isolation
Rated input range 4 to 20 mA
Permissible input range 0 to 25 mA
Input impedance during Power-OFF 500 kΩ minimum
Data update frequency 40 ms
Temperature drift ±16 µA/10 °C
Number of output channels 8 channels, module isolation
Rated output range 4 to 20 mA
Maximum range of guaranteed precision 1.25 to 23 mA
Output range 1.25 to 23 mA
Allowable load resistance @ rated range 230 to 600 Ω
Accuracy ±48 µA
Data update frequency 40 ms
Temperature drift ±16 µA/10 ºC
Withstand voltage 1.5 kV AC between output signal and system for 1 minute
Number of outputs 8-channel, module isolation
Output voltage 24 V DC
Output voltage drop 1 V maximum
External power supply rating 24 V DC, 5 A minimum
Maximum leak current at output offstatus 1.6 mA
Output format Current source
Maximum load current 0.6 A/output line
Minimum load current 35 mA
Load resistance range 40 to 685 Ω
Output response time 30 ms maximum
Number of outputs 16-channel, module isolation
Output voltage 24 V DC
Output voltage drop 1 V maximum
External power supply rating 24 V DC, 3.4 A minimum
Maximum leak current at output off status 1.6 mA
Output format Current source
Maximum load current 0.2 A/output line
Minimum load current 35 mA
Load resistance range 120 to 685 Ω
Output response time 30 ms maximum
Number of outputs 8-channel, module isolation
Output voltage 24 V DC
Output voltage drop 1 V maximum
External power supply rating 24 V DC, 5 A minimum
Maximum leak current at output offstatus 1.6 mA
Output format Current source
Maximum load current 0.6 A/output line
Minimum load current 35 mA
Load resistance range 40 to 685 Ω
Output response time 30 ms maximum
100-120 V AC power supply
24 V DC power supply
Standard Type (-20 to 40 °C)
(with ISA Standard G3 )
Dual-redundant power supply
Wide range temperature (-20 to 70 °C)
type (with Fan unit and ISA Standard G3)
Voltage Current
Thermocouple
Voltage: ±100mV to ±10V, Current: 4-20mA
Output Range
Voltage: 0-10V, Current: 4-20mA
Accuracy: ±0.1% of full scale
Response Time: ≤ 250 ms
Power Supply: 24V DC
Isolation Voltage: 1500V AC
Operating Temperature: -10°C to +55°C
Number of outputs 4-channel, module isolation
Output voltage 24 V DC
Output voltage drop 1 V maximum
External power supply rating 24 V DC, 10 A minimum
Maximum leak current at output offstatus 1.6 mA
Output format Current source
Maximum load current 2 A/output line
Minimum load current 100 mA
Maximum lamp load (*1) 1 A/output line
Output response time 30 ms maximum
Number of outputs 8-channel, module isolation
Output voltage 24 V DC
Output voltage drop 1 V maximum
External power supply rating 24 V DC, 5 A minimum
Maximum leak current at output offstatus 1.6 mA
Output format Current source
Maximum load current 0.6 A/output line
Minimum load current 35 mA
Load resistance range 40 to 685 Ω
Output response time 30 ms maximum
Number of outputs 8-channel, module isolation
Output voltage 24 V DC
Output voltage drop 1 V maximum
External power supply rating 24 V DC, 5 A minimum
External power supply 24 V DC +20 %/–10 %
Output format Current source
Maximum load current 0.6 A/output line
Minimum load current 35 mA
Load resistance range 40 to 685 Ω
Output response time 30 ms maximum
Memory Size:1008 kB
Memory Type User Data:RAM
Controller Processing Time:0.0002 ms
Number of Digital Inputs:6
Number of Digital Outputs:4
Number of Digital Configurable I/Os:0
Input Voltage Type:DC
Degree of Protection:IP20
Rated Voltage (Ur):24 V DC
Supply Voltage:20.4 … 28.8 V DC
Voltage Rating: 400–690 VAC ±10%
Input Current: 1,100 A (maximum)
Frequency Range: 0–1000 Hz
Operating Temperature:-20°C to +50°C
Storage Temperature: -40°C to +70°C.
Humidity: 5% to 95% (non-condensing)
Memory Size:142 kB
Memory Type User Data:RAM
Controller Processing Time:0.00008 ms
Analog Inputs:2
Analog Outputs:1
Number of Digital Inputs:6
Number of Digital Outputs:6
Number of Digital Configurable I/Os:0
Input Voltage Type:DC
Rated Voltage (Ur):24 V DC
Supply Voltage:20.4 … 28.8 V DC
Voltage Rating:400V AC
Current Rating:45A at 400V
Frequency Range:0-500 Hz
Input Power: 3-phase 400V AC
Control Inputs/Outputs:0-10V or 4-20mA
Operating temperature range: Typically -10°C to +50°C
Storage temperature range: -40°C to +70°C
24V DC for logic power
230V to 690V AC
Approximately 10-20W
0 Hz to 200 Hz
Standard range: -10°C to +50°C
Storage Temperature:-40°C to +85°C
5% to 95% RH, non-condensing