3300 XL 11 mm Reverse MountProbe
330705-02-18- CC-DD-EE 3/8-24 UNFthreads
909.0 meters (29.5 feet)
02 Miniature ClickLoc coaxialconnector
00 Not required
Control Field exciter board
Supply Voltage: 24 VDC
Power Consumption: ~10–20 W
Voltage Range: 0–250 VDC
Current Range: 0–20 A
Accuracy: ±0.5% of full scale
Input-to-Output Isolation: 2500 VAC
Analog Inputs: 4–20 mA / 0–10 V
ACM+ Advanced Control Module
39ACM28AEN
DISCONTINUED
CONTROL MODULE ADVANCED APACS .6AMP 24VDC
Tariff Code: 8537109060
Country of Origin: United States
I/O pack
CARD
INPUT/OUTPUT PACK
PROTECTION TYPE
FOR MARK VIE TURBINE CONTROL SYSTEM
2 ETHERNET PORTS
POWER SUPPLY
LOCAL PROCESSOR
DATA ACQUISITION BOARD
Micro Memory Card - 512 KB
MEMORY CARD
SIMATIC S7
FOR S7-300/C7/ET 200
3V NFLASH
512KB
REPLACES: 6ES7953-8LJ00-0AA0 AND
6ES7953-8LJ30-0AA0
3300 XL 8 mm Proximity Probes
330104 3300 XL 8 mm Probe
M10 x 1 thread,with armor
Minimum unthreaded length: 0 mm
Minimum case length: 60 mm
10 1.0 meter (3.3 feet)
02 Miniature coaxial ClickLocconnector
standard cable
00 Not required
Valve Amplifier Card
WV60RGC2
Valve Amplifier Card
VT-VRPA 2-537-10/V0/RTP
0811405120
24 VDC
55 VA MAX

Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.