
























Pcb board
1 PORT CHANNEL
Operating Temperature Range: -40°C to +70°C.
Power Consumption: Maximum of 5W
Data Transfer Rate: Up to 400 Mbps
Digital I/O Channels: Provides 32 digital
PROFIBUS INTERFACE CARD
PROFIBUS INTERFACE CARD
1 PORT CHANNEL
Operating Temperature Range: -40°C to +70°C.
Power Consumption: Maximum of 5W
Data Transfer Rate: Up to 400 Mbps
Digital I/O Channels: Provides 32 digital
Current Input Module
Number of input channels
16-channel input, isolated
Input signal 4 to 20 mA
Allowable input current 24 mA
Accuracy ±0.1% of full scale
Data refresh cycle 10 ms
Transmitter power supply 24.0 to 25.5 V
Temperature drift Max. ±0.01%/°C
Current Input Module
Number of I/O channels
8-channel input, isolated channels
I/O signal 4 to 20 mA
Allowable input current 25 mA
Accuracy ±16 µA
Data update period 10 ms
Temperature drift ±16 µA/10 °C
Maximum currentconsumption
360 mA (5 V DC), 450 mA (24 V DC)
ELECTRONIC MODULE
SIMATIC DP
ELECTRONIC MODULE
ET200S: 2AI HIGH SPEED I2WIRE
0 - 20MA, 4 - 20MA, 15BIT
15 MM WIDTH,FOR 2-WIRE
TRANSDUCER,CYCLE TIME OF
THE MOD.: 0.1MS,
WITH LED SF (GROUP FAULT)
Isolation Module 4-Port Benefits
High-Speed 1 MS/s 16-bit Isolation Module
(4 ch) High Noise Immunity
Suitable for testing and long-term monitoring
for power generators and multi-output power supplies.
Provides dynamic analysis of multi-channel
data recording applications.
Applicable to DL350 and DL850 series
Auto Transfer Switch & Mains Control Module
CONTINUOUS VOLTAGE RATING
8 V to 35 V continuous
CRANKING DROPOUTS
Able to survive 0 V for 50 mS,
providing supply was at least 10 V
before dropout and supply recovers to 5 V.
This is achieved without the need for internal batteries
MAXIMUM OPERATING CURRENT
460 mA at 12 V, 245 mA at 24 V
MAXIMUM STANDBY CURRENT
375 mA at 12 V, 200 mA at 24 V
CHARGE FAIL/EXCITATION RANGE
0 V to 35 V
Failure Load Share Control Modulee
CONTINUOUS VOLTAGE RATING
5 V to 35 V continuous
CRANKING DROPOUTS
Able to survive 0 V for 100 mS,
providing supply was at least 10 V
before dropout and supply recovers to 5 V.
This is achieved without the need for internal batteries
MAXIMUM OPERATING CURRENT
530 mA at 12 V, 280 mA at 24 V
MAXIMUM STANDBY CURRENT
320 mA at 12 V, 160 mA at 24 V
CHARGE FAIL/EXCITATION RANGE
0 V to 35 V
Synchronising & Load Sharing Auto Start Control Module
CONTINUOUS VOLTAGE RATING
8 V to 35 V continuous
CRANKING DROPOUTS
Able to survive 0 V for 50 mS,
providing supply was at least 10 V
before dropout and supply recovers to 5 V.
This is achieved without the need for internal batteries
MAXIMUM OPERATING CURRENT
460 mA at 12 V, 245 mA at 24 V
MAXIMUM STANDBY CURRENT
375 mA at 12 V, 200 mA at 24 V
CHARGE FAIL/EXCITATION RANGE
0 V to 35 V
Auto Mains (Utility) Failure Control Module
CONTINUOUS VOLTAGE RATING
8 V to 35 V Continuous
Able to survive 0 V for 50 mS
providing supply was at least 10 V
before dropout and supply recovers to 5 V
This is achieved without the need for internal batteries
LEDs and backlight will not be maintained during cranking
MAXIMUM OPERATING CURRENT
85 mA at 12 V, 96 mA at 24 V
MAXIMUM STANDBY CURRENT
51 mA at 12 V, 47 mA at 24 V
Auto Mains (Utility) Failure Control Module
Able to survive 0 V for 50 mS
providing supply was at least 10 V
efore dropout and supply recovers to 5 V
This is achieved without the need for internal batteries.
LEDs and backlight will not be maintained during cranking
CONTINUOUS VOLTAGE RATING
8 V to 35 V Continuous
MAXIMUM OPERATING CURRENT
85 mA at 12 V, 96 mA at 24 V
MAXIMUM STANDBY CURRENT
51 mA at 12 V, 47 mA at 24 V
MAXIMUM SLEEP CURRENT
35 mA at 12 V, 32 mA at 24 V
MAXIMUM DEEP SLEEP CURRENT
<10 uA at 12 V, <10 uA at 24 V
Auto Mains (Utility) Failure Control Module
CONTINUOUS VOLTAGE RATING
8 V to 35 V Continuous
5 V for up to 1 Minute
CRANKING DROPOUTS
Able to survive 0 V for 100 mS,
providing supply was at least 10 V
before dropout and supply recovers to 5 V.
This is achieved without the need for internal batteries
MAXIMUM OPERATING CURRENT
510 mA at 12 V, 240 mA at 24 V
MAXIMUM STANDBY CURRENT
330 mA at 12 V, 160 mA at 24 V
CHARGE FAIL/EXCITATION RANGE
0 V to 35 V
Auto Mains (Utility) Failure Control Module
Operating Voltage Range: 8 V to 35 V
Cranking Dropout:
Able to withstand 0 V for 50 ms,
provided the supply was at least 10 V
before the dropout and recovers to 5 V
afterward. No internal battery is required.
Maximum Operating Current:
100 mA at 12 V, 105 mA at 24 V
Maximum Standby Current:
60 mA at 12 V, 55 mA at 24 V
Maximum Sleep Current:
40 mA at 12 V, 35 mA at 24 V
Generator Control Module
Back-lit icon LCD display
Front panel editing
LED and LCD alarm indication
Power Save mode
CAN and Magnetic Pick-up/Alt.
versions available (specify on
ordering)
PC configurable
6 Digital inputs
4 Outputs (2 configurable on
Magnetic Pick up/Alt., 4 configurable on CAN version)
Configurable timers and alarms
Alternative configuration
Remote Start input
Generator voltage display
ELECTRONIC MODULE
SIMATIC DP
ELECTRONIC MODULE FOR ET 200S
2 AI STAND.I-2DMU 15 MM WIDE
4 .. 20MA; 13 BIT FOR
2-WIRETRANSDUCER CYCLE
TIME 65 MS/CHANNEL WITH LED SF
POWER MODULE
SIMODRIVE 611
POWER MODULE
2 AXES, 50A
INTERNAL HEAT DISSIPATION
RATED MOTOR CURRENTS:
FEED = 18 A MAIN
SPINDEL = 24 A
Swappable lens with C-mount connection
suitability for use Swappable lens with C-mount connection
suitability for operation lens for MV440
mechanical datacolor black
design, dimensions and weight
sheight 37.2 mm
diameter 29.5 mm
Kinetix 300 Servo Drive
120 Volts Doubler Mode:Yes
Continuous Output Current (0-peak):5.7 Amperes
Integrated AC (EMC) Line Filter:No
Input Voltage:120/240 Volts (AC), 1 Phase
Power Rating:800 W
Part Number/Catalog No.:2097-V31PR2-LM
Safe Torque-Off:Yes

Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.