Bently Nevada 190501-10-00-00
· Product image is representative; revision or series may vary. Contact us to request a specific version.
Ships by Tuesday, September 15

190501-10-00-00

Velomitor CT Velocity Transducer

Shipping Information

  • For inventory products, we support same day shipping upon payment.
  • For urgent needs, we offer same-day shipping on most items for orders placed before 2:00 PM UTC+8 Simply mention your preferred next-day shipping when place the order, and your order will be prioritized to minimize downtime.
  • For indent items, typical turnaround is 1-3 weeks, depending on parts availability and scarcity.
Customs & Documentation
We prepare clear, order-specific documentation for every international shipment, including the commercial invoice, packing list and available product or compliance documents. Before dispatch, our logistics team confirms the consignee details, declared value, shipping terms and destination requirements with you. Tracking information is provided after shipment, helping your team prepare for import clearance with confidence.
Documents checked before dispatch · Shipment details confirmed · Global tracking provided
Payment
Payment is by bank wire only in RMB/CNY, GBP, EUR or USD. Amikon does not accept credit cards or provide credit terms. Cleared payment is required before shipment unless the written quotation expressly states otherwise.
Product Condition
Factory New These are new and current items that are procured directly from the manufacturer.
New In Sealed Package Parts are new. They have not been used and still have their original package seal intact.
New in Original Package These parts are new. The packages were not originally sealed by their original manufacturer.
Quantity
Mobile *
Country/Region *
E-mail *
Company
Content *
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Amikong please read our privacy policy.
  • 20+

    years in automation
  • ISO 9001

    certified quality system
  • 12 months

    amikon warranty
  • 2-hour reply

    from your account manager
  • Success Story

    solutions in action
PRODUCT DESCRIPTION

190501-10-00-00 measures slow-fan casing vibration

The 190501-10-00-00 measures low-frequency casing vibration on cooling-tower and air-cooled heat-exchanger fan assemblies operating at or above 90 rpm. It also detects vibration generated by the fan motor and speed reducer.

The selected mounting code 10 supplies an M6x1-to-M6x1 plate stud with a 3/8-in 24 adapter. Connection code 00 specifies a MIL-C-5015 interface; final code 00 specifies no agency approvals. Do not apply the family hazardous-area certifications to this unapproved configuration.
ACTUAL APPLICATIONS

Where 190501-10-00-00 measures fan-system vibration

Bently Nevada describes casing measurements on cooling-tower and air-cooled heat-exchanger fans, including motor and speed-reducer vibration. A suitable structural transmission path is essential.
  • 01 · COOLING-TOWER FANS

    Observe low-speed fan casing motion

    Apply the low-frequency velocity transducer to cooling-tower fan assemblies operating at or above 90 rpm. Select a bearing-housing or casing location that transmits the vibration of interest, and assess the signal within the documented frequency-response limits.
  • 02 · AIR-COOLED EXCHANGERS

    Measure exchanger fan vibration

    Use the documented casing-measurement approach on air-cooled heat-exchanger fan assemblies. Evaluate whether the mechanical path carries rotor vibration to the sensor position; an unsuitable mounting point can weaken the response or give an unrepresentative signal.
  • 03 · FAN DRIVE TRAINS

    Assess motor and reducer vibration

    The transducer also measures vibration frequencies generated by the fan motor and speed reducer. Review their frequency content against the sensor response and operating-range graphs, including the stated reduction in range from sufficiently strong high-frequency vibration.

Technical specifications for 190501-10-00-00

  • Product Model
    190501-10-00-00
  • Product Parameters
    Velomitor CT Velocity Transducer
  • In stock
    1 unit
  • Manufacturer
    Bently Nevada
  • Mounting hardware option
    10: M6x1 plate stud with 3/8-in 24 adapter
  • Connection option
    00: MIL-C-5015 connection interface
  • Agency approval option
    00: No approvals
  • Sensitivity
    3.94 mV/mm/s (100 mV/in/s), +/-5%
  • Frequency response
    3-900 Hz +/-1 dB; 1.5-1000 Hz +/-3 dB
  • Velocity range
    63.5 mm/s peak; high-frequency limits apply
  • Amplitude linearity
    +/-2% to 63.5 mm/s peak
  • Output bias voltage
    10.1 V DC +/-1.0 V; Pin A relative to Pin B
  • Dynamic output impedance
    Less than 400 ohm, typical
  • Transverse response
    Less than 5% of axial sensitivity
  • Operating temperature
    -40 to +85 deg C
  • Storage temperature
    -40 to +100 deg C
  • Case material
    316L stainless steel
  • Mounting torque
    4.5 N m +/-0.6 N m
  • Humidity limit
    100% condensing; non-submerged
View all additional

Alternative Names

190501-10-00-00 190501 Velomitor CT Cooling-tower piezo-velocity transducer
SYSTEM & REPLACEMENT CHECK

Information needed before ordering

Three direct checks to secure your system integration and minimize ordering risks.

Information

System integration Replacement check Manuals & support
VELOMITOR CT MEASUREMENT INTEGRATION

Match the mounting point and velocity input

The 190501-10-00-00 measures low-frequency casing vibration on cooling-tower and air-cooled heat-exchanger fan assemblies operating at or above 90 rpm. It also detects vibration generated by the fan motor and speed reducer.
The two-pin MIL-C-5015 interface and the M6 plate stud with 3/8-in 24 adapter are fixed by this order. Verify the complete cable arrangement, input scaling and the mounting point against the actual installation.
Use the specified sensitivity and response tolerances when assessing the measurement channel. The internal electronics are isolated from the case; motion from base to top produces positive Pin A voltage relative to Pin B. This order has no agency approvals.

Features:

  • Match the plate stud and threaded adapter
  • Confirm the MIL-C-5015 cable connection
  • Evaluate casing-to-sensor vibration transmission
The 190501-10-00-00 requires the mounting, connection and measurement limits to be checked before system integration and commissioning.
INTERCHANGEABILITY

Verify the complete replacement identity before commissioning

An identical family name does not establish replacement suitability. Compare the complete 190501 order code, mounting hardware, connector, required cable and agency approval requirement before replacing an installed transducer.
Record the original sensor position and installation arrangement. Check that the M6 plate stud and adapter fit the intended mounting point and use the documented mounting torque. Do not substitute this no-approval configuration where certified equipment is required.
After installation, evaluate the measurement against the machine condition and the published response limits. The downloadable technical extract is not complete operation manual 125389-01; obtain that manual for procedures and service details outside the data sheet.

Features:

  • Check all three order-option groups
  • Retain the appropriate measurement location
  • Review the response and mounting after replacement
The 190501-10-00-00 requires replacement verification of mounting hardware, cable connection, response limits and approval needs before commissioning.
DOCUMENTATION STATUS

Browse the Manuals, Datasheets, Official Documents, Links

Important Notice: The Manufacturer's Manual download is a manufacturer technical-data extract, not complete operation manual 125389-01. The installation guide contains only supported data-sheet information. Accessories are included only when specified in the quotation.

Features:

  • Source: Bently Nevada 141636-01 Rev. Y (05/14), user-authorized reproduction
  • Software licensing and project backups remain the customer's responsibility
  • Accessories are supplied only when listed in the quotation
Documentation for the 190501-10-00-00 is a technical-data extract rather than a complete operation manual; confirm manual availability in the written quotation.

Important notice

Manuals, software, firmware, cables, calibration data and accessories are included only when listed in the quotation. AMIKON is an independent supplier and is not affiliated with or authorised by the manufacturer.
This content has been produced using multiple sources. Takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
BUYER INFORMATION

Commercial terms without hidden steps

Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • 01

    Shipping & delivery

    Dispatch
    Eligible stock: same / next day
    Carriers
    DHL, FedEx or UPS
    Ship from
    Xiamen, China
    Packed size
    20.5 × 22.4 × 3.3 cm
    Shipping weight
    0.10 kg
  • 02

    Payment & customs

    Payment
    Bank transfer (T/T)
    Currencies
    USD · EUR · GBP · RMB
    Credit cards
    Not accepted
    HS reference
    9031809090
    Origin
    USA
  • 03

    Warranty & returns

    Warranty
    12 months from AMIKON
    Inspection
    Label, condition and packing checks
    Returns
    Prior RMA authorisation required
    Compatibility
    Confirm before order
    OEM warranty
    Does not apply
Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • Part checked

    Full suffix recorded
  • Condition checked

    Label and appearance
  • Packing checked

    Antistatic protection
  • Tracking supplied

    Established couriers
  • Sandy Lin

    Dedicated account manager · 15+ years
FREQUENTLY ASKED QUESTIONS

Questions buyers ask about 190501-10-00-00

Direct answers about identity, compatibility, stock, warranty, payment and shipping.
  • Can this configuration be used where an approved sensor is required?

    Its final 00 option specifies no agency approvals. Do not apply the family certification statements to this exact order. An installation requiring certification needs a suitably approved configuration and its applicable documents.
  • What mounting hardware should accompany option 10?

    The ordering table specifies an M6x1-to-M6x1 plate stud with a 3/8-in 24 adapter. Check both the plate stud and adapter when comparing the delivered assembly with the existing mounting point.
  • Does connection option 00 include the 32-foot cable?

    No. Option 00 specifies the MIL-C-5015 connection interface. The data sheet separately identifies option 99 as the version supplied with a 32-foot cable; cable supply must therefore be confirmed in the quotation.
  • Why can a suitable frequency range still produce an unrepresentative casing reading?

    Rotor vibration must be transmitted to the bearing housing, casing and sensor location. The manufacturer warns that an unsuitable mounting location or improper installation can degrade response or generate signals that do not represent machine vibration.
  • Which polarity applies when the transducer moves from its base toward its top?

    Pin A becomes positive with respect to Pin B for base-to-top velocity. Use the documented polarity when checking the connected measurement channel.
  • Are the two frequency-response ranges interchangeable acceptance limits?

    No. The 3.0-900 Hz range has a +/-1 dB tolerance, whereas 1.5 Hz-1.0 kHz uses +/-3 dB. Select the applicable tolerance when assessing the vibration frequencies of a slow fan and its drive train.
  • Can strong vibration above 1 kHz affect the stated velocity range?

    Yes. The data sheet notes that vibration components exceeding 10 g peak above 1 kHz can significantly reduce the 63.5 mm/s peak velocity range. Review the complete operating-range graphs for the measurement task.
  • Do the three downloadable files include complete operation manual 125389-01?

    No. They are an Amikon parameter summary, an explicitly identified manufacturer data-sheet extract and a limited installation guide based on that same source. Obtain complete manual 125389-01 for operating or service procedures absent from the data sheet.
READY TO VERIFY YOUR PART?

Get a 190501-10-00-00 quote with price, lead time and revision check.

Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: Amikon Limited sells new and surplus products and develops channels for purchasing such products. Amikon Limited is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because Amikon Limited is not an authorized distributor of this product, the Original Manufacturer's warranty does not apply. Amikon Limited is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.
Product

Product Browsing History