Bently Nevada TK3-2E
Bently Nevada TK3-2E
Bently Nevada TK3-2E
· Product image is representative; revision or series may vary. Contact us to request a specific version.

TK3-2E

TK3 Proximity System Test Kit

Require for Quote:

Need more help? You may also find the answer in our FAQ section

Shipping Information

  • For inventory products, we support same day shipping upon payment.
  • For urgent needs, we offer same-day shipping on most items for orders placed before 2:00 PM UTC+8 Simply mention your preferred next-day shipping when place the order, and your order will be prioritized to minimize downtime.
  • For indent items, typical turnaround is 1-3 weeks, depending on parts availability and scarcity.

Technical specifications for TK3-2E

  • Product Model
    TK3-2E
  • Spare Model
    14700-02A
  • Product Parameters
    TK3 Proximity System Test Kit
  • Tariff Code
    8537101190
  • Country of origin
    USA
  • Place of shipment
    Xiamen, China
  • In stock
    1 unit
  • Estimated Shipping Size
    28.5x20x23cm
  • Manufacturer
    Bently Nevada
  • Weight
    6.02 kg
  • Power Electric
    95- 125 Vac, 50/60 Hz, 1A minimum / 190 - 250 Vac, 50/60 Hz, 1A minimum
  • Inputs Air
    90 psi (6.2 bar) maximum
  • Vibration Amplitude Range
    50 μm to 254 μm (2 to 10 mils) peak-to-peak
  • Maximum Speed Electric
    0 to 10,000 cpm +2,500 cpm
  • Air
    0 to 5,000 cpm +1,000 cpm

Description

The TK-3 Proximity System Test Kit simulates shaft vibrationand position for calibrating Bently Nevada monitors. It verifiesthe operating condition of the monitor readouts as well as thecondition of the proximity transducer system. A properlycalibrated system ensures that the transducer inputs and theresulting monitor readings are accurate.

Vibration monitors are calibrated using the motor-drivenwobble plate. A swing-arm assembly located over thewobble plate holds the proximity probe in place. Thisassembly uses a universal probe mount, identical to thatused with the spindle micrometer assembly. By using theabsolute scale factor of the proximity probe in conjunctionwith a multimeter, the user adjusts the probe to find aposition where the desired amount of mechanical vibration(as determined by peak-to-peak DC voltage output) ispresent. No oscilloscope is needed.

Alternative Names

TK3 2E TK3/2E TK3

Information

Overview Manuals User guide Product Applications Initial Instrument Bench Setup & Power Configuration

Features:

  • Adjustable Stop Set Screw
  • Keyphasor Probe Holder
  • Speed Control Knob
The Bently Nevada TK3-2E is a TK3 Proximity System Test Kit. The Bently Nevada TK3-2E is an electric-driven version of the test kit. The Bently Nevada TK3-2E simulates shaft vibration and position for calibrating Bently Nevada monitors. The Bently Nevada TK3-2E verifies the operating condition of monitor readouts and the condition of the proximity transducer system. A properly calibrated system using the Bently Nevada TK3-2E ensures that transducer inputs and resulting monitor readings are accurate.

The Bently Nevada TK3-2E uses a removable spindle micrometer assembly to check the transducer system and position monitor calibration. This assembly on the Bently Nevada TK3-2E features a universal probe mount that accommodates probe diameters from 5mm to 19mm (0.197in to 0.75in). The mount on the Bently Nevada TK3-2E holds the probe while the user moves the target toward or away from the probe tip in calibrated increments. The user records the output from the Proximitor Sensor using a voltmeter. The spindle micrometer assembly on the Bently Nevada TK3-2E also features a magnetic base for ease of use in the field.

The TK3-2E Bently Nevada Calibration Instrument may still be available for purchase and support from Amikon Limited beyond End-Of-Life (EOL) by the manufacturer (OEM).
Bently Nevada TK3-2E Calibration Instrument Manuals, Datasheets, Drivers, Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
The user can then compare a vibration monitor's reading to the known mechanical vibration signal input viewed by the proximity probe. The Bently Nevada TK3-2E provides a known mechanical vibration reference for verifying monitor accuracy. The Bently Nevada TK3-2E is for indoor use only. The maximum altitude for the Bently Nevada TK3-2E is 2000m.
 
The Bently Nevada TK3-2E has an operational temperature range of 0°C to 50°C (32°F to 122°F). Temporary operation below minimum temperature is acceptable for the Bently Nevada TK3-2E. For extended continuous use, the maximum operating temperature of the Bently Nevada TK3-2E is 40°C. The storage temperature range of the Bently Nevada TK3-2E is -18°C to 65°C (0°F to 150°F). The Bently Nevada TK3-2E operates in 95% non-condensing humidity. The Bently Nevada TK3-2E is rated to meet IP54 for dust and water exposure when closed.
  • Power Generation: Ensuring early fault detection on massive turbine-generator shafts
  • Oil & Gas Processing: Verifying safety trip and alarm systems on high-speed critical compressors
  • Chemical & Refining: Protecting rotating assets in hostile processing environments
  • Industrial Automation R&D: Allowing engineers to benchmark and validate new transducer installations
This content has been produced using multiple sources.Amikon takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
Voltage Selection: Prior to plugging in the unit, the 115/230 VAC selector switch on the front panel must be checked and set to match the local line voltage to avoid permanent circuit damage.
Environmental Constraints: The TK3-2E is rated exclusively for indoor use or controlled field environments, up to a maximum altitude of 2,000 meters and a maximum temperature of 40°C.Safety Clearing: The kit must be placed on a flat, stable surface. Technicians must keep all loose clothing, jewelry, and fingers clear of the exposed, rotating wobble plate.

Technical notes

Vibration monitors are calibrated using the motor-drivenwobble plate. A swing-arm assembly located over thewobble plate holds the proximity probe in place. Thisassembly uses a universal probe mount, identical to thatused with the spindle micrometer assembly. By using theabsolute scale factor of the proximity probe in conjunctionwith a multimeter, the user adjusts the probe to find aposition where the desired amount of mechanical vibration(as determined by peak-to-peak DC voltage output) ispresent. No oscilloscope is needed.

FAQs

  • What is the TK3-2E?+
    The Bently Nevada TK3-2E is an electrically powered calibration instrument used to simulate shaft vibration and position, calibrate machinery monitors, and verify the accuracy of proximity transducer systems in industrial environments
  • What is the primary purpose of the TK3-2E?+
    It provides a reference mechanical motion to perform field functional tests of machinery protection systems. It ensures your proximity probes, extension cables, and monitors work accurately as a complete system.
  • Does the unit require an external power source?+
    Yes, the TK3-2E is electrically powered and requires an input of 95–125 Vac or 190–250 Vac (50/60 Hz, 1A minimum).
  • What is the difference between the TK3-2E and the TK3-2G?+
    Both models perform the same calibration functions but utilize different power sources. The TK3-2E uses electricity, whereas the TK3-2G is pneumatically powered (using pressurized air) to ensure safety in explosive or flammable environments.
  • What are the electrical power requirements for the TK3-2E?+
    The device operates on a universal dual-voltage layout. It requires a power supply of either 95–125 Vac or 190–250 Vac, at 50/60 Hz, with a minimum current of 1A. You must set the 115/230 VAC selection switch to the correct position before plugging it in to avoid damaging the unit.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: Amikon Limited sells new and surplus products and develops channels for purchasing such products. Amikon Limited is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because Amikon Limited is not an authorized distributor of this product, the Original Manufacturer's warranty does not apply. Amikon Limited is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.
Product

You May Also Like

Product

Product Browsing History

Get a quick price fo TK3-2E
*Quantity
*E-mail
*Mobile
Company
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Amikong please read our privacy policy.