IC693MDL931

OUTPUT MODULE

Require for Quote:

Need more help? You may also find the answer in our FAQ section

Shipping Information

  • For inventory products, we support same day shipping upon payment.
  • For urgent needs, we offer same-day shipping on most items for orders placed before 2:00 PM UTC+8 Simply mention your preferred next-day shipping when place the order, and your order will be prioritized to minimize downtime.
  • For indent items, typical turnaround is 1-3 weeks, depending on parts availability and scarcity.

Technical specifications for IC693MDL931

  • Product Model
    IC693MDL931
  • Product Parameters
    OUTPUT MODULE
  • Tariff Code
    8537101190
  • Country of origin
    USA
  • Place of shipment
    Xiamen, China
  • Estimated Shipping Size
    3.5x13x13.5cm
  • Manufacturer
    General Electric
  • Weight
    0.28 kg
  • Rated Voltage
    24 volts DC, 120/240 volts AC, 50/60 Hz
  • Output Voltage Range
    5 to 30 volts DC/5 to 250 volts AC, 50/60 Hz
  • Outputs per Module
    8 isolated outputs
  • Isolation
    1500 volts between field side and logic side500 volts between groups
  • Maximum Load
    8 amps resistive maximum per output20 amps maximum per module for UL installations
  • Minimum Load
    10 mA
  • Inrush Current
    8 amps maximum for one cycle
  • On Response Time
    15 ms maximum
  • Off Response Time
    15 ms maximum
  • Output Leakage Current
    1 mA maximum at 250 volts AC
  • Internal Power Consumption
    45 mA (all outputs on) from 5 volt bus on backplane100 mA (all outputs on) from relay 24V bus on backplane

Description

IC693MDL931
OUTPUT MODULE
ISOLATED RELAY OUTPUT
8 AMP
8 POINT
N.C. AND FORM C
5-30 VDC OUTPUT
5-250 VAC OUTPUT

Revisions

Revision Part #

Also known as

IC693MDL931/D
IC693MDL931-D Rev D

Information

Overview Manuals Technical notes Product Applications Installation and Safety

Features:

  • 8 Amp Isolated Relay Output
  • Series 90-30 Programmable Logic Controller
  • Provides 4 normally-closed and 4 Form C relay circuits
The IC693MDL931 is an output module from the GE Fanuc Emerson Series 90-30, designed for use in control systems. This relay output module provides isolated relay connections and supports both AC and DC output voltage.

This 8 Amp Isolated Relay Output module for the Series 90-30 Programmable Logic Controller provides 4 normally-closed and 4 Form C relay circuits for controlling output loads provided bythe user. The output switching capacity of each circuit is 8 amps for the normally-closedcontacts or the normally open contacts. Each output relay is isolated from the other relays, andeach relay has a separate common power output terminal. The relay outputs can control a widerange of user-supplied load devices, such as: motor starters, solenoids, and indicators. The usermust supply the AC or DC power to operate the field devices connected to this module. Thereare no fuses on this module

The IC693MDL931 GE Isolated Relay Output module may still be available for purchase and support from Amikon Limited beyond End-Of-Life (EOL) by the manufacturer (OEM).
GE IC693MDL931 Isolated Relay Output module Manuals, Datasheets, Drivers, Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
LED indicators which provide the ON/OFF status of each point are located at the top of themodule. The LEDs are arranged in two horizontal rows with eight green LEDs in each row.This module uses the top row labeled A1 through 8 (points 1 through 8) for output status; thebottom row is not used and the fuse LED is not used. An insert goes between the inside andoutside surface of the hinged door. The surface towards the inside of the module (when thehinged door is closed) has circuit wiring information, and circuit identification information canbe recorded on the outside surface. The outside left edge of the insert is color-coded red toindicate a high-voltage module. This module can be installed in any I/O slot of a 5 or 10-slotbaseplate in a Series 90-30 PLC system.
 
  • Packaging & Material Handling:Monitors sensors & coordinates conveyors for high-speed packaging
  • Water & Waste Management:Monitors pump status & tank level alarms in water treatment
  • Manufacturing Processes:Handles AC signaling for injection molding, food & mining
  • Building Infrastructure:Elevator control & large-scale HVAC monitoring
This content has been produced using multiple sources.Amikon takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
Compatibility: Can be installed in any I/O slot of a Series 90-30 or RX3i 5-slot or 10-slot baseplate.
Hot Swapping: Warning: This module is not compatible with hot swap operations. Removing or inserting it while the backplane is powered can damage the module or system.
Wiring: Circuit wiring diagrams are located on the inside surface of the module's hinged door. The module door insert is color-coded red on the left edge to indicate it is a high-voltage module.
Fusing: There are no internal fuses on this module.

FAQs

  • What is IC693MDL931 ?

    +
    The GE Fanuc IC693MDL931 is an 8-point isolated relay output module from the Series 90-30 Programmable Logic Controller (PLC) family.
  • What type of outputs does the IC693MDL931 provide?

    +
    It provides 8 isolated relay outputs, comprising 4 normally-closed (NC) and 4 Form C (SPDT) relay circuits.
  • Is the IC693MDL931 hot-swappable?

    +
    No. The IC693MDL931 is not compatible with hot swap operations. Removing or inserting this module while the backplane is powered can cause damage to the module or other system components.
  • Does IC693MDL931 require an external power supply?

    +
    Yes, the user must provide an external AC or DC power supply to operate field devices connected to the relay circuit.
  • Where can this module be installed?

    +
    The IC693MDL931 can be installed in any I/O slot of a 5- or 10-slot baseplate in a Series 90-30 PLC system.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: Amikon Limited sells new and surplus products and develops channels for purchasing such products. Amikon Limited is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because Amikon Limited is not an authorized distributor of this product, the Original Manufacturer's warranty does not apply. Amikon Limited is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.
Product

You May Also Like

Product

Product Browsing History

Get a quick price fo IC693MDL931
*Quantity
*E-mail
*Mobile
Company
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Amikong please read our privacy policy.