Close Menu
Get Parts Quote
Name
Company *
WhatsApp / WeChat (For Faster Quote) *
Email *
Address
City
State / Province / Region
Zipcode
Country
Quantity *
Part Number *
Manufacturer
Preferred Condition
Additional Information
Cancel
In Stock
Fast Shipping Available
HACH DR3900 LPG440.99.00002
· Product image is representative; revision or series may vary. Contact us to request a specific version.
Ships by Friday, September 25

DR3900 LPG440.99.00002

benchtop VIS spectrophotometer

Shipping Information

  • For inventory products, we support same day shipping upon payment.
  • For urgent needs, we offer same-day shipping on most items for orders placed before 2:00 PM UTC+8 Simply mention your preferred next-day shipping when place the order, and your order will be prioritized to minimize downtime.
  • For indent items, typical turnaround is 1-3 weeks, depending on parts availability and scarcity.
Customs & Documentation

Customs & Documentation

HS classification and country of origin are stated as commercial references and confirmed on the written quotation and shipping documents.

Payment

Payment

Payment is accepted by bank transfer (T/T) in the currencies confirmed in the written quotation.

Product Condition

Product Condition

Product identity, label, visible condition and packing are checked against the written order before dispatch.

Quantity
Mobile *
Country/Region *
E-mail *
Company
Content *
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Amikong please read our privacy policy.
  • 20+

    years in automation
  • ISO 9001

    certified quality system
  • 12 months

    amikon warranty
  • 2-hour reply

    from your account manager
  • Success Story

    solutions in action
PRODUCT DESCRIPTION

DR3900 LPG440.99.00002 benchtop VIS spectrophotometer

HACH DR3900 LPG440.99.00002 benchtop VIS spectrophotometer supports Hach DR3900 laboratory photometry systems. The assembly combines the documented electrical, signal and mechanical interfaces for its assigned system position. It processes or transfers the defined operating signals through the configured equipment path. The resulting interface supports repeatable control, protection or measurement performance within the approved installation.
ACTUAL APPLICATIONS

Verified application context for DR3900 LPG440.99.00002

Manufacturer documentation supports these equipment applications when the complete system configuration and interfaces are verified.
  • 01 · WATER & WASTEWATER

    Treatment laboratory water quality testing

    Laboratory analysis systemsDisinfection residual sample testingNutrient test vial measurement
  • 02 · FOOD & BEVERAGE

    Production laboratory ingredient verification

    Quality control systemsBeverage color absorbance testingIngredient concentration sample checks
  • 03 · CHEMICAL PROCESSING

    Batch laboratory formulation analysis

    Process laboratory systemsBatch solution concentration testingProcess sample absorbance measurement

Technical specifications for DR3900 LPG440.99.00002

  • Product Model
    DR3900 LPG440.99.00002
  • Product Parameters
    benchtop VIS spectrophotometer
  • In stock
    1 unit
  • Manufacturer
    HACH
  • Wavelength Range
    320 to 1100 nm
  • Wavelength Accuracy
    ±1.5 nm from 340 to 900 nm
  • Wavelength Repeatability
    ±0.1 nm
  • Wavelength Resolution
    1 nm
  • Spectral Bandwidth
    5 nm
  • Photometric Range
    ±3.0 absorbance units
  • Photometric Accuracy
    5 mAbs to 0.5 Abs
  • Display Resolution
    800 × 480 pixels
  • Display Type
    7-inch TFT color touchscreen
  • Result Storage
    2000 measurement records
  • Program Capacity
    More than 220 methods
  • User Programs
    100 methods
  • Operating Temperature
    10 to 40 °C
  • Enclosure Rating
    IP30
  • Power Supply
    110 to 240 V, 50/60 Hz
View all additional

Alternative Names

DR3900 LPG440.99.00002 HACH benchtop VIS spectrophotometer Hach DR3900 laboratory photometry systems benchtop VIS spectrophotometer
SYSTEM & REPLACEMENT CHECK

Information needed before ordering

Three direct checks to secure your system integration and minimize ordering risks.

Information

System integration Replacement check Manuals & support
SYSTEM INTEGRATION

Match DR3900 LPG440.99.00002 to the installed Hach DR3900 laboratory photometry systems

HACH DR3900 LPG440.99.00002 is a benchtop VIS spectrophotometer for the Hach DR3900 laboratory photometry systems. Its exact article suffix determines the supported interface, signal or communication function and the approved companion equipment.
Engineering should compare wavelength resolution (1 nm), spectral bandwidth (5 nm) and photometric range (±3.0 absorbance units) with the installed system design. Confirm connector keying, addressing and configuration-tool support before connection.
Use the manufacturer documentation for the complete wiring and configuration sequence. Validate communication, signal conversion or control response with the connected equipment, then archive measured results and the final configuration with the asset record.

Features:

  • Exact identity: DR3900 LPG440.99.00002
  • Product class: benchtop VIS spectrophotometer
  • Family: Hach DR3900 laboratory photometry systems
The HACH DR3900 LPG440.99.00002 requires documented system integration before energising the equipment.
REPLACEMENT CONTROL

Verify the complete DR3900 LPG440.99.00002 identity before exchange

Replace DR3900 LPG440.99.00002 only after matching the complete article code, benchtop VIS spectrophotometer, installed Hach DR3900 laboratory photometry systems role and documented hardware or firmware revision. Similar housings and related family numbers do not establish functional interchangeability.
Photograph the nameplate, keyed connectors, terminal numbering, cable routing, shields, earth points and adjacent modules. Export the applicable controller, HMI, drive or network configuration and record addresses, parameters and diagnostic messages before removal.
After fitting the verified article, restore the controlled configuration and check every affected signal or communication path. Review status indications and diagnostic buffers, run the documented functional test at a safe operating point and retain the final acceptance record.

Features:

  • Exact identity: DR3900 LPG440.99.00002
  • Product class: benchtop VIS spectrophotometer
  • Family check: Hach DR3900 laboratory photometry systems
The HACH DR3900 LPG440.99.00002 requires documented replacement verification before energising the equipment.
DOCUMENTATION STATUS

Browse the Manuals, Datasheets, Official Documents, Links

Important Notice: Official documents are provided through manufacturer links. Accessories, manuals, cables, calibration data, software and certificates are included only when listed in the quotation.

Features:

  • Official CA-H200C product references are checked before order
  • Confirm camera and controller compatibility in current manuals
  • Accessories are supplied only when listed in the quotation
Documentation for the KEYENCE CA-H200C cable must be matched to the connected camera and controller; confirm manual availability in the written quotation.

Also searched as

Important notice

Manuals, software, firmware, cables, calibration data and accessories are included only when listed in the quotation. AMIKON is an independent supplier and is not affiliated with or authorised by the manufacturer.
This content has been produced using multiple sources. Takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
BUYER INFORMATION

Commercial terms without hidden steps

Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • 01

    Shipping & delivery

    Dispatch
    Eligible stock: same / next day
    Carriers
    DHL, FedEx or UPS
    Ship from
    Xiamen, China
    Packed size
    15.1 × 35.0 × 25.5 cm
    Shipping weight
    4.20 kg
  • 02

    Payment & customs

    Payment
    Bank transfer (T/T)
    Currencies
    USD · EUR · GBP · RMB
    Credit cards
    Not accepted
    HS reference
    85371098
    Origin
    United States
  • 03

    Warranty & returns

    Warranty
    12 months from AMIKON
    Inspection
    Label, condition and packing checks
    Returns
    Prior RMA authorisation required
    Compatibility
    Confirm before order
    OEM warranty
    Does not apply
Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • Part checked

    Full suffix recorded
  • Condition checked

    Label and appearance
  • Packing checked

    Antistatic protection
  • Tracking supplied

    Established couriers
  • Sandy Lin

    Dedicated account manager · 15+ years
FREQUENTLY ASKED QUESTIONS

Questions buyers ask about DR3900 LPG440.99.00002

Direct answers about identity, compatibility, stock, warranty, payment and shipping.
  • Which identifier should be quoted for DR3900 LPG440.99.00002?

    Use the complete DR3900 LPG440.99.00002 identifier, benchtop VIS spectrophotometer, quantity and clear nameplate photographs.
  • What should be matched before installing DR3900 LPG440.99.00002?

    Match the documented ratings, connections, revision and assigned role in Hach DR3900 laboratory photometry systems.
  • What should incoming inspection cover for DR3900 LPG440.99.00002?

    Inspect the label, housing, connectors, terminals and transport condition before use.
  • Can a related Hach DR3900 laboratory photometry systems article replace DR3900 LPG440.99.00002?

    Do not assume interchangeability; compare the full identity, ratings, interfaces and configured role.
  • Which records should be captured before removing DR3900 LPG440.99.00002?

    Record connector positions, wire labels, cabinet location, adjacent hardware and current diagnostics.
  • Which configuration should be retained for DR3900 LPG440.99.00002?

    Archive the applicable controller or monitoring configuration, addresses and diagnostic records.
  • How should DR3900 LPG440.99.00002 be commissioned after installation?

    Restore verified wiring and configuration, then test the affected benchtop VIS spectrophotometer function under controlled conditions.
  • Which documents should remain with the DR3900 LPG440.99.00002 asset record?

    Retain receiving inspection, nameplate images, connection records, test results and final acceptance evidence.
READY TO VERIFY YOUR PART?

Get a DR3900 LPG440.99.00002 quote with price, lead time and revision check.

Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: Amikon Limited sells new and surplus products and develops channels for purchasing such products. Amikon Limited is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because Amikon Limited is not an authorized distributor of this product, the Original Manufacturer's warranty does not apply. Amikon Limited is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.
Product

Product Browsing History