Close Menu
Get Parts Quote
Name
Company *
Phone *
Email *
Address
City
State / Province / Region
Zipcode
Country
Quantity *
Part Number *
Manufacturer
Preferred Condition
Additional Information
Cancel
HIMA HIMATRIX F30 01
HIMA HIMATRIX F30 01
HIMA HIMATRIX F30 01
· Product image is representative; revision or series may vary. Contact us to request a specific version.

HIMATRIX F30 01

Controller

Require for Quote:

Need more help? You may also find the answer in our FAQ section

Shipping Information

  • For inventory products, we support same day shipping upon payment.
  • For urgent needs, we offer same-day shipping on most items for orders placed before 2:00 PM UTC+8 Simply mention your preferred next-day shipping when place the order, and your order will be prioritized to minimize downtime.
  • For indent items, typical turnaround is 1-3 weeks, depending on parts availability and scarcity.

Technical specifications for HIMATRIX F30 01

  • Product Model
    HIMATRIX F30 01
  • Spare Model
    F30 01
  • Product Parameters
    Controller
  • Tariff Code
    8537101190
  • Country of origin
    USA
  • Place of shipment
    Xiamen, China
  • Estimated Shipping Size
    25.5x6.5x11.3cm
  • Manufacturer
    HIMA
  • Weight
    1.05 kg
  • Ethernet interfaces
    4 x RJ-45, 10BASE-T/100BASE-Tx with integratedswitch
  • Fuse (external)
    10 A time-lag (T)
  • Buffer for date/time
    Gold capacitor
  • Operating temperature
    0...+60 °C
  • Storage temperature
    -40...+85 °C

Description

F3001
SAFETY MODULE
PLC DCS MODULE

Information

Overview Manuals Technical notes Need more info

Features:

  • 20 digital inputs, 8 digital outputs
  • Protection class III in accordance with IEC/EN 61131-2
  • for ELOP II Factory programming tool
The HIMA HIMatrix F30 01 is a Controller (20 digital inputs, 8 digital outputs),Operating temperature: 0...+60 °C,for ELOP II Factory programming tool , safety-related controller used in industrial automation for applications requiring high safety standards (SIL 3).

The HIMatrix F30 01 HIMA Safety-Related Controller may still be available for purchase and support from Amikon Limited beyond End-Of-Life (EOL) by the manufacturer (OEM).
HIMA HIMatrix F30 01 Safety-Related Controller Manuals, Datasheets, Drivers, Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
The controller pulses the digital outputs to detect the line short-circuits and open-circuits to the digital inputs. To do so, configure the Value.[BOOL] -> system variable in SILworX and the DO[0x].Value system signal in ELOP II Factory. The variables for the pulsed outputs
must begin with channel 1 and reside in direct sequence, one after the other.
If the following faults occur, the FAULT LED located on the front plate of the controller blinks, the inputs are set to low level and an (evaluable) error code is created:
1.Cross-circuit between two parallel lines,
2.Improper connections of two lines (e.g., DO 2 to DI 3),
3.Earth fault of a line (with earthed ground only),
4.Open-circuit or open contacts, i.e., also if one of the two EMERGENCY STOP switches
previously mentioned the FAULT LED is being engaged.
We know that questions occur, and sometimes you need more details or a closer look to make the right decision. That’s why we make it easy for you to reach out directly—so you’re never left wondering.
 
With our team, you're just a message away from clarity and confidence. Whether you have a specific question, need a particular image, video or more details, the request click puts you in control. Let us know what you need, and we’ll bring the answers straight to you—no guesswork required!

FAQs

  • What is the HIMatrix F30 01 ?+
    The HIMA HIMatrix F30 is a compact, safety-related controller designed for industrial automation, offering high safety certifications (SIL 3 / PL e)
  • What is the HIMatrix F30?+
    It is a compact, safety-related controller in a metal housing with 20 digital inputs and 8 digital outputs.
  • What are HIMatrix F30 01 safety certifications?+
    It is certified up to SIL 3 (IEC 61508) and Performance Level e (EN ISO 13849-1).
  • What HIMatrix F30 01 environmental conditions can it handle?+
    The standard operating temperature is 0...+60 °C, with a storage temperature of -40...+85 °C. Special models for the rail industry can handle -25°C to 70°C.
  • What HIMatrix F30 01 communication protocols are supported?+
    It supports SafetyEthernet, PROFIBUS-DP, OPC, MODBUS RTU/TCP (Master & Slave), and EtherNet/IP.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: Amikon Limited sells new and surplus products and develops channels for purchasing such products. Amikon Limited is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because Amikon Limited is not an authorized distributor of this product, the Original Manufacturer's warranty does not apply. Amikon Limited is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.
Product

You May Also Like

Product

Product Browsing History

Get a quick price fo HIMATRIX F30 01
*Quantity
*E-mail
*Mobile
Company
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Amikong please read our privacy policy.