Enhanced Logic Manager Module
Input Voltage:Typically 24 VDC
Power Consumption:Around 25 W
Operating Temperature Range:Typically -20°C to 60°C
Storage Temperature Range:-40°C to 85°C.
Relative Humidity:5% to 95% non-condensing.
IKB Keyboard
Model Number: 51196694-350/U1
AID-3 9395-00379-034/B
Key Layout: 101 keys, including a numeric keypad.
Cable Length: 3 meters.
Compatibility: Designed for use with
Honeywell industrial control systems
Analog Output Module
Output Type:4-20 mA
Output Channels:16
Output Temperature Drift:0.005% of Full Scale/°C
Output Readback Accuracy:±4% of Full Scale
Resolution:± 0.05% of Full Scale
Directly Settable Output Current Range:0 mA, 2.9 mA to 21.1 mA
Maximum Resistive Load:800 ohms
Maximum Open Circuit Voltage:22 V
Industrial Current Sensors
Current Rating:300 A
Sensor Type:Closed Loop
Brand:Honeywell
Maximum Operating Temperature: + 85 C
Minimum Operating Temperature: - 40 C
Product Type: Industrial Current Sensors
Subcategory: Sensors
I/O Communication
Modbus RTU/ASCII or Modbus TCP
Ethernet/IP
Profibus or Profinet
RS-232/RS-485 serial communication
ACCELEROMETER
Acceleration Range: ±2g, ±5g, ±10g, or ±50g
Voltage output, typically 0-5V or 0-10V
Supply Voltage: 5V DC or 12V DC
Operating Temperature: -40°C to +85°C
Analog Input Module
Universal Input Output IOTA
Input Channels 1 16 Channels
Common Mode Voltage, dc to 60 Hz -6 to +5 V peak
A/D Converter Resolution 16 bits
Normal Mode Rejection Ratio, at 60 Hz 19 dB
Normal Mode Filter Response Single-pole RC, -3 dB @ 6.5 Hz
Input Impedance (voltage inputs) > 10 M Ω powered
Input Scan Rate 50 ms
High-Speed Network Communication Modules
Supports fiber-optic medium
NFPA Class B or Class A operation
Data is immune to all environmental noise
Optical isolation prevents ground loops
High-Speed NFN fiber-optic medium
Fiber type: 62.5/125 micrometers (multi-mode);
50/125 micrometers (multimode),
or 9/125 micrometers (single mode)
Maximum attenuation: 10 dB with 62.5/125 μm cable, 6
SMART PRESSURE TRANSMITTER
ST3000
Accuracy = +/-0.0375%
Stability = +/-0.01% per year
Reliability = 470 years MTBF
Rangeability = 400 to 1
Pulse Input Processor
CE-compliant, not conformally coated
Redundancy not supported
Input Channels: 8
Input Scan Rate: 32 samples per second
Available Input Types:
Rectangular
Sine Wave
EHPM02 Module
Type: EHPM02
Series: Experion PKS system
Voltage Requirements:24 V DC
Operating Temperature: -40°C to 70°C
Storage Temperature: -40°C to 85°C
Relative Humidity: 5% to 95% (non-condensing)
Analog Input Module
51309136125
PLC MODULE
SIZE A
HIGH LEVEL ANALOG INPUT
16 INPUTS
SCREW TERMINALS
Digital Input Module
Input Channels 32
Galvanic Isolation 1500 VAC RMS or ±1500 VDC
Isolation Technique Optical (in IOM)
DI Power Voltage Range 18 to 30 VDC
ON Sense Voltage/Current 13 VDC (min) or 3 mA (min)
OFF Sense Voltage/Current 5 VDC (max) or 1.2 mA (max)
Input Impedance 4.2
Absolute Delay Across Input Filter and Isolation 5 ms ± 20%
Field Resistance for Guaranteed ON Condition 300 max @ 15 VDC
Analog Input Module
Output Type 4-20 mA
Output Channels 16
Output Ripple < 100 mV peak-to-peak at
power line frequency, across 250 load
Output Temperature Drift 0.005% of Full Scale/°C
Output Readback Accuracy ±4% of Full Scale
Output Current Linearity ± 0.05% of Full Scale nominal
Resolution ± 0.05% of Full Scale
Calibrated Accuracy ± 0.35% of Full Scale (25oC) including linearity
Directly Settable Output Current Range 0 mA, 2.9 mA to 21.1 mA
Maximum Output Compliant Voltage 16 V
Analog Input Module
Common Mode Rejection Ratio, dc to 60 Hz 70 dB
Common Mode Voltage, dc to 60 Hz -6 to +5 V peak
A/D Converter Resolution 16 bits
Normal Mode Rejection Ratio, at 60 Hz 19 dB
Normal Mode Filter Response Single-pole RC, -3 dB @ 6.5 Hz
Maximum Normal Mode Input ± 30 Volts
Crosstalk, dc to 60 Hz -60 dB
Input Impedance (voltage inputs) > 10 M Ω powered
Input Scan Rate 50 ms
Analog Input Module
Input Type: Voltage current
(2-wire or self-powered transmitters)
Input Channels : 16 Channels
Common Mode Voltage, dc to 60 Hz -6 to +5 V peak
A/D Converter Resolution 16 bits
Normal Mode Rejection Ratio, at 60 Hz 19 dB.
Normal Mode Filter Response Single-pole RC, -3 dB @ 6.5 Hz
Maximum Normal Mode Inpu ± 30 Volts
Crosstalk, dc to 60 Hz -60 dB
Input Impedance (voltage inputs) > 10 M Ω powered
Input Scan Rate 50 ms
System Display
System Security via Password
Color Touch Screen with Full Screen Color Graphics
4 LEDs: Power / Network / COM 2 / COM 1
Modbus Master/Slave Configurations
Key Process Variable Display Capability
3 Display Operational Modes:
Local, Switchable or System
Touch Panel
Screen Size 15.0 ”
Resolution 1024 x 768
Color 256
Brightnes 250 cd / m
Touch Type Analog
Touch Cell 1024 x 768
CPU 32 bit RISC
Memory 12M Flash Memory
Operating Power AC 85 – 264 V
Power Consumption Max. 25 W
Operating Temperature 0 – 50 °C
Storage Temperature -10 – 60 °C
ASSY HPM I/O LINK CC
Input Voltage: 5 VDC
Operating Temperature: 0°C to +60°C.
Storage Temperature: -40°C to +85°C.
Humidity: 5% to 95% non-condensing.
Interference Resistance: Complies with industrial EMC
TPS (TotalPlant Solution)
Experion PKS
TDC 3000
SC S300 SAFETY CONTROLLER
Safety Standard Compliance
IEC 61508 SIL3, ISO 13849-1
Operating Voltage 24 VDC
Power Consumption <15 W
Operating Temperature -10°C to +60°C
Storage Temperature -40°C to +85°C
Mounting Options DIN rail or panel mount
SC S300 SAFETY CONTROLLER
Safety Standard Compliance
IEC 61508 SIL3, ISO 13849-1
Operating Voltage 24 VDC
Power Consumption <15 W
Operating Temperature -10°C to +60°C
Storage Temperature -40°C to +85°C
Mounting Options DIN rail or panel mount
SM RIO 36 inch Carrier
Product Type : SM RIO 36 inch Carrier
Operating temperature : -40 .. +70 degC
Storage temperature : -40 .. +85 degC
Relative humidity : 10..95% (non condensing)
Pollution : Pollution degree 2 or better
Approvals : CE; UL pending

Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.