Amikon Limited comprehensive Honeywell automation solutions, specializing in the supply of the following core product lines:
Experion PKS ,TDC 3000, TDC 2000, Distributed Control Systems,Experion LS,Safety Manager™ Safety Instrumented Systems,FSC™ (Fail Safe Controller) Safety Systems Additionally,we specialize in providing critical Obsolete Parts for discontinued Honeywell equipment across all legacy systems.
Whether you require components for specific platforms (such as Experion PKS or TDC 3000), or need to source replacement or obsolete parts based on equipment functionality, please Email now: info@amikon.cn+86-18020776786.
We are committed to sourcing the Honeywell process control products you need.
Amikon Limited comprehensive Honeywell automation solutions, specializing in the supply of the following core product lines:
Experion PKS ,TDC 3000, TDC 2000, Distributed Control Systems,Experion LS,Safety Manager™ Safety Instrumented Systems,FSC™ (Fail Safe Controller) Safety Systems Additionally,we specialize in providing critical Obsolete Parts for discontinued Honeywell equipment across all legacy systems.
Whether you require components for specific platforms (such as Experion PKS or TDC 3000), or need to source replacement or obsolete parts based on equipment functionality, please Email now: info@amikon.cn+86-18020776786.
We are committed to sourcing the Honeywell process control products you need.
Event Input
SOE, 32 channels
32‑pt event input module
Input point:32 point
Memory size:Records 1Mbit event information
Rated input voltage:DC24V
Rated input current About:4mA
On voltage/On current:DC19V or above / 3 mA or above
Off voltage/ Off current:DC11V or less / 1.7 mA or less
Input resistance About:5.6 kΩ
RESISTANCE TEMPERATURE DETECTOR
8-CHANNEL INPUT
TWO TYPES OF RTD SENSORS: PT100/JPT100
5 VOLT CURRENT CONSUMPTION
18-POINT TERMINAL BLOCK
LED INDICATORS
HART Input, 8 channels
RESISTANCE TEMPERATURE DETECTOR
4-CHANNEL INPUT
TWO TYPES OF RTD SENSORS: PT100/JPT100
5 VOLT CURRENT CONSUMPTION
18-POINT TERMINAL BLOCK
LED INDICATORS
HART Input, 4channels
64 point Transistor Output Module
Output point:64 point
Isolation method:Relay isolation
Rated load voltage/current:DC 12 / 24V
Load voltage range:DC 10.2 ~ 26.4V
Max. load current:0.1A / 1 point, 2A / 1COM
Off leakage current:0.1mA or less
Max. inrush current:0.7A / 10 ms or less
Max. voltage drop (On):DC 0.2V or less
Surge absorber:Zener diode
32 point Transistor Output Module
Output point:32 point
Isolation method:Relay isolation
Rated load voltage/current:DC 12 / 24V
Load voltage range:DC 10.2 ~ 26.4V
Max. load current:0.1A / 1 point, 2A / 1COM
Off leakage current:0.1mA or less
Max. inrush current:0.7A / 10 ms or less
Max. voltage drop (On):DC 0.2V or less
Surge absorber:Zener diode