Triconex 8110 High Density Main Chassis
Invensys 8110
Invensys 8110
Triconex 8110 High Density Main Chassis
Invensys 8110
Invensys 8110
· Product image is representative; revision or series may vary. Contact us to request a specific version.
Ships by Wednesday, September 16

8110

Main controller chassis

Shipping Information

  • For inventory products, we support same day shipping upon payment.
  • For urgent needs, we offer same-day shipping on most items for orders placed before 2:00 PM UTC+8 Simply mention your preferred next-day shipping when place the order, and your order will be prioritized to minimize downtime.
  • For indent items, typical turnaround is 1-3 weeks, depending on parts availability and scarcity.
Customs & Documentation
We prepare clear, order-specific documentation for every international shipment, including the commercial invoice, packing list and available product or compliance documents. Before dispatch, our logistics team confirms the consignee details, declared value, shipping terms and destination requirements with you. Tracking information is provided after shipment, helping your team prepare for import clearance with confidence.
Documents checked before dispatch · Shipment details confirmed · Global tracking provided
Payment
Payment is by bank wire only in RMB/CNY, GBP, EUR or USD. Amikon does not accept credit cards or provide credit terms. Cleared payment is required before shipment unless the written quotation expressly states otherwise.
Product Condition
Factory New These are new and current items that are procured directly from the manufacturer.
New In Sealed Package Parts are new. They have not been used and still have their original package seal intact.
New in Original Package These parts are new. The packages were not originally sealed by their original manufacturer.
Quantity
Mobile *
Country/Region *
E-mail *
Company
Content *
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Amikong please read our privacy policy.
  • 20+

    years in automation
  • ISO 9001

    certified quality system
  • 12 months

    amikon warranty
  • 2-hour reply

    from your account manager
  • Success Story

    solutions in action
PRODUCT DESCRIPTION

8110 Main controller chassis for the Tricon safety instrumented system

Triconex 8110 is a Main controller chassis used with the Tricon safety instrumented system. The complete order reference identifies the required hardware and must be matched to the installed chassis, baseplate, cable or field termination.

Manufacturer documentation lists the applicable electrical, signal and installation characteristics. Verify the nameplate, hardware revision, connector layout and project records before replacement.
ACTUAL APPLICATIONS

8110 supports Triconex safety-system lifecycle work

Use this Main controller chassis only after matching its documented hardware, field circuits and installed controller configuration.
  • 01 · SAFETY CONTROL

    Maintain configured shutdown functions

    Preserve the approved logic path, point assignment and voting architecture during scheduled maintenance.
  • 02 · FIELD INTEGRATION

    Connect the documented signals

    Confirm voltage, current, channel, termination and protective-earth requirements before wiring the 8110.
  • 03 · LIFECYCLE SERVICE

    Verify replacement operation

    Run diagnostics and a site functional test before returning the affected safety function to service.

Technical specifications for 8110

  • Product Model
    8110
  • Product Parameters
    Main controller chassis
  • Place of shipment
    Xiamen, China
  • In stock
    1 unit
  • Manufacturer
    Invensys
  • Product Class
    Main controller chassis
  • System Platform
    Tricon fault-tolerant controller
  • Mechanical Format
    19-inch industrial rack assembly
  • Chassis Fabrication
    Black zinc-plated welded steel
  • Overall Width
    48.3 cm cabinet span
  • Overall Height
    57.8 cm installed frame
  • Overall Depth
    45.1 cm enclosure clearance
  • I/O Bus Architecture
    Three isolated RS-485 channels
  • I/O Bus Rate
    375 kbit/s triplicated transfer
  • Communication Bus Rate
    2 Mbit/s module link
  • Expansion Ports
    Six backplane bus connectors
  • Controller Keyswitch
    RUN-PROGRAM-STOP-REMOTE selection
  • Module Retention
    Mechanically keyed slot guides
  • Engineering Software
    TriStation 1131 configuration
  • Safety Architecture
    Triple modular redundant operation
View all additional

Alternative Names

8110 Triconex 8110 Invensys 8110
SYSTEM & REPLACEMENT CHECK

Information needed before ordering

Three direct checks to secure your system integration and minimize ordering risks.

Information

System integration Replacement check Manuals & support
SYSTEM CONFIGURATION

Match 8110 to the installed Triconex configuration

Triconex 8110 is a Main controller chassis for the Tricon safety instrumented system. Verify the complete product identity and controller generation before integration.
Match all mating modules, baseplates, termination panels, cables, field power and signal assignments. Preserve approved project records.
Complete the manufacturer-recommended diagnostics and site functional test after installation.

Features:

  • Exact product identity: 8110
  • Product class: Main controller chassis
  • Model-specific values listed in the specifications
The Triconex 8110 requires its ratings, wiring and installed configuration to be checked before system integration and commissioning.
INTERCHANGEABILITY

Verify the full replacement identity before commissioning

Replace Triconex 8110 only after matching the complete order reference, hardware revision, connector or terminal arrangement and installed function.
Record the existing slot, cable and field-terminal labels before removal. Transfer only configuration data approved for the exact hardware and project.
After installation, verify power, communications, every connected point, alarm response and the complete safety function.

Features:

  • Match the complete 8110 identifier
  • Compare revision, connectors and mating hardware
  • Test diagnostics and field operation before service
The Triconex 8110 requires replacement verification against the installed hardware and project documentation.
DOCUMENTATION STATUS

Browse the Manuals, Datasheets, Official Documents, Links

Important Notice: Available documents must be matched to the complete 8110 identity, installed system and applicable revision.

Features:

  • Model-specific data sheet prepared for 8110
  • Manufacturer guide reference identified before order
  • Installation steps follow Triconex maintenance controls
Documentation for Triconex 8110 must match the installed system and revision; confirm manual availability in the written quotation.

Important notice

Manuals, software, firmware, cables, calibration data and accessories are included only when listed in the quotation. AMIKON is an independent supplier and is not affiliated with or authorised by the manufacturer.
This content has been produced using multiple sources. Takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
BUYER INFORMATION

Commercial terms without hidden steps

Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • 01

    Shipping & delivery

    Dispatch
    Eligible stock: same / next day
    Carriers
    DHL, FedEx or UPS
    Ship from
    Xiamen, China
    Packed size
    58 × 48 × 44.5 cm
    Shipping weight
    24.7 kg
  • 02

    Payment & customs

    Payment
    Bank transfer (T/T)
    Currencies
    USD · EUR · GBP · RMB
    Credit cards
    Not accepted
    HS reference
    8538900000
    Origin
    United States
  • 03

    Warranty & returns

    Warranty
    12 months from AMIKON
    Inspection
    Label, condition and packing checks
    Returns
    Prior RMA authorisation required
    Compatibility
    Confirm before order
    OEM warranty
    Does not apply
Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • Part checked

    Full suffix recorded
  • Condition checked

    Label and appearance
  • Packing checked

    Antistatic protection
  • Tracking supplied

    Established couriers
  • Sandy Lin

    Dedicated account manager · 15+ years
FREQUENTLY ASKED QUESTIONS

Questions buyers ask about 8110

Direct answers about identity, compatibility, stock, warranty, payment and shipping.
  • Why must the first chassis in a Tricon system be model 8110?

    For the Main controller chassis, product class is Main controller chassis. Confirm this identity against the installed nameplate and cabinet records.
  • Where are the main processors installed within the 8110 backplane?

    For the Main controller chassis, mechanical format is 19-inch industrial rack assembly. Use the manufacturer value when checking the existing hardware and field circuit.
  • How do the six expansion ports provide two triplicated bus paths?

    For the Main controller chassis, overall width is 48.3 cm cabinet span. Record the actual installation before any connector, module or terminal is moved.
  • What enclosure dimensions and support capacity are required?

    For the Main controller chassis, i/o bus architecture is Three isolated RS-485 channels. Keep the documented arrangement intact and correct any discrepancy before energising.
  • Which keyswitch position permits TriStation program changes?

    For the Main controller chassis, expansion ports is Six backplane bus connectors. Review the indicated condition together with active controller diagnostics.
  • How are communication modules linked to the main processors?

    For the Main controller chassis, module retention is Mechanically keyed slot guides. Do not assume interchangeability from appearance; the complete configuration must agree.
  • What module keying and slot records should be checked during a chassis swap?

    For the Main controller chassis, engineering software is TriStation 1131 configuration. Retain the result in the maintenance record for the affected safety function.
  • Which controller-wide tests are required before the 8110 returns to RUN?

    For the Main controller chassis, safety architecture is Triple modular redundant operation. Complete the stated commissioning check before returning the equipment to service.
READY TO VERIFY YOUR PART?

Get a 8110 quote with price, lead time and revision check.

Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: Amikon Limited sells new and surplus products and develops channels for purchasing such products. Amikon Limited is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because Amikon Limited is not an authorized distributor of this product, the Original Manufacturer's warranty does not apply. Amikon Limited is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.
Product

Product Browsing History