MEDL UV Lamp
SIEMENS MEDL UV LAMP
WITH HEATER
Voltage (Lamp): 100–240 V AC
Power Consumption: 800 W
UV Lamp: 500–600 W
Integrated Heater: ≤200 W
UV Intensity: ≥15,000–30,000 µW/cm²
SAMPLE CELL
AMPLE CELL WITHOUT HOUSING
AND PIPING FOR CALOMAT 6
Ambient Conditions: -40°C to +85°C
Signal type:4–20 mA / 0–10 V
GATE CLAMP BOARD
GCB, GATE CLAMP BOARD
ELECTRONIC MODULE FOR CONVERTER
Voltage Range:2–5 V logic
Auxiliary Power Supply: 24 VDC
Isolation Rating: 4–5 kV AC
Snubber Capacitance: 0.47–2.0 μF
Centrifugal Fan
6SR0900-0GA05-0AD0
RH56 BLOWER LDZ10501601 BLOWER
Centrifugal Fan 230/400V 1.15/1.9KW
Siemens Inverter Fan
Centrifugal Cooling Fan
PERFECT HARMONY power cell
230V AC 740W R4D450-AK01-01
Precision Air Conditioner
Inverter Centrifugal Cooling Fan
Inverter Drive Board
frequency converter driver board
Control Circuit: 24 VDC (±10%)
DC Link Interface:510V–820V
Power Output:up to 100–1,800 A
PWM Output for IGBT gating
Control Unit
SINAMICS Control Unit
FS: H Supply: 24V DC 6.5A
Supply Voltage: 24 V DC
Current Consumption: 6.5 A
PROFIBUS DP: RS-485
Bandwidth: ≤100 Mbps
Pulse Frequency: Up to 100 µs
Inverter Power Unit
SINAMICS PERFECT HARMONY
GH180 Power cell 500A, 750V
Output Rating: 500 A at 750 V DC
Surge Capacity: ≥150%
Efficiency: ≥98.5%
DC Link Voltage: 750 V DC ±10%
Liquid Flow Rate (Coolant): 8–10 L/min
Pressure Drop: ≤2 bar at nominal flow
Inverter Power Unit
Perfect Harmony Medium voltage drive
PERFECT HARMONY power cell G4 Cell 200A, 750 V
Current: 200 A
Voltage (DC Link): 750 V DC
Power: 150 kW
Frequency: Up to 3 kHz
Dead-Time Compensation: <1 μs IGBT offset
Auxiliary Power Input:24 V DC
Inverter Power Unit
Perfect Harmony Medium voltage drive
PERFECT HARMONY power cell G4 Cell 200A, 750 V.
Current: 200 A
Voltage (DC Link): 750 V DC
Power: 150 kW
Frequency: Up to 3 kHz
Dead-Time Compensation: <1 μs IGBT offset
Auxiliary Power Input:24 V DC
Robicon G4 Power CELL
Robicon G4 Power CELL, 140A, 750V
Perfect Harmony Medium voltage drive
LDZ10500424.140
Voltage (DC Link): 750 V DC ±10%
Rated Current (Continuous): 140 A
Power Rating: 105 kW
Operating Temp.: Max cell temperature ≤85°C
Capacitors: 12,000 µF ±20% 900 V DC
FREQUENCY DRIVE POWER BOARD
Range: 320–1244 VDC
Current: 0.2–0.7 A
DC Input: 24 VDC
Output Power: 180 W
Efficiency: Likely ≥85%
Operating Ambient: 0°C to +50°C
Isolation: Input-to-output ≥2500–3000 VAC
Voltage Matching: 24 VDC
GEN5 VFD Power Cell
GEN5 VFD Power Cell
GH180 Medium Voltage Drives
Voltage Class:3.3 kV
DC Link Voltage: Standard 750 V DC
L-L Nominal:3.3 kV–6.9 kV
Continuous Output Current: 240–300 A
Pressure Transmitter
SITRANS P320 Pressure transmitter
7Mf0300-1Qf01-5Sf2-z
Pressure Range: Adjustable span
Accuracy: ±0.075% to ±0.25%
Response Time: ≤30 ms
Output Signal: 4–20 mA HART
Supply Voltage: 10.5–45 V DC
Perfect Harmony Medium voltage drive
Voltage Class: Medium Voltage
Series: Perfect Harmony GH/VFD 180
Power Range: Up to 50–100 MW
Input Voltage 50/60 Hz, 3-phase
Output Voltage:0–60 Hz variable
Output Current (max):150–3500 A
Control panel
SINAMICS PERFECT HARMONY GH180 Drives CCB
Communication Interfaces:Fiber-optic loops
Input/Output:24-bit I/O
Power Supply:24 V DC (±20%)
Ambient Temp.:0°C – +50°C
Power unit fuses
DC link/integrated power module
Input rectifiers
Output IGBTs in drives
Voltage Rating:690–1000 VDC
Current Rating (Cont.):450–700 A
Interrupting Capacity:≥100–150 kA
CELL WITH SUBMODULE
Series: Innomotics G5 Drive
Function: Power Submodule for MV Drive Systems
Current Rating (Cont.):45 A
Voltage Rating:750 V DC
Overload Capacity:Up to 150% current for 60 s
Switching Frequency:Optimized ≤20 kHz
Topology:IGBT Half-Bridge Module
Air Filter Assembly
Airflow Capacity:≥15–40 m³/h
Filter Class:G4/F9 grade
Temp. Rating:−20°C to +70°C.
Pressure Drop:10–20 Pa
Material Standards UL94-V0
Housing Material:Galvanized steel or high-density plastic
Robicon MV Drive
Input Voltage:3-phase AC 6.6 kV
Output Frequency Range:0.0–120 Hz
Rated Power:5–40 MW
Output Voltage (Motor):3 kV to 6.6 kV
Overload Capacity:120% of rated current
Efficiency:>97%
Operating Temperature:0°C to +40°C
Ambient Humidity:Up to 95% non-condensing
DC Power Supply
Series: NXGPRO Plus NCP
Input Voltage:90 – 290 V AC ³ph
Output Voltage (DC):±24 V/48 V DC
Rated Current Per:Cell ≥200 A
Power Rating:6 kW per cell
Efficiency:≥95%
Resilient Networks: -48 V/24 V
POWER SUPPLY I/O BOARD
GH180 NXGpro USER I/O board
Voltage Input:24 V DC (±10%)
Mounting: Secured within GM150 Cabinet
Operating Temperature: 0°C – 55°C
RUN/STOP: Operational mode of the board
Robicon Power Module
Voltage: 380–690V AC (±10%), 3-phase
Frequency: 50/60 Hz.
Nominal: 930V DC
Control Circuit Voltage: 24V DC (±15%)
Analog inputs :0–10V, 4–20mA
Temperature: -10°C to +50°C (derate 2% per °C above 40°C)
Humidity: <95% non-condensing
GH180 POWER CELL
Series: SINAMICS Perfect Harmony GH180
Type: Medium Voltage (MV) Power Cell
Phase Voltage:230/690 VAC input
Cell Output DC Link Voltage:750–950 VDC
Rated Current (Continuous):200–300 A
Switching Frequency:≤250 Hz
Efficiency:≥97%
Gen3 POWER CELL
Series: Gen3 Power Cell Family
Manufacturer: Siemens AG
Input Voltage (DC): 500–900 VDC
Output Voltage (AC): 400 VAC
Rated Power: Up to 315 kW
Efficiency: ≥97%
Phase Configuration: 3-phase output
Frequency: 50/60 Hz

Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.