Siemens Robicon

Power unit fuses

DC link/integrated power module
Input rectifiers
Output IGBTs in drives
Voltage Rating:690–1000 VDC
Current Rating (Cont.):450–700 A 
Interrupting Capacity:≥100–150 kA

Siemens Robicon

CELL WITH SUBMODULE

Series: Innomotics G5 Drive
Function: Power Submodule for MV Drive Systems
Current Rating (Cont.):45 A 
Voltage Rating:750 V DC
Overload Capacity:Up to 150% current for 60 s
Switching Frequency:Optimized ≤20 kHz 
Topology:IGBT Half-Bridge Module

Siemens Robicon

Air Filter Assembly

Airflow Capacity:≥15–40 m³/h
Filter Class:G4/F9 grade
Temp. Rating:−20°C to +70°C.
Pressure Drop:10–20 Pa
Material Standards UL94-V0 
Housing Material:Galvanized steel or high-density plastic

Siemens Robicon

Robicon MV Drive

Input Voltage:3-phase AC 6.6 kV
Output Frequency Range:0.0–120 Hz
Rated Power:5–40 MW
Output Voltage (Motor):3 kV to 6.6 kV
Overload Capacity:120% of rated current
Efficiency:>97%
Operating Temperature:0°C to +40°C
Ambient Humidity:Up to 95% non-condensing

Siemens Robicon

DC Power Supply

Series: NXGPRO Plus NCP
Input Voltage:90 – 290 V AC ³ph
Output Voltage (DC):±24 V/48 V DC
Rated Current Per:Cell ≥200 A
Power Rating:6 kW per cell
Efficiency:≥95%
Resilient Networks: -48 V/24 V

Siemens Robicon

POWER SUPPLY I/O BOARD

GH180 NXGpro USER I/O board 
Voltage Input:24 V DC (±10%) 
Mounting: Secured within GM150 Cabinet
Operating Temperature: 0°C – 55°C
RUN/STOP: Operational mode of the board

Siemens Robicon

Robicon Power Module

Voltage: 380–690V AC (±10%), 3-phase
Frequency: 50/60 Hz.
Nominal: 930V DC
Control Circuit Voltage: 24V DC (±15%)
Analog inputs :0–10V, 4–20mA
Temperature: -10°C to +50°C (derate 2% per °C above 40°C)
Humidity: <95% non-condensing

Siemens Robicon

GH180 POWER CELL

Series: SINAMICS Perfect Harmony GH180
Type: Medium Voltage (MV) Power Cell
Phase Voltage:230/690 VAC input
Cell Output DC Link Voltage:750–950 VDC
Rated Current (Continuous):200–300 A
Switching Frequency:≤250 Hz
Efficiency:≥97% 

Siemens Robicon

Gen3 POWER CELL

Series: Gen3 Power Cell Family
Manufacturer: Siemens AG
Input Voltage (DC): 500–900 VDC
Output Voltage (AC): 400 VAC
Rated Power: Up to 315 kW
Efficiency: ≥97%
Phase Configuration: 3-phase output
Frequency: 50/60 Hz

Siemens Robicon

control board

Voltage Inputs: 24 VDC
Current Draw: 3–5 A
Phase Control Response: <100
Operating Temp: 0–55°C
Humidity: Max 95% RH (non-condensing)

Siemens Robicon

Analog output module

Output Range: 4–20 mA
Current Regulation Accuracy: ±0.1% of full scale @ 20°C
Maximum Loop Resistance: ≤500 Ω
Minimum Load: Device must sustain ≥3.5 mA
Power Supply:24 VDC ±10%
Isolation: 500 VAC galvanic isolation
Operating Temperature: –20°C to +60°C 
Relative Humidity: 5–95% (non-condensing)

Siemens Robicon

Power Cell

Robicon Power Cell
Input Voltage:750–900 VDC
Rated Power: Up to 250 kVA
Continuous RMS: 260–300 A
AC Line-to-Line: 460 V ±10%
Switching Frequency: Up to 500 Hz
Operating: 0°C–55°C 
Storage/Derating: Up to 70°C

Siemens Robicon

Power Cell

Rated Load Current: 200 A
DC-Link Voltage: 750 V
Inverter Stage: ±375 V
Switching Frequency:500 Hz to 1 kHz
Continuous Power: 150 kVA 
Operating Temperature: 0°C ~ +40°C
Storage Temperature: -30°C ~ +70°C

Siemens Robicon

DCR Box Drive Control

ASI Robicon
Harmony NXG DCR Box Drive Control 
DC-Link Voltage Range: 510–930 VDC
Current Capacity: Up to 1,000 A
Protection Features:±2% tolerances
Operating Temperature: –10°C to +50°C

Siemens Robicon

Power Supply

Voltage: 3-Phase, 400–690 VAC
Frequency : 50/60 Hz (±5%)
Main Output: 24 VDC
Current Range: 10–20 A
Ripple Noise: <1%
Auxiliary Outputs: Possible ±15 VDC or 5 VDC
Input-to-Output Isolation: ≥2.5 kVAC
Efficiency: Typically ≥85% at full load

Siemens Robicon

Driver Board

Input Voltage: 24 VDC Control Power 
Output Signals: PWM switching 
Rated Current: ≤ 10 A 
Operating Voltage: 400–690 VAC (3-phase)
Switching Capability:60–100 Hz
Temperature Operating: 0°C–55°C

Siemens Robicon

Power unit

Component Type: Modular Power Cell
Nominal DC Voltage: 1,000–1,700 VDC
Input Current:50–200 A
AC Output Per Cell:690–1140V AC
Switching Frequency: 0–60 Hz
Insulation Testing: Rated for 5–15 kV
Legacy Status: Sinamics SL150

Siemens Robicon

User I/O module

Power supply NXGPRO +/-15 V
GH180 120 V DC user I/O module
Power supply kit 120 V DC for Inputboard On/Off

Siemens Robicon

Interface Board

GH180 NXGpro System 
Interface Board
6SR0960-0CC16-0AD0
A5E32168144

Siemens Robicon

CPU Board

GH180 Robicon 
Perfect Harmony PCA
SBC HARMONY NXGII
Series CPU Module

Siemens Robicon

NXGpro controller

GH180 NXGpro 
DCR controller 15 
cell 6SR0960-0CC15-0AD0
BOARD PRINTED CIRCUIT

Siemens Robicon

Control Board

NXGpro DCR 21
GH180 Robicon 
Cell 6SR0960-0CC21-0AD0

Siemens Robicon

Robicon I/O Breakout Board

Input Supply: 120V AC (±10%)
Frequency: 50/60 Hz (±5%)
Analog Inputs: Typically 0–10 V or 4–20 mA
Galvanic Isolation: ≥1500 V AC
Power Consumption:≤5 W (typical)

Siemens Robicon

KEYPAD INTERFACE

KEYPAD INTERFACE
W/ DISPLAY LCD
REPLACED BY A5E02363383