SNT501-13 S1

Optical ESB Slave Module

Shipping Information

  • For inventory products, we support same day shipping upon payment.
  • For urgent needs, we offer same-day shipping on most items for orders placed before 2:00 PM UTC+8 Simply mention your preferred next-day shipping when place the order, and your order will be prioritized to minimize downtime.
  • For indent items, typical turnaround is 1-3 weeks, depending on parts availability and scarcity.
Customs & Documentation
We prepare clear, order-specific documentation for every international shipment, including the commercial invoice, packing list and available product or compliance documents. Before dispatch, our logistics team confirms the consignee details, declared value, shipping terms and destination requirements with you. Tracking information is provided after shipment, helping your team prepare for import clearance with confidence.
Documents checked before dispatch · Shipment details confirmed · Global tracking provided
Payment
Payment is by bank wire only in RMB/CNY, GBP, EUR or USD. Amikon does not accept credit cards or provide credit terms. Cleared payment is required before shipment unless the written quotation expressly states otherwise.
Product Condition
Factory New These are new and current items that are procured directly from the manufacturer.
New In Sealed Package Parts are new. They have not been used and still have their original package seal intact.
New in Original Package These parts are new. The packages were not originally sealed by their original manufacturer.
Quantity
Mobile *
Country/Region *
E-mail *
Company
Content *
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Amikong please read our privacy policy.
  • 20+

    years in automation
  • ISO 9001

    certified quality system
  • 12 months

    amikon warranty
  • 2-hour reply

    from your account manager
  • Success Story

    solutions in action
PRODUCT DESCRIPTION

SNT501-13 S1 Optical ESB Slave Module

Yokogawa SNT501-13 S1 is the slave endpoint of a ProSafe-RS optical ESB extension. It receives the optical connection from the corresponding master and presents the electrical ESB connection to the SSB401 interface on the remote SNB10D safety node. The slave role is distinct from the master function performed by SNT401.

SNT401/SNT501 supports star and chain arrangements with up to two optical stages and a general total route of 5 km. The manufacturer lists 0.5 A consumption and minimum SENG/SCS revisions of R1.02. Redundant slaves are installed as a consecutive odd/even pair, and final 3 optical endpoints are matched together.
ACTUAL APPLICATIONS

Application fields for SNT501-13 S1

These broad application fields reflect the documented function and technical characteristics of SNT501-13 S1.
  • 01 · CHEMICALS

    Basic Chemistry and Petrochemical Resources

    Basic chemical fields and petrochemical resourcesInorganic chemical fields and specialty chemistry
  • 02 · POWER GENERATION

    Renewable Electricity and Conventional Energy

    Renewable electricity and conventional energy resourcesHydroelectric energy and thermal electricity fields
  • 03 · OIL & GAS

    Onshore Gas and Offshore Petroleum

    Onshore gas resources and conventional petroleumOffshore petroleum resources and natural gas

Technical specifications for SNT501-13 S1

  • Product Model
    SNT501-13 S1
  • Spare Model
    SNT501-13
  • Product Parameters
    Optical ESB Slave Module
  • In stock
    1 unit
  • Manufacturer
    Yokogawa
  • Current consumption
    0.5 A
  • Connection topologies
    Star and chain
  • Maximum optical stages
    2
  • Total optical distance
    Up to 5 km across two stages
  • Minimum SENG revision
    R1.02
  • Minimum SCS revision
    R1.02
  • Remote electrical ESB interface
    SSB401 on SNB10D
  • Matched optical master
    SNT401 with final suffix 3
  • Duplex mounting positions
    Adjacent odd/even slots
  • Optical connector
    LC; IEC 61754-20
  • Optical fiber specification
    Quartz single-mode; JIS C 6835 SSMA-9.3/125 or IEC 60793-2-50 B1.1
  • Optical fiber cores
    2 cores
  • Optical wavelength
    1.3 micrometres
  • Permissible optical path loss
    0 to 16 dB
  • Laser safety class
    Class 1; IEC 60825
View all additional

Alternative Names

SNT501-13 S1 ProSafe-RS optical ESB Optical ESB Slave Module
SYSTEM & REPLACEMENT CHECK

Information needed before ordering

Three direct checks to secure your system integration and minimize ordering risks.

Information

System integration Replacement check Manuals & support
SYSTEM INTEGRATION

Integrate SNT501-13 S1 within ProSafe-RS optical ESB

Use the slave at the SNB10D side of the optical extension and connect its electrical ESB cable to SSB401. The master and slave final suffixes must follow the manufacturer combination table; the final 3 slave is paired with the final 3 SNT401 master.
Budget 0.5 A for each installed slave and count the total length across the optical stages. The standard two-stage limit is 5 km; only the specifically documented Vnet/IP R1.03-or-later arrangement permits the longer 10 km combined path.
Keep the duplex slave pair in consecutive slots, with ESB bus 1 on the odd slot and bus 2 on the even slot. Match both suffixes and retain the SNT10D empty-slot requirements when the local ambient reaches 60 to 70 C.

Features:

  • Current consumption: 0.5 A
  • Connection topologies: Star and chain
  • ProSafe-RS optical ESB
Use SNT501-13 S1 only within the documented ProSafe-RS optical ESB arrangement and applicable installation instructions.
INTERCHANGEABILITY

Replace SNT501-13 S1 within ProSafe-RS optical ESB

Confirm that the removed module is the slave SNT501-13 S1 and identify the upstream master before ordering the spare. A matching enclosure or connector count does not distinguish the slave role from SNT401 master hardware.
Label the SSB401 electrical cable and each redundant optical path. Preserve the established bus 1/bus 2 slot assignment and protect the optical ends during the exchange so that the final 3 pairing and electrical bus routing remain unchanged.
Following installation, check the remote SNB10D availability and each redundant ESB path through the approved maintenance procedure. Revisit system revision and total route length if a path was extended or the upstream master was also replaced.

Features:

  • SNT501-13 S1 complete suffix
  • Duplex mounting positions: Adjacent odd/even slots
  • Master/slave role and installed optical paths retained
Use SNT501-13 S1 only within the documented ProSafe-RS optical ESB arrangement and applicable installation instructions.
DOCUMENTATION STATUS

Browse the Manuals, Datasheets, Official Documents, Links

Important Notice: The linked files are Amikong-hosted reference documents. Match their product identity and scope to the supplied assembly, and consult the applicable manufacturer instructions before use. Accessories and additional documents are included only when expressly listed in the quotation.

Features:

  • Exact-model technical data for SNT501-13 S1
  • Document applicability checked against the complete identity
  • Directory links by subcategory and brand
Documentation for SNT501-13 S1 must match the installed product identity and supplied configuration.

Important notice

Manuals, software, firmware, cables, calibration data and accessories are included only when listed in the quotation. AMIKON is an independent supplier and is not affiliated with or authorised by the manufacturer.
This content has been produced using multiple sources. Takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
BUYER INFORMATION

Commercial terms without hidden steps

Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • 01

    Shipping & delivery

    Dispatch
    Eligible stock: same / next day
    Carriers
    DHL, FedEx or UPS
    Ship from
    Xiamen, China
    Product size
    3.28 x 13.00 x 14.25 cm
    Net weight
    0.30 kg
  • 02

    Payment & customs

    Payment
    Bank transfer (T/T)
    Currencies
    USD · EUR · GBP · RMB
    Credit cards
    Not accepted
    HS reference
    8517622990
    Origin
    Japan
  • 03

    Warranty & returns

    Warranty
    12 months from AMIKON
    Inspection
    Label, condition and packing checks
    Returns
    Prior RMA authorisation required
    Compatibility
    Confirm before order
    OEM warranty
    Does not apply
Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • Part checked

    Full suffix recorded
  • Condition checked

    Label and appearance
  • Packing checked

    Antistatic protection
  • Tracking supplied

    Established couriers
  • Sandy Lin

    Dedicated account manager · 15+ years
FREQUENTLY ASKED QUESTIONS

Questions buyers ask about SNT501-13 S1

Direct answers about identity, compatibility, stock, warranty, payment and shipping.
  • What is the remote electrical connection of SNT501-13 S1?

    SNT501-13 S1 connects by electrical ESB cable to SSB401 on the SNB10D safety node after receiving the optical path from the matching master.
  • Can an SNT401 be fitted in place of SNT501-13 S1?

    SNT501-13 S1 is a slave endpoint and SNT401 is the master. Preserve the assigned role rather than selecting by physical similarity.
  • Which master is listed for the final 3 slave SNT501-13 S1?

    Yokogawa pairs the final 3 SNT501 version of SNT501-13 S1 with a final 3 SNT401 master in the optical combination table.
  • How many optical stages can precede SNT501-13 S1?

    The SNT401/SNT501 arrangement serving SNT501-13 S1 permits no more than two connecting stages, subject to the combined-distance limit.
  • Does each slave in a duplex SNT501-13 S1 arrangement consume 0.5 A?

    Yes. The family specification lists 0.5 A per repeater, so both modules must be included when budgeting a duplex SNT501-13 S1 pair.
  • Can SNT501-13 S1 use the longer Vnet/IP distance automatically?

    The general limit is 5 km total. The 10 km combined-path allowance associated with SNT501-13 S1 requires the stated Vnet/IP R1.03-or-later arrangement.
  • How should the remote-node role appear on a SNT501-13 S1 quotation?

    List SNT501-13 S1 as the optical ESB slave and identify the upstream master. State the required quantity and style so that the quotation does not substitute a master module.
  • What should receiving staff compare for SNT501-13 S1?

    For SNT501-13 S1, compare the full slave label, style, optical suffix and condition with the purchase order, and keep any cables or separately quoted accessories identified apart from the module.
READY TO VERIFY YOUR PART?

Get a SNT501-13 S1 quote with price, lead time and revision check.

Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: Amikon Limited sells new and surplus products and develops channels for purchasing such products. Amikon Limited is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because Amikon Limited is not an authorized distributor of this product, the Original Manufacturer's warranty does not apply. Amikon Limited is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.
Product

Product Browsing History