Close Menu
Get Parts Quote
Name
Company *
WhatsApp / WeChat (For Faster Quote) *
Email *
Address
City
State / Province / Region
Zipcode
Country
Quantity *
Part Number *
Manufacturer
Preferred Condition
Additional Information
Cancel
In Stock
Fast Shipping Available
Yokogawa PH4F-120-10E-N
· Product image is representative; revision or series may vary. Contact us to request a specific version.
Ships by Wednesday, October 7

PH4F-120-10E-N

HF-resistant pH sensor

Shipping Information

  • For inventory products, we support same day shipping upon payment.
  • For urgent needs, we offer same-day shipping on most items for orders placed before 2:00 PM UTC+8 Simply mention your preferred next-day shipping when place the order, and your order will be prioritized to minimize downtime.
  • For indent items, typical turnaround is 1-3 weeks, depending on parts availability and scarcity.
Customs & Documentation
We prepare clear, order-specific documentation for every international shipment, including the commercial invoice, packing list and available product or compliance documents. Before dispatch, our logistics team confirms the consignee details, declared value, shipping terms and destination requirements with you. Tracking information is provided after shipment, helping your team prepare for import clearance with confidence.
Documents checked before dispatch · Shipment details confirmed · Global tracking provided
Payment
Payment is by bank wire only in RMB/CNY, GBP, EUR or USD. Amikon does not accept credit cards or provide credit terms. Cleared payment is required before shipment unless the written quotation expressly states otherwise.
Product Condition
Factory New These are new and current items that are procured directly from the manufacturer.
New In Sealed Package Parts are new. They have not been used and still have their original package seal intact.
New in Original Package These parts are new. The packages were not originally sealed by their original manufacturer.
Quantity
Mobile *
Country/Region *
E-mail *
Company
Content *
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Amikong please read our privacy policy.
  • 20+

    years in automation
  • ISO 9001

    certified quality system
  • 12 months

    amikon warranty
  • 2-hour reply

    from your account manager
  • Success Story

    solutions in action
PRODUCT DESCRIPTION

PH4F-120-10E-N HF-resistant pH sensor

PH4F-120-10E-N is an HF-resistant pH sensor for fluoride-bearing and corrosive process solutions, with a 120 mm insertion length and integral cable. The model identity, electrical limits and compatible system must be confirmed before replacement or commissioning.
ACTUAL APPLICATIONS

Application context for PH4F-120-10E-N

The applications below show typical industry settings, application scenarios, application areas and equipment for PH4F-120-10E-N. Confirm the exact product configuration before use.
  • 01 · WATER & WASTEWATER

    Hydrofluoric-acid resistant pH measurement

    Plant areas servedChemical neutralization basinsFluoride treatment skids
  • 02 · CHEMICAL PROCESSING

    Corrosive process pH monitoring

    Process unitsAcid etching bathsFluoride-bearing process vessels
  • 03 · METALLURGY & METALS

    Pickling-line solution monitoring

    Production areasAcid recovery tanksRinse and neutralization lines

Technical specifications for PH4F-120-10E-N

  • Product Model
    PH4F-120-10E-N
  • Product Parameters
    HF-resistant pH sensor
  • In stock
    1 unit
  • Manufacturer
    Yokogawa
  • Measuring range
    pH 2 to 11
  • Insertion length
    120 mm
  • Cable length
    10 m
  • Temperature range
    0 to 80 °C
  • Maximum pressure
    1.6 MPa at 25 °C
  • Reference system
    Double-junction reference
  • Wetted glass
    HF-resistant pH glass
  • Body material
    PPS resin
  • Junction material
    Porous PTFE
  • Temperature element
    Pt1000
  • Cable termination
    Dedicated Yokogawa analyzer leads
  • Compatible analyzers
    FLXA and PH450 families per wiring table
  • Installation connection
    Threaded holder or flow assembly
  • Process service
    Fluoride-containing aqueous solutions
View all additional

Alternative Names

PH4F 120 10E N PH4F pH sensors HF-resistant pH sensor Yokogawa HF-resistant pH sensor
SYSTEM & REPLACEMENT CHECK

Information needed before ordering

Three direct checks to secure your system integration and minimize ordering risks.

Information

System integration Replacement check Manuals & support
SYSTEM INTEGRATION

Match PH4F-120-10E-N to the installed PH4F pH sensors

Yokogawa PH4F-120-10E-N is a HF-resistant pH sensor for the PH4F pH sensors. Its exact article suffix determines the supported interface, signal or communication function and the approved companion equipment.
Engineering should compare temperature range (0 to 80 °C), maximum pressure (1.6 MPa at 25 °C) and reference system (Double-junction reference) with the installed system design. Confirm connector keying, addressing and configuration-tool support before connection.
Use the manufacturer documentation for the complete wiring and configuration sequence. Validate communication, signal conversion or control response with the connected equipment, then archive measured results and the final configuration with the asset record.

Features:

  • Exact identity: PH4F-120-10E-N
  • Product class: HF-resistant pH sensor
  • Family: PH4F pH sensors
The Yokogawa PH4F-120-10E-N requires documented system integration before energising the equipment.
REPLACEMENT CONTROL

Verify the complete PH4F-120-10E-N identity before exchange

Replace PH4F-120-10E-N only after matching the complete article code, HF-resistant pH sensor, installed PH4F pH sensors role and documented hardware or firmware revision. Similar housings and related family numbers do not establish functional interchangeability.
Photograph the nameplate, keyed connectors, terminal numbering, cable routing, shields, earth points and adjacent modules. Export the applicable controller, HMI, drive or network configuration and record addresses, parameters and diagnostic messages before removal.
After fitting the verified article, restore the controlled configuration and check every affected signal or communication path. Review status indications and diagnostic buffers, run the documented functional test at a safe operating point and retain the final acceptance record.

Features:

  • Exact identity: PH4F-120-10E-N
  • Product class: HF-resistant pH sensor
  • Family check: PH4F pH sensors
The Yokogawa PH4F-120-10E-N requires documented replacement verification before energising the equipment.
DOCUMENTATION STATUS

Browse the Manuals, Datasheets, Official Documents, Links

Important Notice: Official documents are provided through manufacturer links. Accessories, manuals, cables, calibration data, software and certificates are included only when listed in the quotation.

Features:

  • Technical values prepared for PH4F-120-10E-N
  • Yokogawa PH4F pH sensors references reviewed
  • Exact Yokogawa identity required before service
Documentation for Yokogawa PH4F-120-10E-N must match the installed equipment; confirm document applicability before service.

Important notice

Manuals, software, firmware, cables, calibration data and accessories are included only when listed in the quotation. AMIKON is an independent supplier and is not affiliated with or authorised by the manufacturer.
This content has been produced using multiple sources. Takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
BUYER INFORMATION

Commercial terms without hidden steps

Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • 01

    Shipping & delivery

    Dispatch
    Eligible stock: same / next day
    Carriers
    DHL, FedEx or UPS
    Ship from
    Xiamen, China
    Packed size
    30 × 10 × 8 cm
    Shipping weight
    0.50 kg
  • 02

    Payment & customs

    Payment
    Bank transfer (T/T)
    Currencies
    USD · EUR · GBP · RMB
    Credit cards
    Not accepted
    HS reference
    90278000
    Origin
    Japan
  • 03

    Warranty & returns

    Warranty
    12 months from AMIKON
    Inspection
    Label, condition and packing checks
    Returns
    Prior RMA authorisation required
    Compatibility
    Confirm before order
    OEM warranty
    Does not apply
Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • Part checked

    Full suffix recorded
  • Condition checked

    Label and appearance
  • Packing checked

    Antistatic protection
  • Tracking supplied

    Established couriers
  • Sandy Lin

    Dedicated account manager · 15+ years
FREQUENTLY ASKED QUESTIONS

Questions buyers ask about PH4F-120-10E-N

Direct answers about identity, compatibility, stock, warranty, payment and shipping.
  • Receiving PH4F-120-10E-N for integration shutdown: check pH 2 to 11 measuring range?

    For PH4F-120-10E-N during shutdown preparation, a system integrator should match measuring range (pH 2 to 11) and insertion length (120 mm) to the installed PH4F pH sensors design. A mismatch can prevent correct integration even when the hardware appears similar.
  • Integration shutdown: does PH4F-120-10E-N match 120 mm?

    For shutdown preparation, identify PH4F-120-10E-N by the combined specification: insertion length is 120 mm, while cable length is 10 m. A system integrator should confirm both values rather than relying on the family name or enclosure.
  • Confirming PH4F-120-10E-N cable length during integration shutdown?

    Before wiring or mounting PH4F-120-10E-N, a system integrator should verify the installation supports cable length of 10 m and preserves the documented temperature range of 0 to 80 °C. Record this check in the shutdown preparation work pack.
  • PH4F-120-10E-N temperature range: 0 to 80 °C or another value — integration shutdown?

    During shutdown preparation, a system integrator should commission PH4F-120-10E-N under a controlled load or signal and confirm temperature range reaches 0 to 80 °C. Cross-check maximum pressure against 1.6 MPa at 25 °C, then save the measured result for engineering acceptance.
  • PH4F-120-10E-N selection check for integration shutdown: maximum pressure?

    During shutdown preparation, a system integrator should isolate the circuit, compare the actual maximum pressure with the PH4F-120-10E-N specification of 1.6 MPa at 25 °C, and inspect the related reference system requirement (Double-junction reference). This separates a module fault from a supply, wiring, or configuration issue.
  • Integration shutdown evidence for PH4F-120-10E-N: reference system?

    For shutdown preparation, the PH4F-120-10E-N service record should state reference system as Double-junction reference and retain wetted glass at HF-resistant pH glass. These values give a system integrator a repeatable baseline for later replacement and fault diagnosis.
  • PH4F-120-10E-N wetted glass for distributor integration shutdown?

    For a system integrator's shutdown preparation request, the quotation should identify the complete PH4F-120-10E-N code and confirm wetted glass (HF-resistant pH glass) together with body material (PPS resin). The distributor should flag any revision or substitute that changes either requirement.
  • PH4F-120-10E-N at PPS resin: MRO integration shutdown concern?

    For a system integrator's shutdown preparation requirement, check the delivered PH4F-120-10E-N label and order code, then verify body material is PPS resin and measuring range is pH 2 to 11. Photograph the label and connectors before acceptance so purchasing and maintenance share the same identity record.
READY TO VERIFY YOUR PART?

Get a PH4F-120-10E-N quote with price, lead time and revision check.

Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: Amikon Limited sells new and surplus products and develops channels for purchasing such products. Amikon Limited is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because Amikon Limited is not an authorized distributor of this product, the Original Manufacturer's warranty does not apply. Amikon Limited is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.
Product

Product Browsing History