ABB are a market leading producer of power & automation technologies that enhance performance and reduce environmental impact for industries worldwide.
Amikon Limited stock and supply ABB motors, drives, programmable logic controllers (PLCs), power electronics and Robot spare parts and Discontinued card parts, motion and obsolete including variable speed drives, DC drives, PLCs and general automation spares.
ABB are a market leading producer of power & automation technologies that enhance performance and reduce environmental impact for industries worldwide.
Amikon Limited stock and supply ABB motors, drives, programmable logic controllers (PLCs), power electronics and Robot spare parts and Discontinued card parts, motion and obsolete including variable speed drives, DC drives, PLCs and general automation spares.
ACS600 Fiber-optic communication board
MAIN CIRCUIT INTERFACE BOARD
GIVES CONTROL COMMANDS
SENDS MEASUREMENT SIGNALS
Number: Up to 16 channels
Connectors: ST/SC-type
Isolation Voltage: 2500 V
PCB MATCHING BOARD
CIRCUIT BOARD MODULE
58908096
Operating Voltage: 24 V DC (±10%)
Power Consumption: <5 W
Analog: +/-10 V DC or 4–20 mA
Digital: 24 V DI/DO
Remote Monitoring
Communication Board Kit
Input Voltage: 24 V DC (±20%)
Power Consumption: < 5 W
Ethernet Port:10/100 Mbps RJ45
Serial Port(s):RS-485 / RS-232
Input Voltage: 24 V DC
PROFIBUS DP: Up to 12 Mbps
Modbus RTU: Typically 9600 bps – 115.2 kbps
Operating Temperature:-25°C to +70°C (-13°F to +158°F)
Storage Temperature:-40°C to +85°C (-40°F to +185°F)
Humidity:5% – 95% (non-condensing)
Typical current consumption: < 200 mA
Power Supply:24 V DC
Ethernet Port (TCP):- 10/100 Mbps RJ45
Modbus RTU (RS485)
Modbus TCP (TCP/IP) compliance
Isolation:1500 V AC
Operating Temp: -25°C to +70°C
High Voltage Isolation: Up to 2–4 kV
Resistance Range: 10 Ω–1 MΩ
Power Rating: 0.25–2 W
Voltage Rating: 50–500 V DC/AC
Temperature Range: -55°C to +150°C
RoHS: Lead-free manufacturing.
UL 94V-0: Flame-retardant encapsulation
Signal termination for 4–20 mA
Current: 4–20 mA
Voltage: 0–10 V DC, ±5 V DC
Temperature: RTD (Pt100/1000)
Cable Length: 10 meters (indicated by "-10" suffix)
Bend Radius: ≥8x cable diameter
Operating Temperature: -40°C to +105°C (-40°F to +221°F)
Number of Channels: 8 or 16
Current: 4–20 mA
Voltage: 0–10 V DC, ±10 V DC
Channel-to-channel: ≥250 V AC
Field-to-system: 1500 V AC
Supply Voltage: 24 V DC (±10%)
Power Consumption: ≤5 W
ABB infi-90 Termination Loop Cable
Gauge: 18–24 AWG
Voltage Rating: ≤60 V DC
Operating Temperature: -20°C to +70°C (-4°F to +158°F)
Humidity: 5–95% RH (non-condensing)
Function:4 AI: U, I
Number of Analog Configurable I/Os:0
Analog Inputs:4
Input Signal:U, I
Resolution:Analog Input 12 bit
Connection Type:Pluggable
Degree of Protection:Housing IP20
Ambient Air Temperature:
Operation 0 ... +60 °C
Storage -40 ... +70 °C
Input: 200–690 V AC
Output: Matches input voltage
Power Range:0.75 kW to 560 kW
Current Rating:1,300 A
Torque accuracy: ±5% (SLVC mode)
Speed control range: 1:100 (SLVC)
Input: 200–690 V AC
Output: Matches input voltage
Power Range:0.75 kW to 560 kW
Current Rating:1,300 A
Torque accuracy: ±5% (SLVC mode)
Speed control range: 1:100 (SLVC)
Input: 200–690 V AC
Output: Matches input voltage
Power Range:0.75 kW to 560 kW
Current Rating:1,300 A
Torque accuracy: ±5% (SLVC mode)
Speed control range: 1:100 (SLVC)
Max Collector-Emitter Voltage:1000 V
Rated Collector Current:1700 A
Max Pulsed Current :3000–3400 A
Gate-Emitter Voltage:±20 V
Switching Frequency Range:0.5 kHz – 5 kHz
High speed switching
Voltage drive
Low Inductance module structure
Inverter for Motor Drive
AC and DC Servo Drive Amplifier
Uninterruptible Power Supply
Industrial machines, such as Welding machines
Max Collector-Emitter Voltage:1400 V
Rated Collector Current:120 A
Max Power Dissipation:400–600 W
Gate-Emitter Voltage: ±20 V
Switching Frequency Range:1 kHz – 20 kHz
Temperature:150°C – 175°C
Power Supply: 24 VDC (±10%) or 110–240 VAC
1–2 x RJ45 Ethernet ports.
Serial ports (RS-232/485) for legacy devices
Fiber-optic or coaxial connectors
Operating Temperature: -20°C to +60°C
Humidity: 5–95% non-condensing
Rated Load: Up to 1000 kN
Overload Protection: 200% of rated capacity
Accuracy: ±0.1% FS (full-scale linearity).
Output Signal Analog: 4–20 mA (2-wire), ±10V DC
Output Signal Digital: Optional Profibus DP, Modbus RTU
Excitation Voltage: 10–30V DC
Frequency Response: ≤1 kHz
Compression/Tension: Up to 500 kN
Overload Protection: 150% of rated capacity
Accuracy: ±0.1% of full scale (FS) linearity error
Output Signal :Analog: 4–20 mA or ±10V DC
Rated Excitation Voltage: 10–15V DC
Bridge Resistance: 350 Ω ±1%.
Operating Temperature:
-40°C to +120°C (-40°F to +248°F)
Analog Inputs: 8–16 channels
Voltage Ranges: ±10V, 0–10V, 1–5V
Current Ranges: 4–20 mA, 0–20 mA
Analog Outputs: 4–8 channels
Voltage: 0–10V, ±10V
Current: 4–20 mA
Resolution:16-bit ADC/DAC
IGCT MODULE
4500V
91MM
ALT PART NUMBER: 5SHY 3545L0016
DC Bus Voltage: 510–930 V DC
Output Current: Up to 600 A
Operating Temperature: -10°C to +50°C
Humidity: 5–95% non-condensing
ABB SYNCHROTACT 4 multi motor
Voltage Inputs: 3-phase AC, 110–690 V
Frequency Range: 45–65 Hz
Frequency Matching: Precision ±0.01 Hz
Voltage Matching: ≤ ±1% deviation
Operating Temperature: -25°C to +55°C
Input Voltage Range: 230 V AC to 690 V AC
Frequency Range: 0–300 Hz
Efficiency: ≥ 98% under standard load conditions
Operating Temperature: -10°C to +55°C
Storage Temperature: -40°C to +70°C
Humidity: 5% to 95% (non-condensing)
ACS880 frequency converter drive board
Operating Voltage: 24 Vdc
Analog Inputs: 0–10 V or 4–20 mA
Operating Temperature: -10°C to +50°C
Humidity: 5–95% non-condensing
Output Power: 160 kW (215 HP) at 400 V AC.
Output Current: 302 A
Input: 380–480 V AC, 3-phase (±10%), 50/60 Hz.
Output: 0–480 V AC
Efficiency: ≥97% (typical at full load)
Control I/O: 5x analog inputs (2x 0–10 V / 0–20 mA)
Switching Frequency: 1–8 kHz
Input Voltage: 24 VDC (±10%)
Analog Inputs: 0–10 VDC / 4–20 mA
Fieldbus Support: PROFIBUS DP
Operating Temperature: -25°C to +55°C (-13°F to +131°F).
Humidity: Up to 95% non-condensing
Input Voltage: 24 VDC (±10%)
Analog Inputs: 0–10 VDC / 4–20 mA
Fieldbus Support: PROFIBUS DP
Operating Temperature: -25°C to +55°C (-13°F to +131°F).
Humidity: Up to 95% non-condensing
Input Voltage: 24 VDC (±10%)
Analog Inputs: 0–10 VDC or 4–20 mA
Operating Temperature: -25°C to +55°C (-13°F to +131°F)
Humidity: Up to 95% non-condensing.
Vibration Resistance: 5–150 Hz
Input Voltage: 24 VDC (±10%)
Analog Inputs: 0–10 VDC or 4–20 mA
Operating Temperature: -25°C to +55°C (-13°F to +131°F).
Humidity: Up to 95% non-condensing.
Vibration Resistance: 5–150 Hz
RAM: Typically 512 MB to 1 GB
Supply Voltage: 24 VDC (±10%).
Power Consumption: Typically 5–10 W
Operating Temperature: -20°C to +70°C (-4°F to +158°F).
Storage Temperature: -40°C to +85°C (-40°F to +185°F).
Humidity: 5–95% non-condensing
RAM: Typically 512 MB to 1 GB
Flash Memory: 2–4 GB
Supply Voltage: 24 VDC (±10%).
Power Consumption: Typically 5–10 W
Operating Temperature: -20°C to +70°C (-4°F to +158°F).
Storage Temperature: -40°C to +85°C (-40°F to +185°F).
Humidity: 5–95% non-condensing
24 binary outputs with enclosed relays (NO contacts)
Current carrying capacity of the relays: max. 1 A
Channel-by-channel isolation of the outputs
Module is capable of redundant operation
Monitoring of the module
Counter for switching cycles (channel by channel)
16 analog outputs, output signal 0/4 ... 20 mA,
channel-by-channel configuration
Load: max. 700 Ohm
Monitoring of loads
Channel-by-channel isolation of outputs
Module is capable of redundant operation
Digital communication with field devices according to
HART protocol (Version 5.0 / 5.1)
Monitoring of modules