Control Board
Remote Keypad Mount Kit
Interface Option
Keypad Power Supply:24 VDC
Max Cable Length: ≤ 10 m
Operating Temperature: -25°C to +55°C
Humidity: ≤ 95% RH
CHARGING CONTROL BOARD
RS-485 or CAN Bus
Modbus RTU/TCP compatibility
Overvoltage/Undervoltage Protection
Overcurrent Protection
Short-Circuit Protection
Temperature Monitoring with automatic derating
Controller Module
Clock Speed: 800 MHz – 1.5 GHz
RAM: 2 GB DDR4
Operating Voltage: 24 V DC
Power Consumption: ≤18 W
Isolation: ≥3000 V AC
Ethernet Interfaces:2× Gigabit ports
Discrete I/O: 12–24 V DC
Analog Interfaces: 4–8 channels
Motherboard
Input Voltage: 24 V DC
Backplane Power: 5 V DC
RAM Slots: 2× DDR4 SO-DIMM
Storage: Integrated 16 GB flash
Operating: -40°C to +70°C
Humidity: 5–95% non-condensing
MTBF: >250,000 hours
Processor Module
Operating Voltage: 24 V DC
Power Consumption: <12 W
Input Protection:±40 V peak transient
Digital I/O: 16 channels
Analog I/O (Optional): 4 channels
Ethernet: 2× 10/100 Mbps ports
Serial: RS-232/RS-485 for legacy devices
Fieldbus: PROFIBUS DP
Control Board
Operating Voltage: 24 V DC
Power Consumption: ≤15 W
Voltage Range: 0–10 V DC
Resolution: 12-bit
Channels: ≥8 opto-isolated
Input Signal Level: 24 V DC
ADAPTER BOARD
Electrical Rating:24V DC (±10%)
Compatibility:ACS880-04
Communication Ports:RS485
Operation: 0°C to +55°C
Storage: -40°C to +85°C
OUTPUT FILTER BOARD
68295505
System Voltage:380–500V AC
Frequency Range:10–20 kHz
Filter Topology:LC filters (inductors + capacitors)
Operating Temperature:-15°C to +50°C
ACS880 Liquid-Cooled Multi-Drives
VARISTOR UNIT
ACS600 Single Drives
VARISTOR UNIT
Protects ACS600 single drives
Protection DutyAC Input Line Transients
Voltage Rating:380–500V AC (50/60 Hz)
Energy Absorption:≥ 120 joules
Clamping Voltage:1.3–1.5x V
Maximum Continuous Voltage:550 V DC link
PROGRAMMED MODULE
PROGRAMMED
ZINT-571
3AXD50000037997P
Key Function:DCS/SCADA
integrated safety relays
Voltage Supply:24V DC (±10%)
Operating Temp.:-25°C to +60°C
PROGRAMMED MODULE
CCU-24 SP
PROGRAMMED
ZINT-571P
3AXD50000037997P
Key Function:DCS/SCADA
integrated safety relays
Voltage Supply:24V DC (±10%)
Operating Temp.:-25°C to +60°C
CONTROL UNIT
Input Voltage:24V DC (±15%)
Fieldbus: PROFIBUS DP, PROFINET
Digital I/O: ≥16 configurable
Analog I/O: 2x ±10V/4–20mA inputs
Safety I/O: Safe Torque Off
Compatible Drives:ABB ACS880 series
RPBA/PXG01 I/O Boards
Operating Environment:-15°C to +55°C
MEMORY UNIT KIT
MEMORY UNIT KIT
AINF6 3.42 +ZMU-03 SP
Signal Compatibility: 4–20 mA, 0–10 V, ±10 V
Resolution: 16-bit precision
Storage Capacity:2–32 GB
Analog Input Module (AINF6): 24 V DC (±10%)
Voltage Range:300–500 V AC
Main Interface Board
3AUA0000031096
ACS800 Main Board
frequency converter communication board
Auxiliary Power Input: 24 V DC (±10%)
Power Consumption: ≤5 W (typical)
Digital I/O:24 V DC
Analog Inputs: 0–10 V or 4–20 mA
Interface Main Circuit Board
ACS600 Fiber-optic communication board
MAIN CIRCUIT INTERFACE BOARD
GIVES CONTROL COMMANDS
SENDS MEASUREMENT SIGNALS
Number: Up to 16 channels
Connectors: ST/SC-type
Isolation Voltage: 2500 V
Matching Board
PCB MATCHING BOARD
CIRCUIT BOARD MODULE
58908096
Operating Voltage: 24 V DC (±10%)
Power Consumption: <5 W
Analog: +/-10 V DC or 4–20 mA
Digital: 24 V DI/DO
IGBT MODULE KIT SP
IGBT MODULE KIT SP
IGBT MODULE ED3 225A/1700V SP
Semiconductor spare part kit
to be used with ACS880-104 modules
Communication Board Kit
Remote Monitoring
Communication Board Kit
Input Voltage: 24 V DC (±20%)
Power Consumption: < 5 W
Ethernet Port:10/100 Mbps RJ45
Serial Port(s):RS-485 / RS-232
Surface Mounting Kit
Installation Type: Surface mounting
Aluminum or stainless steel
IP Rating: IP65
Adapter plate: 300 x 220 mm
Depth Adjustment:1–5 mm
Frequency Converter Communication Board
Input Voltage: 24 V DC
PROFIBUS DP: Up to 12 Mbps
Modbus RTU: Typically 9600 bps – 115.2 kbps
Operating Temperature:-25°C to +70°C (-13°F to +158°F)
Storage Temperature:-40°C to +85°C (-40°F to +185°F)
Humidity:5% – 95% (non-condensing)
Typical current consumption: < 200 mA
Softstarter
Product No. : PSTX300-600-70
Product Type : Softstarter
Current Rating : 300 - 300A
Main Voltage : 600 - 208 - 600V 50/60 Hz
Supply Voltage : 70 - 100 - 250V 50/60 Hz
Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.