ABB are a market leading producer of power & automation technologies that enhance performance and reduce environmental impact for industries worldwide.
Amikon Limited stock and supply ABB motors, drives, programmable logic controllers (PLCs), power electronics and Robot spare parts and Discontinued card parts, motion and obsolete including variable speed drives, DC drives, PLCs and general automation spares.
ABB are a market leading producer of power & automation technologies that enhance performance and reduce environmental impact for industries worldwide.
Amikon Limited stock and supply ABB motors, drives, programmable logic controllers (PLCs), power electronics and Robot spare parts and Discontinued card parts, motion and obsolete including variable speed drives, DC drives, PLCs and general automation spares.
Power Supply: 24 VDC (±10%) or 110–240 VAC
1–2 x RJ45 Ethernet ports.
Serial ports (RS-232/485) for legacy devices
Fiber-optic or coaxial connectors
Operating Temperature: -20°C to +60°C
Humidity: 5–95% non-condensing
Rated Load: Up to 1000 kN
Overload Protection: 200% of rated capacity
Accuracy: ±0.1% FS (full-scale linearity).
Output Signal Analog: 4–20 mA (2-wire), ±10V DC
Output Signal Digital: Optional Profibus DP, Modbus RTU
Excitation Voltage: 10–30V DC
Frequency Response: ≤1 kHz
Compression/Tension: Up to 500 kN
Overload Protection: 150% of rated capacity
Accuracy: ±0.1% of full scale (FS) linearity error
Output Signal :Analog: 4–20 mA or ±10V DC
Rated Excitation Voltage: 10–15V DC
Bridge Resistance: 350 Ω ±1%.
Operating Temperature:
-40°C to +120°C (-40°F to +248°F)
Analog Inputs: 8–16 channels
Voltage Ranges: ±10V, 0–10V, 1–5V
Current Ranges: 4–20 mA, 0–20 mA
Analog Outputs: 4–8 channels
Voltage: 0–10V, ±10V
Current: 4–20 mA
Resolution:16-bit ADC/DAC
IGCT MODULE
4500V
91MM
ALT PART NUMBER: 5SHY 3545L0016
DC Bus Voltage: 510–930 V DC
Output Current: Up to 600 A
Operating Temperature: -10°C to +50°C
Humidity: 5–95% non-condensing
ABB SYNCHROTACT 4 multi motor
Voltage Inputs: 3-phase AC, 110–690 V
Frequency Range: 45–65 Hz
Frequency Matching: Precision ±0.01 Hz
Voltage Matching: ≤ ±1% deviation
Operating Temperature: -25°C to +55°C
Input Voltage Range: 230 V AC to 690 V AC
Frequency Range: 0–300 Hz
Efficiency: ≥ 98% under standard load conditions
Operating Temperature: -10°C to +55°C
Storage Temperature: -40°C to +70°C
Humidity: 5% to 95% (non-condensing)
ACS880 frequency converter drive board
Operating Voltage: 24 Vdc
Analog Inputs: 0–10 V or 4–20 mA
Operating Temperature: -10°C to +50°C
Humidity: 5–95% non-condensing
Output Power: 160 kW (215 HP) at 400 V AC.
Output Current: 302 A
Input: 380–480 V AC, 3-phase (±10%), 50/60 Hz.
Output: 0–480 V AC
Efficiency: ≥97% (typical at full load)
Control I/O: 5x analog inputs (2x 0–10 V / 0–20 mA)
Switching Frequency: 1–8 kHz
Input Voltage: 24 VDC (±10%)
Analog Inputs: 0–10 VDC / 4–20 mA
Fieldbus Support: PROFIBUS DP
Operating Temperature: -25°C to +55°C (-13°F to +131°F).
Humidity: Up to 95% non-condensing
Input Voltage: 24 VDC (±10%)
Analog Inputs: 0–10 VDC / 4–20 mA
Fieldbus Support: PROFIBUS DP
Operating Temperature: -25°C to +55°C (-13°F to +131°F).
Humidity: Up to 95% non-condensing
Input Voltage: 24 VDC (±10%)
Analog Inputs: 0–10 VDC or 4–20 mA
Operating Temperature: -25°C to +55°C (-13°F to +131°F)
Humidity: Up to 95% non-condensing.
Vibration Resistance: 5–150 Hz
Input Voltage: 24 VDC (±10%)
Analog Inputs: 0–10 VDC or 4–20 mA
Operating Temperature: -25°C to +55°C (-13°F to +131°F).
Humidity: Up to 95% non-condensing.
Vibration Resistance: 5–150 Hz
RAM: Typically 512 MB to 1 GB
Supply Voltage: 24 VDC (±10%).
Power Consumption: Typically 5–10 W
Operating Temperature: -20°C to +70°C (-4°F to +158°F).
Storage Temperature: -40°C to +85°C (-40°F to +185°F).
Humidity: 5–95% non-condensing
RAM: Typically 512 MB to 1 GB
Flash Memory: 2–4 GB
Supply Voltage: 24 VDC (±10%).
Power Consumption: Typically 5–10 W
Operating Temperature: -20°C to +70°C (-4°F to +158°F).
Storage Temperature: -40°C to +85°C (-40°F to +185°F).
Humidity: 5–95% non-condensing
24 binary outputs with enclosed relays (NO contacts)
Current carrying capacity of the relays: max. 1 A
Channel-by-channel isolation of the outputs
Module is capable of redundant operation
Monitoring of the module
Counter for switching cycles (channel by channel)