Motor Control Board
Digital Inputs:24 Vdc
Analog Inputs: 0–10 V / 4–20 mA
Operating Temperature: -10°C to +50°C
Humidity: 5–95% non-condensing
Voltage: 24 Vdc (±10%)
Consumption: ≤ 10 W
Standards: CE, UL, cUL, RoHS
PCB Board
Operating Voltage: 24 Vdc (±10%).
Data Rate: 100 Mbps
Operating Temperature: -40°C to +70°C
Humidity: 5–95% non-condensing
Frequency Converter Board
IGCT MODULE
4500V
91MM
ALT PART NUMBER: 5SHY 3545L0016
DC Bus Voltage: 510–930 V DC
Output Current: Up to 600 A
Operating Temperature: -10°C to +50°C
Humidity: 5–95% non-condensing
SYNCHROTACT 4 multi motor
ABB SYNCHROTACT 4 multi motor
Voltage Inputs: 3-phase AC, 110–690 V
Frequency Range: 45–65 Hz
Frequency Matching: Precision ±0.01 Hz
Voltage Matching: ≤ ±1% deviation
Operating Temperature: -25°C to +55°C
Frequency Converter Power Board
Input Voltage Range: 230 V AC to 690 V AC
Frequency Range: 0–300 Hz
Efficiency: ≥ 98% under standard load conditions
Operating Temperature: -10°C to +55°C
Storage Temperature: -40°C to +70°C
Humidity: 5% to 95% (non-condensing)
ACS880 frequency converter drive board
ACS880 frequency converter drive board
Operating Voltage: 24 Vdc
Analog Inputs: 0–10 V or 4–20 mA
Operating Temperature: -10°C to +50°C
Humidity: 5–95% non-condensing
Compact alternating current drives
Output Power: 160 kW (215 HP) at 400 V AC.
Output Current: 302 A
Input: 380–480 V AC, 3-phase (±10%), 50/60 Hz.
Output: 0–480 V AC
Efficiency: ≥97% (typical at full load)
Control I/O: 5x analog inputs (2x 0–10 V / 0–20 mA)
Switching Frequency: 1–8 kHz
Analog Input Termination Unit
Input Types: Supports 4–20 mA, 0–20 mA, 0–10 VDC
Channels: Typically 8 or 16 channels
Resolution: 16-bit ADC
Supply Voltage: 24 VDC (±10%)
Power Consumption: 2–5 W
Operating Temperature: -20°C to +70°C (-4°F to +158°F)
Storage Temperature: -40°C to +85°C (-40°F to +185°F)
Humidity: 5–95% non-condensing
GATE DRIVE BOARD
Input Voltage: 24 VDC (±10%)
Analog Inputs: 0–10 VDC / 4–20 mA
Fieldbus Support: PROFIBUS DP
Operating Temperature: -25°C to +55°C (-13°F to +131°F).
Humidity: 5–95% non-condensing
PCB CARD
Input Voltage: 24 VDC (±10%)
Analog Inputs: 0–10 VDC / 4–20 mA
Fieldbus Support: PROFIBUS DP
Operating Temperature: -25°C to +55°C (-13°F to +131°F).
Humidity: 5–95% non-condensing.
PCB CARD
Input Voltage: 24 VDC (±10%)
Analog Inputs: 0–10 VDC / 4–20 mA
Fieldbus Support: PROFIBUS DP
Operating Temperature: -25°C to +55°C (-13°F to +131°F).
Humidity: Up to 95% non-condensing
PCB CARD
Input Voltage: 24 VDC (±10%)
Analog Inputs: 0–10 VDC / 4–20 mA
Fieldbus Support: PROFIBUS DP
Operating Temperature: -25°C to +55°C (-13°F to +131°F).
Humidity: Up to 95% non-condensing
Control Card
Input Voltage: 24 VDC (±10%)
Analog Inputs: 0–10 VDC or 4–20 mA
Operating Temperature: -25°C to +55°C (-13°F to +131°F)
Humidity: Up to 95% non-condensing.
Vibration Resistance: 5–150 Hz
Drive board
Input Voltage: 24 VDC (±10%)
Analog Inputs: 0–10 VDC or 4–20 mA
Operating Temperature: -25°C to +55°C (-13°F to +131°F).
Humidity: Up to 95% non-condensing.
Vibration Resistance: 5–150 Hz
PHASE INTERFACE BOARD
RAM: Typically 512 MB to 1 GB
Supply Voltage: 24 VDC (±10%).
Power Consumption: Typically 5–10 W
Operating Temperature: -20°C to +70°C (-4°F to +158°F).
Storage Temperature: -40°C to +85°C (-40°F to +185°F).
Humidity: 5–95% non-condensing
Control board
RAM: Typically 512 MB to 1 GB
Flash Memory: 2–4 GB
Supply Voltage: 24 VDC (±10%).
Power Consumption: Typically 5–10 W
Operating Temperature: -20°C to +70°C (-4°F to +158°F).
Storage Temperature: -40°C to +85°C (-40°F to +185°F).
Humidity: 5–95% non-condensing
PULSE TRANFORMER
Isolation Voltage: Typically 2–4 kV
Primary/Secondary Voltage: 5–24 V AC/DC input
Operating Temperature: -40°C to +85°C
Certifications: Complies with IEC/EN
Turns Ratio: 1:1 or custom ratios
Impedance:50–100 Ω
Binary output module
24 binary outputs with enclosed relays (NO contacts)
Current carrying capacity of the relays: max. 1 A
Channel-by-channel isolation of the outputs
Module is capable of redundant operation
Monitoring of the module
Counter for switching cycles (channel by channel)
Analog output module
16 analog outputs, output signal 0/4 ... 20 mA,
channel-by-channel configuration
Load: max. 700 Ohm
Monitoring of loads
Channel-by-channel isolation of outputs
Module is capable of redundant operation
Digital communication with field devices according to
HART protocol (Version 5.0 / 5.1)
Monitoring of modules
Binary input module
32 binary inputs divided into two groups each with 16 inputs
Process current circuits in accordance
with EN 50020 with type of protection EEx ib IIC
Combined installation possible with
"Non-Ex-modules" in one module sub-rack
Signal recording with 1 ms time resolution
Monitoring of module
Central galvanic separation of system inputs
Group-set filter time
Module is capable of redundancy
Binary input module
32 binary inputs divided into two groups each with 16 inputs
Process current circuits in accordance
with EN 50020 with type of protection EEx ib IIC
Combined installation possible with
"Non-Ex-modules" in one module sub-rack
Signal recording with 1 ms time resolution
Monitoring of module
Central galvanic separation of system inputs
Group-set filter time
Module is capable of redundancy
Coupling Unit
Data Rate: Up to 12 Mbps
Isolation:1500 V AC
Power Supply: 24 V DC (±10%)
Power Consumption: Typically 5–10 W
Fieldbus Port: 9-pin D-sub or M12 for PROFIBUS
Operating Temperature:
-25°C to +70°C (-13°F to +158°F)
Humidity: 5–95% noncondensing
Control panel
Type: LCD or TFT color touchscreen
Operating Voltage: 24 VDC (±10%) or 110–230 VAC
Power Consumption: 10–20 W
Operating Temperature: -10°C to +55°C
Storage Temperature: -40°C to +70°C
Humidity: 5–95% (non-condensing)
FIRING PULSE TRANSFORMER BOARD
Model: SDCS-PIN-H41
Part Number: 3ADT320600R1501
Pulse Voltage: 5–24 V DC
Isolated Pulse Voltage: Typically 10–30 V
Output Current: 1–2 A
Primary-to-Secondary Isolation: ≥2500 V AC
Insulation Resistance: >100 MΩ
Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.