Sensitivity 3.94 mV/mm/s (100 mV/in/s)±5%.
TemperatureSensitivity-8% to +5%
AmplitudeLinearity±2% to 63.5 mm/s pk
MountedResonantFrequency9 kHz, minimum
DynamicOutputImpedance<400 Ω typical
BroadbandNoise Floor 0.229 mm/s (0.009 in/s) pk.
OperatingTemperature-40 °C to +85 °C
StorageTemperature-40 °C to +100 °C
Shock Limit 5000 g pk, maximum.
HumidityLimit100% condensing
3300 XL 8 mm Probe
M10 x 1 thread
with armor
10 1.0 meter (3.3 feet)
01Miniature coaxial ClickLocconnector with connectorprotector,
standard cable
00 Not required
Order in increments of 10 mm
Length configurations:
Maximum unthreaded length: 230 mm
Minimum unthreaded length: 0 mm
Example: 0 6 = 60 mm
7200 5mm / 8mm Series
Proximity Transducer Systems
Frequency Response:
0 Hz (DC) to 10 kHz
Noncontacting
Gap-to-Voltage Transducer Systems
Measures Static and Dynamic Distances
3300 XL 8 mm Probe
3/8-24 UNFthread
with armor
05 0.5 meter (1.6 feet)
02 Miniature coaxial ClickLocconnector,
standard cable
05 CSA, ATEX, IECEx Approvals
Order in increments of 0.1 in.
Length configurations:
Maximum unthreaded length: 8.8 in.
Minimum unthreaded length: 0.0 in.
Example: 0 4 = 0.4 in.
3300 NSv Probe
M8X1 thread
without armor
10 1.0 meter (39 in)
02 Miniature coaxial ClickLoc connector
standard cable
05 Multiple Approvals
Order in increments of 10 mm.
Length configuration:
Maximum unthreaded length:230 mm
Minimum unthreaded length:0 mm
Example:06 = 60 mm
10 0-10 mils pp (0-250 μm pp)
70 7.0 meters (23.0 feet)
01 35 mm DIN rail clips
00 Not required
Operating temperature
-35°C to +85°C(-31°F to +185°F)
Storage temperature
-52°C to +100°C(-62°F to +212°F).
Probe Cable 75Ω coaxial,
fluoroethylenepropylene (FEP) insulated