3300 NSv Proximity Probes
330901 3300 NSv Probe
1/4-28 UNF thread,without armor
Minimum unthreaded length: 0.0 in
Minimum case length: 2.0 in
05 0.5 meter (20 in)
02 Miniature coaxial ClickLoc connector
standard cable
00 Not required
Velomitor Piezo-velocity Sensors
03 1/4 - 28 UNF
01 CSA/US/C
PIEZO VELOCITY SENSOR
100MV/IPS 4MV/MM/S
Interconnect Cable
CABLE EXTENSION 26FEET
Cable Length:26 feet (7.92 meters)
Cable Type:Shielded Foil-Braid Coaxial
Center Conductor: Tinned Copper (20 AWG)
Insulation:High-grade PFAS
Dual-Layer: Aluminum Foil + 85% Braided Copper
Velomitor CT Transducer
Low-Frequency
Measures Casing Vibration Velocity
Compatible with Cooling Towers and
Air-Cooled Heat-Exchanger Fan Assemblies
3300 NSv Proximity Probes
330902 3300 NSv Probe
1/4-28 UNF thread,with armor
Minimum unthreaded length: 0.0 in
Minimum case length:4.0 in
10 1.0 meter (39 in)
02 Miniature coaxial ClickLoc connector
standard cable
00 Not required
3300 NSv Extension Cable
065 6.5 meters (21.3 feet)
05With stainless steel armor
without FEP jacket
withconnector protector
05 Multiple Approvals
3300 XL 8 mm Proximity Probes
330103 3300 XL 8 mm Probe
M10 x 1 thread,without armor
Minimum unthreaded length: 0 mm
Minimum case length: 80 mm
10 1.0 meter (3.3 feet)
02 Miniature coaxial ClickLocconnector
standard cable
05 CSA, ATEX, IECEx Approvals
3300 XL 8 mm Proximity Probes
330103 3300 XL 8 mm Probe
M10 x 1 thread,without armor
Minimum unthreaded length: 0 mm
Minimum case length: 130 mm
10 1.0 meter (3.3 feet)
02 Miniature coaxial ClickLocconnector
standard cable
05 CSA, ATEX, IECEx Approvals
Ingersoll Rand Proximity Probe
3300 NSv · 25" Length
Power Supply:-18 to -24 V DC
Output Signal: -2 to -18 V DC
Sensitivity: 200 mV/mil (7.87 V/mm)
Measurement Range: 0–80 mils (0–2.0 mm)
Frequency Response: 0 to 10 kHz
Probe: -30°C to +150°C (-22°F to +302°F)
Cable: Up to +125°C (°C short-term)
3300 XL Proximitor Sensor
11:1.0 meter (3.3 feet) system length, DINmount
51:5.0 meters (16.4 feet) system length,DIN mount
91:9.0 meters (29.5 feet) system length,DIN mount
00 Not required
Gap Voltage: Standard range -2 V DC to -18 V DC

Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.