0 1 35 mm DIN rail clips
0 0 Not required
ATEXZone 2 and includes ABS maritimeapproval
Power : Requires +12 to +35 Vdc
input at the transmitter terminal.
Maximum Loop Resistance :
1,000 Ω including cable at 35 Vdc.
Current Limiting : 23 mA typical.
3300 XL 8 mm Probe, M10 x 1 thread,without armor
10 1.0 meter (3.3 feet)
02 Miniature coaxial ClickLocconnector, standard cable
05 CSA, ATEX, IECEx Approvals
Order in increments of 10 mm
Metric thread configurations:
Maximum case length: 250 mm
Minimum case length: 20 mm
Example: 0 6 = 60 mm
StandardProbe-52°C to +177°C
ExtendedTemperatureRange Probe-52°C to +218°C
Input voltage range: 88-264 VAC
Output voltage range: 24 VDC
Output current: 10 A
Operating temperature range: -20 to 60°C (-4 to 140°F)
Humidity range: 5 to 95% non-condensing
Vibration: 5g
Shock: 50g