ASKPCB
The board complies with UL 796 standards
Flame rating: V-0,
ensuring good fire resistance
Minimum conductor width: 0.28 mm
Maximum operational temperature: 130°C
Power Requirements 24 VDC
Operating Temperature Range -20°C to 60°C
Humidity Range 5% to 95%
Mounting Options
Standard DIN rail or custom rack mounting
Fully programmable customized menus
LCD color touchscreen, and buttons
Softkeys support different colors and text
Touch pad and touch ring
Ergonomic design with padded wrist rest
Variable-speed joystick with integral zoom control
L ocking power connector
Dedicated keys for commonly used functions
Dynamic menu selection
Web interface for configuration and firmware upgrades
Laser cut backlit keys
Rated Voltage:120/240 VAC or 125 VDC
Input Voltage Range:
85 to 264 VAC or 100 to 300 VDC
Number of Slots:2
Output Power: 40 Watts max
Output Voltage:24 VDC, 5.1 VDC or 3.3 VDC
Output Current:0-1.6 A, 0-6 A, or 0-9 Amps
16 / 32 digital channels
16 channels can be configured as input or output
Configurable interrupt inputs
Status display for each channel via LED
Supply voltage 18 to 34 VDC
Supply voltage protected against reverse polarity
Cost effective and space saving
Head module for CANopen slave stations
Up to 30 I/O modules per slave station
Optional integrated power supply
Transfer rate 10 Kbaud to 1 Mbaud
Bus length to 5000 m (signal repeater required)
Two internally connected CAN interfaces for loop-through of the cable
Galvanic isolation between CAN interfaces and control electronics
Node address can be set via rotary switch
8 analog inputs
8 analog outputs
Connection possibility single-ended or differential
Power supply for up to 4 potentiometers
Temperature inputs for up to 4 Pt100/Pt1000 sensors
2-wire or 4-wire inputs for Pt100/Pt1000 sensors
Wire break detection for the inputs (for voltage and temperature)
Short circuit proof outputs
compact CAN slave module
16/32 channels can be freely configured as input or output
Digital outputs each with 1 A continuous current
Two internally connected CAN interfaces for loop-through of the cable
Galvanic isolation between CAN interfaces and control electronics
Baud rate and node ID can be set via rotary switch
Supply voltage 18 to 34 VDC
Operating range 0 to +60°C without additional cooling
Full wiring without additional backplanes
Up to 5000 mm (typically)
High, typically <1 μm
±0.05% FS (Full Scale)
Analog (0-10V, 4-20mA)
Digital (SSI, CANopen, Profibus, EtherCAT)
-40°C to +85°C
Number of input channels 16 channels,
module isolation (*5)
Rated input range 4 to 20 mA
Permissible input range 0 to 25 mA
Input impedance during Power-OFF 500 kΩ minimum
Data update frequency 40 ms
Temperature drift ±16 µA/10 °C
Withstand voltage 1.5 kV AC between input signal and system for 1 minute
16-channel, module isolation
6 mA ± 20 %
24 V DC +20 % / -10 % (*4), 10 mA or greater
24 V DC +20 % / -10 % (*3) (*4)Current capacity: 200 mA
30.0 V DC
40 ms maximum
2 kV AC between input signal and system for 1 minute, 16-input line collectivelyconnected
16-channel, module isolation
6 mA ± 20 %
24 V DC +20 % / -10 %
10 mA or greater
24 V DC +20 % / -10 %
Current capacity: 200 mA
30.0 V DC
40 ms maximum
2 kV AC between input signal and system for 1 minute
16-input line collectivelyconnected