Fast Scan (Priority I/O Module Scan)
Electronic short circuit protection
Safe-state (FAILOPT) behaviors configurable
on aper channel basis for Digital / Analog Output
HART 7 support (analog IO)
Extended Temperature Range -40 to +70°Cmodule ambient
Primary/Secondary Inputs: Dual 24 V DC (±20% range)
Voltage: 24 V DC (regulated, ±1%)
Per Module: 5 A continuous (10 A peak)
Redundant Capacity: 15 A total
Efficiency: ≥85% (typical load)
Ripple/Noise: <100 mV peak-to-peak
Relay:SPDT, rated 5 A @ 250 V AC
Solid-State Relay (SSR) Driver:12 V DC, 30 mA
Analog Output:0–10 V DC or 4–20 mA
Accuracy: ±0.2% of full scale
Display Type: Backlit LED or LCD
Voltage: 100–240 V AC
Power Consumption: ≤ 5 W
Input Voltage: 24 V DC
Range: 18–32 V DC
Power Consumption: Typically ≤ 10 W
Isolation Voltage: 1500 V AC
Serial Ports: RS-232/RS-485 (configurable).
Ethernet: 10/100 Mbps RJ45 (TCP/IP)
Operating Temperature: -40°C to +70°C (-40°F to +158°F)
Storage Temperature: -50°C to +85°C (-58°F to +185°F)
Extensive internal diagnostics for data integrity
NO Open wire detection
Optional redundancy
On board excitation power
Supplies Non-incendive field power
Direct / Reverse Input Indication
Galvanic isolation
Internal or external field power selection
Function:4 AI: U, I
Number of Analog Configurable I/Os:0
Analog Inputs:4
Input Signal:U, I
Resolution:Analog Input 12 bit
Connection Type:Pluggable
Degree of Protection:Housing IP20
Ambient Air Temperature:
Operation 0 ... +60 °C
Storage -40 ... +70 °C
Output Channels:32
Load Voltage:30 VDC Maximum
Load Current :0.1 A per channel
Galvanic Isolation :1000 VAC RMS for System3
Off-State Voltage:24 V
Off-State Leak Current:100 µA (max)
Turn-On/Turn-Off Time:10 ms (max)
Operating temperature:-5°C-+70°C (+23°F-+158°F)
Storage temperature: -40°C-+85°C (-40°F-+185°F)
Relative humidity: 10-95% (non condensing)
Approvals:CE, TUV, UL, CSA, FM
24 V supply voltage: 24 V DC -15%-+30%
24 V supply current:
< 6 A at 24 Vin (16 A load)
< 7 A at 20.4 Vin (16 A load)
Inrush current: < 5 A at 24 Vin
Hold-up time: < 1ms
Power supply module(24 VDC input)
Standard type with no explosionprotection
Standard type with explosionprotection
Basic type
With ISA Standard G3 option
Input: 200–690 V AC
Output: Matches input voltage
Power Range:0.75 kW to 560 kW
Current Rating:1,300 A
Torque accuracy: ±5% (SLVC mode)
Speed control range: 1:100 (SLVC)
Input: 200–690 V AC
Output: Matches input voltage
Power Range:0.75 kW to 560 kW
Current Rating:1,300 A
Torque accuracy: ±5% (SLVC mode)
Speed control range: 1:100 (SLVC)
Input: 200–690 V AC
Output: Matches input voltage
Power Range:0.75 kW to 560 kW
Current Rating:1,300 A
Torque accuracy: ±5% (SLVC mode)
Speed control range: 1:100 (SLVC)
Voltage: 380–690V AC (±10%), 3-phase
Frequency: 50/60 Hz.
Nominal: 930V DC
Control Circuit Voltage: 24V DC (±15%)
Analog inputs :0–10V, 4–20mA
Temperature: -10°C to +50°C (derate 2% per °C above 40°C)
Humidity: <95% non-condensing
Voltage: 380–690V AC (±10%), 3-phase
Frequency: 50/60 Hz.
Nominal: 930V DC
Control Circuit Voltage: 24V DC (±15%)
Analog inputs :0–10V, 4–20mA
Temperature: -10°C to +50°C (derate 2% per °C above 40°C)
Humidity: <95% non-condensing
With dual-redundant
pressure clamp terminal block for digital input
Rated Voltage:24–60 V DC
Current Rating:≤4 A
Contact Resistance:≤10 mΩ
Isolation Voltage:500 V AC
Operating Temperature:-40°C to +85°C
With dual-redundant
pressure clamp terminal block for digital input
Rated Voltage:24–60 V DC
Current Rating:≤4 A
Contact Resistance:≤10 mΩ
Isolation Voltage:500 V AC
Operating Temperature:-40°C to +85°C
With dual-redundant
pressure clamp terminal block for digital input
Rated Voltage:24–60 V DC
Current Rating:≤4 A
Contact Resistance:≤10 mΩ
Isolation Voltage:500 V AC
Operating Temperature:-40°C to +85°C
With dual-redundant
pressure clamp terminal block for analog
Rated Voltage: 30 V AC
Current Rating:≤4 A
Contact Resistance:≤10 mΩ
Isolation Voltage:300 V AC
Terminal Material :Tin-plated copper alloy
Operating Temperature:-40°C to +85°C