


























PowerFlex 753 AC Drive
Bulletin Number:PowerFlex 753 AC Drive, with Embedded I/O
Corrosive Gas Protection and Cooling Type:
Standard Protection, Forced Air
Voltage Class:480 VAC, 3 PH
Output Current:14 Amps, 10HP ND, 7.5HP HD
Enclosure Type:Open Type
Input Type:AC Input with DC Terminals
Frame Size:Frame 2
EMC Filtering Options:Filtered,
CM jumper installed (preferred)
Dynamic Braking:DB Transistor
PanelView 800 Graphic Terminals
Operator Input:Touch /Keypad
Backlight:40,000 hours
Resolution:480 x 272
Integrated Memory: 256 MB Flash Memory; 256 MB DDR RAM
Input Voltage range:18-32VDC
Part Number/Catalog No.:2711R-T4T
Product Line:Panelview 800
Display Color:Color TFT
Input Type:Analog touch and function keys
POINT I/O module
Power Dissipation:2.0 Watt/6.8 BTU/hour
POINTBus Current:75 mA
Output Voltage:24 Volts DC
Module Type:Digital DC Sourcing Output
Series:POINT I/O
Part Number/Catalog No.:1734-OB8
No. of outputs:8; Sourcing output
Output Voltage range:10-28.8VDC
Analog Input Module
Series:ControlLogix
Module Type:Hart Isolated Analog Input Module
Channels:8 Isolated Differential
Input Range:0-20 or 4-20 milliamps
Resolution:16-21 bits
Enclosure:Open
Overvoltage Protection:(+/-) 24 Volts
Analog Input Module
Module Type:Analog Input Module
Inputs:16 single, 8 differential, 4 highspeed differential
Input Resolution:(+--)10.25 Volts, 0-5.125 Volts, 0-10.25 Volts
Backplane Current (5Volts):150 milliamps
Backplane Current (24Volts):65 milliamps
Power Dissipation (Max):2.3 Watts (Voltage), 3.9 Watts (Current)
Removeable Terminal Blocks:1756-TBCH, 1756-TBS6H
ControlLogix Hydraulic Servo Module
Gain Resolution:32- bit floating point
Absolute Position range:230,000 LDT counts
Rate:500Hz to 4kHz (Selectable)
LDT Input:PWM, Start/Stop rising or falling edge
Registration input:Optically isolated, current sinking input
Analog output:±10V dc
Analog output resolution:16 bits
Discrete outputs:Solid-state isolated relay contacts
Discrete output operating voltage:24VDC, Nominal.
PowerFlex 753 AC Drive
Bulletin Number:PowerFlex 753 AC Drive
with Embedded I/O
Corrosive Gas Protection and Cooling Type:
Standard Protection, Forced Air
Voltage Class:480 VAC, 3 PH
Output Current:11 Amps,
(Fr1 7.5HP ND, 5HP HD/Fr2 7.5HP ND, 7.5HP HD)
Enclosure Type:Open Type
Input Type:AC Input with DC Terminals
Frame Size:Frame 2
EMC Filtering Options:Filtered, CM jumper installed (preferred)
Dynamic Braking:DB Transistor
PowerFlex 753 AC Drive
Bulletin Number:PowerFlex 753 AC Drive
with Embedded I/O
Corrosive Gas Protection and Cooling Type:
Standard Protection, Forced Air
Voltage Class:400 VAC, 3 PH
Output Current:5 Amps,
(Fr1 2.2kW ND, 1.5kW HD/Fr2 2.2kW ND, 2.2kW HD)
Enclosure Type:Open Type
Input Type:AC Input with DC Terminals
Frame Size:Frame 2
EMC Filtering Options:Filtered, CM jumper installed (preferred)
Dynamic Braking:DB Transistor
HIM Blank (No HIM)
PowerFlex 753 AC Drive
Bulletin Number:PowerFlex 753 AC Drive
with Embedded I/O
Corrosive Gas Protection and Cooling Type:
Standard Protection, Forced Air
Voltage Class:400 VAC, 3 PH
Output Current:3.5 Amps,
(Fr1 1.5kW ND, 0.75kW HD/Fr2 1.5kW ND, 0.1.5kW HD)
Enclosure Type:Open Type
Input Type:AC Input with DC Terminals
Frame Size:Frame 2
EMC Filtering Options:Filtered, CM jumper installed (preferred)
Dynamic Braking:DB Transistor
HIM Blank (No HIM)
PowerFlex 753 AC Drive
Bulletin Number:PowerFlex 753 AC Drive
with Embedded I/O
Corrosive Gas Protection and Cooling Type:
Standard Protection, Forced Air
Voltage Class:400 VAC, 3 PH
Output Current:2.1 Amps,
(Fr1 0.75kW ND, 0.37kW HD/Fr2 0.75kW ND, 0.75kW HD)"
Enclosure Type:Open Type
Input Type:AC Input with DC Terminals
Frame Size:Frame 2
EMC Filtering Options:Filtered, CM jumper installed (preferred)
Dynamic Braking:DB Transistor
HIM Blank (No HIM)
PowerFlex 753 AC Drive
Bulletin Number:PowerFlex 753 AC Drive
with Embedded I/O
Corrosive Gas Protection and Cooling Type:
Standard Protection, Forced Air
Voltage Class:400 VAC, 3 PH
Output Current:104 Amps, 55kW ND, 45kW HD
Enclosure Type:Open Type
Input Type:AC Input with DC Terminals
Frame Size:Frame 5
EMC Filtering Options:Filtered, CM jumper installed (preferred)
Dynamic Braking:DB Transistor
HIM Blank (No HIM)
PowerFlex 753 AC Drive
Bulletin Number:PowerFlex 753 AC Drive,
with Embedded I/O
Corrosive Gas Protection and Cooling Type:
Standard Protection, Forced Air
Voltage Class:400 VAC, 3 PH
Output Current:85 Amps, 45kW ND, 37kW HD
Enclosure Type:Open Type
Input Type:AC Input with DC Terminals
Frame Size:Frame 5
EMC Filtering Options:Filtered, CM jumper installed (preferred)
Dynamic Braking:DB Transistor
PowerFlex 753 AC Drive
PowerFlex 753 AC Drive
with Embedded I/O, Standard Protection
Forced Air, AC Input with DC Terminals
Open Type, 72 Amps, 37kW ND
30kW HD, 400 VAC, 3 PH, Frame 4
Filtered, CM jumper installed (preferred)
DB Transistor, Blank (No HIM)
PowerFlex 753 AC Drive
PowerFlex 753 AC Drive
with Embedded I/O, Standard Protection
Forced Air, AC Input with DC Terminals
Open Type, 60 Amps, 30kW ND
22kW HD, 400 VAC, 3 PH, Frame 4
Filtered, CM jumper installed (preferred)
DB Transistor, Blank (No HIM)
Input Power Controller
Manufacturer:Rockwell Automation
Brand:Allen-Bradley
Part Number/Catalog No.:1762-L24BWAR
Input Power:120-240V AC
Inputs:(10) 24V DC and (4) Fast 24V DC
Outputs:(10) Relay
Redundant H1 Terminal Block
I/O Count 20 points
Input Type:120V ac
Analog Circuits:4 Inputs, 1 Output
Protocol:DF1
Safety Feature:Master Control Relay
Digital Outputs:8 Contact Outputs
No. of Discrete Inputs:Twelve (12)
Input Voltage Type:120 Volts AC
Voltage Range:79-132 Volts AC
Output Type:Eight (8) Relay
PowerFlex 753 AC drive
Series:PowerFlex 753
Frames:1..5, 8...10
Enclosure Type:AC and DC Input with Precharge
Frames:2 2...7
Enclosure Type 2:IP20/IP00, NEMA/UL Type Open
Voltage:400 Volts AC/540 Volts DC
Horsepower:300
Filtering:Yes
Default CM Cap Connection:Jumper Installed
Frequency drive
PowerFlex 753 AC Drive
with Embedded I/O, Standard Protection
Forced Air, AC Input with DC Terminals
Open Type, 37 Amps, 18.5kW ND
15kW HD, 400 VAC, 3 PH, Frame 3
Filtered, CM jumper installed (preferred)
DB Transistor, Blank (No HIM)
Frequency drive
PowerFlex 753 AC Drive
with Embedded I/O, Standard Protection
Forced Air, AC Input with DC Terminals
Open Type, 30 Amps, 15kW ND, 11kW HD
400 VAC, 3 PH, Frame 3, Filtered
CM jumper installed (preferred)
DB Transistor, Blank (No HIM)
Frequency drive
Part Number/Catalog No.:20F11NC015JA0NNNNN
Series:PowerFlex 753
Frames:1..5,8...10
Enclosure Type:AC & DC Input w/Precharge
Frames:2 2...7
Enclosure Type 2:IP20/IP00, NEMA/UL Type Open
Voltage:400V AC/540V DC
Filtering:Yes
Default CM Cap Connection:Jumper Installed
Frequency AC drive
Series:PowerFlex 753
Frames:1..5, 8...10
Enclosure Type:AC & DC Input w/Precharge
Frames:2 2...5
Enclosure Type 2:Flange (NEMA/UL Type 4X/12 back)
Voltage:400V AC/540V DC
Filtering:Yes
Frequency AC drive
PowerFlex 753 AC Drive
with Embedded I/O
Standard Protection
Forced Air, AC Input with DC Terminals
Type 12 / IP54, 43 Amps, 22kW ND
18.5kW HD, 400 VAC, 3 PH, Frame 3, Filtered
CM jumper installed (preferred)
DB Transistor, Blank (No HIM)
Frequency AC drive
Series:PowerFlex 753
Frames:1..5,8...10
Enclosure Type:AC & DC Input w/Precharge
Frames:2 2...7
Enclosure Type 2:IP54, NEMA/UL Type 12
Voltage:400V AC/540V DC
Filtering:Yes
Default CM Cap Connection:Jumper Installed
AC frequency converter
PowerFlex 753 AC Drive
with Embedded I/O
Standard Protection
Forced Air, AC Input with DC Terminals
Type 12 / IP54, 11.5 Amps
(Fr1 5.5kW ND, 4kW HD/Fr2 5.5kW ND, 5.5kW HD)
400 VAC, 3 PH, Frame 2, Filtered
CM jumper installed (preferred)
DB Transistor, Blank (No HIM)
AC frequency converter
PowerFlex 753 AC Drive
with Embedded I/O
Standard Protection
Forced Air, AC Input with DC Terminals
Flange Type, 104 Amps, 55kW ND
45kW HD, 400 VAC, 3 PH, Frame 5
Filtered, CM jumper installed (preferred)
DB Transistor, Blank (No HIM)

Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.