3300 XL 8 mm Probe
M10 x 1 thread
without armor
50 5.0 meters (16.4 feet)
02 Miniature coaxial ClickLocconnector, standard cable
00 Not required
Order in increments of 10 mm
Metric thread configurations:
Maximum case length: 250 mm
Minimum case length: 20 mm
Example: 0 6 = 60 mm
330101 3300 XL 8 mm Probe
3/8-24 UNFthread, without armor
Minimum unthreaded length: 0.0 in
Minimum case length: 1.5 in
15 1.5 meter (4.9 feet)
01Miniature coaxial ClickLocconnector
with connectorprotector, standard cable
00 Not required
330104 3300 XL 8 mm Probe
M10 x 1 thread,with armor
Minimum unthreaded length: 0 mm
Minimum case length: 140 mm
10 1.0 meter (3.3 feet)
02 Miniature coaxial ClickLocconnector
standard cable
330104 3300 XL 8 mm Probe
M10 x 1 thread,with armor
Minimum unthreaded length: 0 mm
Minimum case length: 50 mm
10 1.0 meter (3.3 feet)
11Miniature coaxial ClickLocconnector
with connectorprotector, FluidLoc cable
00 Not required
330102 3300 XL 8 mm Probe
3/8-24 UNFthread, with armor
Minimum unthreaded length: 0.0 in
Minimum case length: 2.5 in
50 5.0 meters (16.4 feet)
11Miniature coaxial ClickLocconnector
with connectorprotector, FluidLoc cable
00 Not required
330101 3300 XL 8 mm Probe
3/8-24 UNFthread, without armor
Minimum unthreaded length:2.0 in
Minimum case length: 3.9 in
10 1.0 meter (3.3 feet)
02 Miniature coaxial ClickLocconnector
standard cable
05 CSA, ATEX, IECEx Approvals
Standard Range: 0 to 500 mils
Extended Range Options: Up to 1000 mils (25.4 mm)
Sensitivity: 200 mV/mil
Phase Delay: < 1° at 1 kHz
Voltage Output: –2 V to –18 V DC
Current Output (Optional): 4–20 mA
Standard: 0–500 mils
Sensitivity:200 mV/mil
Extended Options: Up to 1,000 mils
Voltage: –2 V to –18 V DC
Current (Optional): 4–20 mA
Linearity:±1% of full scale
Power Supply:–18 to –24 V DC