330703 3300 XL 11 mm Probe
M14 x 1.5 thread,without armor
Minimum length:80 mm
10 1.0 meter (3.3 feet)
02 Miniature coaxial ClickLocconnector
standard cable
00 Not required
330104 3300 XL 8 mm Probe
M10 x 1 thread,with armor
Minimum case length: 40 mm
10 1.0 meter (3.3 feet)
02 Miniature coaxial ClickLocconnector
standard cable
00 Not required
330704 3300 XL 11 mm Probe
M14 x 1.5 thread,with armor
Minimum unthreaded length:0 mm
Minimum length: 50 mm
10 1.0 meter (3.3 feet)
02 Miniature coaxial ClickLocconnector
standard cable
00 Not required
330101 3300 XL 8 mm Probe
3/8-24 UNFthread, without armor
Minimum unthreaded length:0.0 in
Minimum case length: 0.8 in
10 1.0 meter (3.3 feet)
02 Miniature coaxial ClickLocconnector
standard cable
00 Not required
0 2 M8 X 1 integral stud
0 5Multiple approvals (CSA, ATEX, IECEx,)
Sensitivity 10.2 mV/m/s2 (100 mV/g) ±5%.
AmplitudeLinearity±1% to 490 m/ s2 (50 g) peak
FrequencyResponse10 Hz to 15 kHz
TransverseSensitivity Less than 5% of axial.
Amplitude ofResonantPeak20 dB maximum
MountedResonantFrequencyGreater than 30 kHz
本特利TK3-2E 14700-02ATK32E
DISCONTINUED BY MANUFACTURER
WOBULATOR
CALIBRATION INSTRUMENT
1AMP
190-250VAC MAX
50/60HZ
90PSI MAX/6.2BAR
STIMULATES SHAFT VIBRATION AND POSITION
FOR CALIBRATING BENTLY NEVADA MONITORS
(14700-01)
Immediate Recovery from Power Loss
High Resolution Static, Orbit, and Spectrum Data
Ethernet Link to Data Manager
Two Independent Startup/Shutdown Buffers
0 5 0-5 mils pp (0-125 μm pp)
7 0 7.0 metres (23.0 feet)
0 1 35 mm DIN rail clips
0 1 CSA Division 2
Power : Requires +12 to +35 Vdc
input at the transmitter terminal.
Maximum Loop Resistance :
1,000 Ω including cable at 35 Vdc.
Current Limiting : 23 mA typical