Cabinet infrastructure with SP, fanless
Model Number:51454416-600
Type:Active-Cooled Cabinet Infrastructure
Input Voltage:100-240V AC (auto-ranging, 50/60Hz)
Power Supply:400W (94% efficiency, 80 Plus Platinum)
Output Rails:+3.3V, +5V, +12V, +24V, -12V
Power Distribution:12 slots with individual circuit breakers
Surge Protection:±6kV line-to-line, ±8kV line-to-ground
Cabinet infrastructure with SP, fan
Model Number:51454416-500
Type:Active-Cooled Cabinet Infrastructure
Input Voltage:100-240V AC (auto-ranging, 50/60Hz)
Power Supply:400W (94% efficiency, 80 Plus Platinum)
Output Rails:+3.3V, +5V, +12V, +24V, -12V
Power Distribution:12 slots with individual circuit breakers
Surge Protection:±6kV line-to-line, ±8kV line-to-ground
Cabinet infrastructure with base, SP, fanless
Model Number:51454416-200
Type:Fanless Cabinet Infrastructure
Input Voltage:100-240V AC (50/60Hz) or 24V DC
Power Supply:200W integrated (90% efficiency)
Output Rails: +5V, +12V, +24V (fully regulated)
Power Distribution:8 slots with individual protection
Surge Protection:±4kV line-to-line, ±6kV line-to-ground
ETHERNET INTERFACE MODULE
Input Voltage:24V DC (18-36V)
Power Consumption:4.8W (typical), 6.5W (max)
Port Configuration:2x 10/100/1000BASE-T
Isolation :1500V AC
Surge Protection:±2kV
Data Rate:10/100/1000 Mbps
Latency:<5μs
Jitter:<500ns
MAC Address Table:2048 entries
RAM Charger Module
Optional C300 Memory Backup
Series 8 C300 RAM Charger Module
Support up to 4 C300 controllers in one module
Supports redundant power supply inputs through combo cable
Supports Experion soft failure alarm for RAM charger battery status
Typically mounted adjacent to its associated C300 IOTA(s)
Digital Output Module
Output Channels:32
Output Type:Source
Voltage Rating:24 VDC
Module current rating:105mA
Load Voltage:30 VDC Maximum
On-State Voltage:24 VDC (typ)
Off-State Leak Current:5 µA (max)
Profibus Gateway Module
Detailed Specifications
Modules
and Capacities
Profibus Gateway Module
PROFIBUS Gateway ASSY, Coated
Series 8 Header Board
Redundant power distribution
IOLink communication system
Ability to extend power cabinets through connectors
Four connectors for combination power
IOLink cable to IO modules in cabinet
Analog Input Module
AI IOTA
Extensive self-diagnostics
Optional redundancy
Supports either Single Ended / DifferentialInputs
HART-capable, multivariable instruments
and multiplemodems for fast collection of control variables
Fast loop scan
Roller Lever Limit Switch
Honeywell LS Series
Roller Lever Limit Switch
1NC/1NO, IP67, SPDT
Die Cast Zinc Housing
480V ac ac Max
10A Ma
Analog Output Module
Analog Output w/o HART
Extensive self-diagnostics
Optional redundancy
Safe-state (FAILOPT)
behaviors configurable ona per channel basis
Analog Output Module
Analog Output (AO) Module
Extensive self diagnostics
Optional redundancy
Series 8 AO module supports
Low Level Analog (Temperature) Input
Low-level AI IOTA
TC and RTD operation
Remote Cold Junction compensation capability
Second PV scanning with OTD protection
Configurable OTD protection (See below)
Temperature points can be added in 16 pointincrements
S8 C300 CONTROLLER IOTA, BLK, COATED
8CTCNTA1
DISCONTINUED BY MANUFACTURER
I/O CONTROLLER
TERMINATION ASSEMBLEY
COATED
SERIES 8
C300
Analog Output Module
Series 8 AO module
Analog Output (AO) Module
Extensive self diagnostics
Optional redundancy
HART-capable, multivariable devices
S8 AI HART IOM (16), COATED
High-level AI HART, Single-ended
Extensive self-diagnostics
Optional redundancy
HART-capable, multivariable devices
Fast loop scan
Internal or external field power selection
Suitable for Configure / Status for HART Device
Galvanic Isolation
Analog Output Module
Analog Output (AO) Module
Extensive self diagnostics
Optional redundancy
Series 8 AO module supports
S8 HLAI IOTA (16), RED, BLK, COATED
Extensive self diagnostics
Optional redundancy
Fast loop scan
Internal or external field power selection
On board excitation power
(no need for marshalling power)
Galvanic Isolation
Analog Input Module
Extensive self diagnostics
Optional redundancy
Fast loop scan
Internal or external field power selection
On board excitation power
Galvanic Isolation
Analog Input Module
IOTA Module
Extensive self-diagnostics
Optional redundancy
HART-capable, multivariable devices
Fast loop scan
Internal or external field power selection
Suitable for Configure / Status for HART Device
Galvanic Isolation
Analog Input Module
AI IOTA Redundant
Extensive self-diagnostics
Optional redundancy
Supports either Single Ended / DifferentialInputs
HART-capable, multivariable instruments
and multiplemodems for fast collection of control variables
Fast loop scan
Low Level Analog (Temperature) Input
Low-level AI – RTD & TC
TC and RTD operation
Remote Cold Junction compensation capability
Second PV scanning with OTD protection
Configurable OTD protection (See below)
Temperature points can be added in 16 pointincrements

Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.