Kindly Reminder
Can't Find Your Required Components?
If your specific control system parts are not listed on our website, contact us immediately.
Our procurement specialists will source genuine new components tailored to your technical requirements.
All Amikon-supplied automation parts include:
12 Months Warranty
24h /7 online Service ( info@amikon.cn | +86 18020776786 )
Original new Factory Sealed
Analog Output Module
ANALOG OUTPUT MODULE
16 INPUT CHANNELS
COMPRESSION TERMINALS
ML-TAOY22
INPUT MODULE
INPUT MODULE
PULSE
CLASS I / DIVISION 2
8 POINT / ISOLATION
.004 AMP @ 1.2 VDC
0.5 AMP @ 5.1 VDC
.002 AMP @ 24 VDC
Redundant Expansion Driver
Redundant Expansion Driver
Redundant Expansion Driver, TP/FO
Input Voltage:24V DC (18-36V range)
Power Consumption:22W (operational), 30W (max)
Isolation:2500V AC
Digital Inputs:12 channels
Analog Outputs:4 channels
Drive Outputs:6 channels
Profibus‑DP master module
Protocol: Profibus-DP
Data Transfer Rate: 9.6 kbps to 12 Mbps
Max. Number of Slaves: Up to 125 devices
Cable Length:Up to 1200 m
Connector Type: 9-pin D-sub
Bus Voltage: 5V logic
Panel Mount Operator Advisor Panel (OPADP)
51305776100
INTERFACE MODULE ASSEMBLY
ADAPTER UNIT
OEP/IKB
Digital Input 24V IOTA Redundant
Galvanic isolation
Open wire detectio
Optional redundancy
Direct / Reverse Input Indication
Supplies Non-incendive field power
Internal or external field power selection
Extensive internal diagnostics for data integrity
HART Analog Output Module
Input Voltage:100–240 VAC (universal)
Output Voltage:24 VDC (adjustable up to ~27 V)
Output Current:20 A continuous
Protections:Overcurrent, overvoltage, short-circuit
Operating Temperature Range:–25 °C to +70 °C
Digital I/O module
Channels:Typically 16 I/O
Output Types:Digital(0–10 VDC, 4–20 mA)
Analog Resolution:AI: 16‑bit; AO: 13‑bit
Power Supply:24 V DC nominal
Power Isolation:Galvanic isolation, reverse protection
Operating Temp:–40 °C to +70 °C
Enclosure / Rating:Up to IP66
I/O Module
Channels:Typically 16 I/O
Output Types:Analog (0–10 VDC, 4–20 mA)
Analog Resolution:AI: 16‑bit; AO: 13‑bit
Power Supply:24 V DC nominal
Power Isolation:Galvanic isolation, reverse protection
Operating Temp:–40 °C to +70 °C
Enclosure / Rating:Up to IP66
Multi-Mode Fiber Optic Module
Medium: Multimode Dielectric Fiber 62.5/125
Wavelength:1300 nm
Maximum:Distance 2 km (1 mile)
Connector:MT-RJ
Voltage:3.3 V
Temperature Industrial:-40 C to +85 C (-40 F to +185 F)
Battery and Key Switch Module
Product Type : Battery and Key Switch Module
Relative humidity: 10—95% (non condensing)
Approvals: CE, TUV, UL, CSA, FM
24 V supply voltage: 24 Vdc –15%—+30%
24 V supply current: max. 20 mA
5 VR supply voltage: 5 Vdc ± 10%
5 VR supply current: max. 10 mA
Output supply voltage: 14—31 Vdc
Output resistance: approx. 2 × 1.1 kΩ (parallel)
Safety Manager System Module
Supply voltage: 24 V DC
Reset input voltage: 18 - 70 V DC
Reset input current: 1.1 mA at 24 V DC
Earth fault threshold: 5.5 mA (± 1 mA)
Max. earth current: 25 - 32 mA
Max. output current: 2 A
Isolation 1500 V DC / 1000 V AC
Initial contact resistance: 30 mW
Operating temperature: -5°C-+50°C (23°F-+122°F)
Max. output voltage: 36 V DC / 30 V AC
Interconnection Cable
Direct connection between two
FS-CP series process controllers
10 meters long
Shielded twisted pair design
Easy to install and use
Hot-pluggable
Universal Input Output Module
Fast Scan (Priority I/O Module Scan)
Electronic short circuit protection
Safe-state (FAILOPT) behaviors configurable
on aper channel basis for Digital / Analog Output
HART 7 support (analog IO)
Extended Temperature Range -40 to +70°Cmodule ambient
Redundant Power Supply
Primary/Secondary Inputs: Dual 24 V DC (±20% range)
Voltage: 24 V DC (regulated, ±1%)
Per Module: 5 A continuous (10 A peak)
Redundant Capacity: 15 A total
Efficiency: ≥85% (typical load)
Ripple/Noise: <100 mV peak-to-peak
TEMP CONTROLLER
Relay:SPDT, rated 5 A @ 250 V AC
Solid-State Relay (SSR) Driver:12 V DC, 30 mA
Analog Output:0–10 V DC or 4–20 mA
Accuracy: ±0.2% of full scale
Display Type: Backlit LED or LCD
Voltage: 100–240 V AC
Power Consumption: ≤ 5 W
Digital Input Module
Extensive internal diagnostics for data integrity
NO Open wire detection
Optional redundancy
On board excitation power
Supplies Non-incendive field power
Direct / Reverse Input Indication
Galvanic isolation
Internal or external field power selection
Hpm I/o Link Pc Board
I/O Type:Digital or analog I/O
Voltage Range:24 VDC (±10%)
Isolation:1500 VAC typical
Environmental Rating:Operates in -40°C to +70°C
Analog Input Module
Input Type Current (2-wire or self-powered transmitters)
Input Channels 16 Channels (16 Single Ended)
Common Mode Rejection Ratio, dc to 60 Hz 70 dB
A/D Converter Resolution 16 bits
Input Range 4-20 mA (through 200 Ω)
Normal Mode Rejection Ratio, at 60 Hz 20 dB
Normal Mode Filter Response Single-pole RC, -3 dB @ 6.0 Hz
Maximum Normal Mode Input ± 30 Volts
Hlai/sti galvanic isolator module
Description : HLAI/STI FTA, GI/IS MC-GAIH13
CE compliant, conformally coated
Redundancy
Channels : 16
Galvanically Isolated
Terminals : Compression
Size B : 12 inches (307 mm)
PROBE LOW TEMP 20FT PH
Measuring Range: 0–14 pH.
Process Fluid: 0°C to 50°C (32°F to 122°F)
Response Time: ≤30 seconds
Cable: 20 feet shielded, UV-resistant
Pressure Rating: ≤5 bar (72.5 psi)
Calibration: 2–3 point calibration
Universal Input Output IOTA
Electronic short circuit protection1
Fast Scan (Priority I/O Module Scan)
Safe-state (FAILOPT) behaviors configurable
on aper channel basis for Digital / Analog Output
HART 7 support (Analog I/O)
HART Modem per Channel for Fast Performance
Extended Temperature Range -40 to +70°Cmodule ambient
Universal Input Output IOTA Red
Electronic short circuit protection1
Fast Scan (Priority I/O Module Scan)
Safe-state (FAILOPT) behaviors configurable
on aper channel basis for Digital / Analog Output
HART 7 support (Analog I/O)
HART Modem per Channel for Fast Performance
Extended Temperature Range -40 to +70°Cmodule ambient

Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.