PROBE LOW TEMP 20FT PH
Measuring Range: 0–14 pH.
Process Fluid: 0°C to 50°C (32°F to 122°F)
Response Time: ≤30 seconds
Cable: 20 feet shielded, UV-resistant
Pressure Rating: ≤5 bar (72.5 psi)
Calibration: 2–3 point calibration
Universal Input Output IOTA
Electronic short circuit protection1
Fast Scan (Priority I/O Module Scan)
Safe-state (FAILOPT) behaviors configurable
on aper channel basis for Digital / Analog Output
HART 7 support (Analog I/O)
HART Modem per Channel for Fast Performance
Extended Temperature Range -40 to +70°Cmodule ambient
Universal Input Output IOTA Red
DISOE - Sequence of Events
Open Wire Detection
Electronic short circuit protection
HART Modem per Channel for Fast Performance
Digital Output Module
DC-TDOD51
Digital Output Module
Optional redundancy
Electronic Overcurrent protection
IOL FOE PM VIOLET - 0.5M
Cable Type: Fiber Optic Ethernet.
Connector Type: IOL (Input/Output Link) connectors.
Length: 0.5 meters
Operating Voltage: 24 VDC.
Operating Current: 0.5 A.
Maximum Power Consumption: 12 W
Digital Output IOTA Redundant
Extensive internal diagnostics to ensure dataintegrity
Optional redundancy
Electronic Overcurrent protection
Configurable Safe-state (FAILOPT)
Latched, pulsed or pulse-width modulated output
Digital Input IOTA Redundant
Extensive internal diagnostics for data integrity
NO Open wire detection
Optional redundancy
Internal or external field power selection
Supplies Non-incendive field power
Direct / Reverse Input Indication
Galvanic isolation
Analog Output IOTA Redundant
Extensive self-diagnostics
Optional redundancy
Supplies non-incendive field power
Open-wire Bad PV Detection
Non-incendive Power
ANALOG OUTPUT MODULE
CCSDRX01
I/O LINK INTERFACE
FIBER OPTIC CONVERTER
9 PORTS
ANALOG OUTPUT MODULE
ACCELEROMETER
Acceleration Range: ±2g, ±5g, ±10g, or ±50g
Voltage output, typically 0-5V or 0-10V
Supply Voltage: 5V DC or 12V DC
Operating Temperature: -40°C to +85°C
Safety Manager SC Hardware
Input Channels 16 or more digital inputs,
Output Channels 16 or more digital outputs
Operating Voltage 24 VDC (nominal)
Power Consumption Typically <20 W
Operating Temperature -10°C to +60°C
Storage Temperature -40°C to +85°C
Mounting Type DIN rail or panel mount
Communication Protocols Modbus TCP, Profibus,
EtherCAT, CANopen, and other industrial protocols
SC IOTA PDIO Redundant Module
Operating Voltage 24 VDC
Power Consumption Typically <20 W
Communication Protocols Modbus TCP,
Profibus, EtherCAT, CANopen,
and other standard industrial protocols
Operating Temperature -10°C to +60°C
Storage Temperature -40°C to +85°C
SC S300 IOTA CONTROLLER REDUNDANT
Safety Standard Compliance
IEC 61508 SIL3, ISO 13849-1
and other relevant safety standards
Input Channels Configurable digital and analog inputs
Output Channels Digital and relay outputs
tailored for controlling safety-critical systems
Communication Protocols
Modbus TCP, Profibus,
EtherCAT, CANopen, and
other standard industrial protocols
Earth Fault Monitor
Temperature -40°C to +75°C
(-40°F to +167°F )
Approvals CE, TUV
DIN EN rails: TS32 / TS35 x 7.5
Input voltage:24 VDC +30/-15%
Input current:10 mA maximum 25 mA
Voltage typically +4.1 VDC
Resistor (R)approximately 2.8 kOhm
PWA / I/O LINK MODULE
Module Type I/O Link Module
Power Supply 24 VDC
Operating Temperature -20°C to +60°C
Storage Temperature -40°C to +85°C
Humidity 5% to 95% non-condensing
Interface Board
TDC3000
TDC3000 framework
5 VDC
Approx. 1.5 W
300 mA (nominal)
TDC-specific protocols for
data transfer and communication
WSI2 Unix coprocessor card
100 MHz
without graphics
used in the UxS and AxM.
with 32, 64, or 128 MB of RAM memory
Interface Converter Board
24V DC internal power supply
within the system
-20 ° C to 70 ° C
5% to 95%, no condensation
Multiple digital/analog input/output interfaces
DIN rail installation or rack mounted installation
RACK 10 SLOT
TKFXX102
RACK 10SLOT COATED
5.1VDC - 15/6AMP
24VDC - 2.8/2.8AMP
3.3VDC - 4/4AMP
Power Supply
51198947100
DISCONTINUED BY MANUFACTURER
POWER SUPPLY
115/240 VAC INPUT
50/60 HZ
25 VDC OUTPUT
10 AMP LOAD
550 WATT POWER
CONTROL BOARD
51401551301
CONTROL BOARD
K2LCN-3
MULTI INPUT/OUTPUT
PANEL MOUNT
SINGLE SLOT
Digital Output Module
Optional redundancy
Electronic Overcurrent protection
Configurable Safe-state (FAILOPT)
Extensive internal diagnostics to ensure data integrity
Latched, pulsed or pulse-width modulated output(per channel)

Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.