Analog Input Module
Input Type Current (2-wire or self-powered transmitters)
Input Channels 16 Channels (16 Single Ended)
Common Mode Rejection Ratio, dc to 60 Hz 70 dB
A/D Converter Resolution 16 bits
Input Range 4-20 mA (through 200 Ω)
Normal Mode Rejection Ratio, at 60 Hz 20 dB
Normal Mode Filter Response Single-pole RC, -3 dB @ 6.0 Hz
Maximum Normal Mode Input ± 30 Volts
Hlai/sti galvanic isolator module
Description : HLAI/STI FTA, GI/IS MC-GAIH13
CE compliant, conformally coated
Redundancy
Channels : 16
Galvanically Isolated
Terminals : Compression
Size B : 12 inches (307 mm)
PROBE LOW TEMP 20FT PH
Measuring Range: 0–14 pH.
Process Fluid: 0°C to 50°C (32°F to 122°F)
Response Time: ≤30 seconds
Cable: 20 feet shielded, UV-resistant
Pressure Rating: ≤5 bar (72.5 psi)
Calibration: 2–3 point calibration
Analog Input Module
ANALOG INPUT MODULE
24VDC
16 CHANNEL
Absolute accuracy
Correct conversion over the full range
Crosstalk between inputs
Channel input filters
Internal supply voltages
Universal Input Output IOTA
Electronic short circuit protection1
Fast Scan (Priority I/O Module Scan)
Safe-state (FAILOPT) behaviors configurable
on aper channel basis for Digital / Analog Output
HART 7 support (Analog I/O)
HART Modem per Channel for Fast Performance
Extended Temperature Range -40 to +70°Cmodule ambient
Universal Input Output IOTA Red
DISOE - Sequence of Events
Open Wire Detection
Electronic short circuit protection
HART Modem per Channel for Fast Performance
Digital Output Module
DC-TDOD51
Digital Output Module
Optional redundancy
Electronic Overcurrent protection
Revision C IO Link Cable
Type: IO Link Cable
Part Number: 51202341-102 Revision C
Country of Origin: USA
Cable Length: 1 meter
Shielding: Shielded
HORIZONTAL BACK PLANE PWA
Operating Voltage: 24 V DC
Input Current: 1 A
Output Power: 20 W
Bus Interface: RS-485
Operating Temperature: -20°C to +70°C
Humidity Range: 5% to 95% non-condensing
Certifications: CE, UL, ISO 9001
IOL FOE PM VIOLET - 0.5M
Cable Type: Fiber Optic Ethernet.
Connector Type: IOL (Input/Output Link) connectors.
Length: 0.5 meters
Operating Voltage: 24 VDC.
Operating Current: 0.5 A.
Maximum Power Consumption: 12 W
Digital Output IOTA Redundant
Extensive internal diagnostics to ensure dataintegrity
Optional redundancy
Electronic Overcurrent protection
Configurable Safe-state (FAILOPT)
Latched, pulsed or pulse-width modulated output
Digital Input IOTA Redundant
Extensive internal diagnostics for data integrity
NO Open wire detection
Optional redundancy
Internal or external field power selection
Supplies Non-incendive field power
Direct / Reverse Input Indication
Galvanic isolation
Analog Output IOTA Redundant
Extensive self-diagnostics
Optional redundancy
Supplies non-incendive field power
Open-wire Bad PV Detection
Non-incendive Power
Digital module
Channels: 16 digital channels
Input Type: 24 VDC
Isolation:500 VDC
Update Rate: ≤10 ms
Power Consumption: ≤5 W
Operating Temperature: -40°C to +70°C (-40°F to +158°F).
Humidity: 5–95% non-condensing.
SC S300 SAFETY CONTROLLER SIL3
Input Voltage: 24 VDC (±10%)
Output Voltage: 24 VDC
Current Capacity: Typically up to 5A
Operating Temperature: -40°C to +70°C (-40°F to +158°F).
Humidity: 5–95% non-condensing
SC S300 SAFETY CONTROLLER SIL3
Digital Inputs:24 VDC
Cycle Time: <10 ms
Operating Temperature: -20°C to +60°C (-4°F to +140°F)
Contact Rating: 5A @ 250VAC
Operating Force: 1.8N minimum
Release Force: 0.1N minimum
Pre-travel: 1.5mm maximum
Digital Input Module
Input Channels:32
Galvanic Isolation: 1500 VAC RMS or ±1500 VDC
Isolation Technique:Optical (in IOM)
DI Power Voltage Range:18 to 30 VDC
ON Sense Voltage/Current:13 VDC (min) or 3 mA (min)
OFF Sense Voltage/Current:5 VDC (max) or 1.2 mA (max)
nput Impedance:4.2 K
Absolute Delay Across Input Filter and Isolation:5 ms ± 20%
Redundant Net Interface Module
REDUNDANT NET INTERFACE MODULE
CAGE CARD
24 VDC
(PN-14251 / 14251)
ANALOG OUTPUT MODULE
CCSDRX01
I/O LINK INTERFACE
FIBER OPTIC CONVERTER
9 PORTS
ANALOG OUTPUT MODULE
Quad Processor Pack
Two -synchronous- processors
Flash memory for system and applicationprogram
RAM with battery backup (battery located inBKM-0001)
Data comparators for the processors and theirmemory
Minimum and maximum execution timemonitor
Memory error handler
1oo2D functionality
24V and 5V monitoring
Emergency Shut Down Input (24V)
Two outputs (for non-redundant resp.redundant IO)
ACTUATOR
MODUTROL IV MOTOR
NON-SPRING RETURN
FOOT MOUNTED
4-20 MA MODULATING CONTROL SIGNAL
160 DEGREE STROKE
15-30 SECONDS TIMING
8.5 NM / 75 LB-IN TORQUE RATING
15 VA
120 VAC
50/60 HZ
POWER SUPPLY MODULE
POWER SUPPLY
8.5AMP
200-240VAC
Rated inputvoltage:110 VAC
Input voltagerange:85V~132VAC
Input frequency:50 / 60 Hz (47 ~ 63 Hz)
Max. input power:110 VA / 42 W
Inrush current:20A peak and lower (within8 ㎳ )
Power Supply Module
Program memory capacity: 640KB
I/O points(installable):3,072 points
Max. I/O memory contact:32,768 points
Symbolic variablearea(A):128KB
I variable:4KB
Flag variable F:4KB
Operator:18
Basic functionblock:43
memory backup module
C300v5 controller
memory backup module
C300 Memory Backup Assembly
Power Requirements: 24 V DC
Current Draw: 150 mA
Operating Temperature Range: 0°C to 70°C

Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.