Amikon Limited comprehensive Honeywell automation solutions, specializing in the supply of the following core product lines:
Experion PKS ,TDC 3000, TDC 2000, Distributed Control Systems,Experion LS,Safety Manager™ Safety Instrumented Systems,FSC™ (Fail Safe Controller) Safety Systems Additionally,we specialize in providing critical Obsolete Parts for discontinued Honeywell equipment across all legacy systems.
Whether you require components for specific platforms (such as Experion PKS or TDC 3000), or need to source replacement or obsolete parts based on equipment functionality, please Email now: info@amikon.cn.
We are committed to sourcing the Honeywell process control products you need.
Amikon Limited comprehensive Honeywell automation solutions, specializing in the supply of the following core product lines:
Experion PKS ,TDC 3000, TDC 2000, Distributed Control Systems,Experion LS,Safety Manager™ Safety Instrumented Systems,FSC™ (Fail Safe Controller) Safety Systems Additionally,we specialize in providing critical Obsolete Parts for discontinued Honeywell equipment across all legacy systems.
Whether you require components for specific platforms (such as Experion PKS or TDC 3000), or need to source replacement or obsolete parts based on equipment functionality, please Email now: info@amikon.cn.
We are committed to sourcing the Honeywell process control products you need.
24 V supply current: max. 25 mA
5 V supply voltage: 5 Vdc ± 5%
5 V supply current: max 1.2 A
Output supply voltage: 15—31 Vdc
Output resistance: approx. 1.1 kΩ
Short circuit proof: continuous
Voltage (high): 15—32 Vdc
Voltage (low): <4 V (reverse polarity protected)
Input current: approx. 8mA at 24 Vdc
Output current: 750mA per output
Power Supply Unit 24/5 Vdc, 16A (conformal coated)
Operating temperature:-5°C-+70°C (+23°F-+158°F)
Storage temperature: -40°C-+85°C (-40°F-+185°F)
Relative humidity: 10-95% (non condensing)
Approvals:CE, TUV, UL, CSA, FM
24 V supply voltage: 24 V DC -15%-+30%
24 V supply current:
< 6 A at 24 Vin (16 A load)
< 7 A at 20.4 Vin (16 A load)
Inrush current: < 5 A at 24 Vin
Hold-up time: < 1ms
Outputs per module:32
Galvanic Isolation:2 groups of 16 outputs
Operating Voltage:10.5 to 32 VDC
Output Type:High side driver
Peak Voltage:32 VDC
AC Frequency:N/A
ON Voltage Drop:0.15 VDC @ 0.5 A load
Experience gained from over 100,000 units installed worldwide
Improved reliability
Optional HART® over 4-20mA output
Can detect a wide range of hydrocarbon gases including solvents
Increased reliability with no moving parts
Increased stability from self compensating optics
Immune to long term component drift
Remote functional gas test facility
Response time: T50 < 3 seconds, T90 < 4 seconds (methane)
Operational and certified: -40° to + 65°C temperature range