Amikon Limited comprehensive Honeywell automation solutions, specializing in the supply of the following core product lines:
Experion PKS ,TDC 3000, TDC 2000, Distributed Control Systems,Experion LS,Safety Manager™ Safety Instrumented Systems,FSC™ (Fail Safe Controller) Safety Systems Additionally,we specialize in providing critical Obsolete Parts for discontinued Honeywell equipment across all legacy systems.
Whether you require components for specific platforms (such as Experion PKS or TDC 3000), or need to source replacement or obsolete parts based on equipment functionality, please Email now: info@amikon.cn+86-18020776786.
We are committed to sourcing the Honeywell process control products you need.
Amikon Limited comprehensive Honeywell automation solutions, specializing in the supply of the following core product lines:
Experion PKS ,TDC 3000, TDC 2000, Distributed Control Systems,Experion LS,Safety Manager™ Safety Instrumented Systems,FSC™ (Fail Safe Controller) Safety Systems Additionally,we specialize in providing critical Obsolete Parts for discontinued Honeywell equipment across all legacy systems.
Whether you require components for specific platforms (such as Experion PKS or TDC 3000), or need to source replacement or obsolete parts based on equipment functionality, please Email now: info@amikon.cn+86-18020776786.
We are committed to sourcing the Honeywell process control products you need.
Safe active/passive digital input FTA
115 V AC/DC, 16 channels
Field termination assembly module
16-channel safe input converter module
universalfor both 115 V AC and/or 115 V DC
All inputs are galvanically isolated
Safe current-limited digital input FTA
24 V DC, 16 channels
Sixteen channels
eight channels with a 250 mA
canbe connected to the TSDI-1624C module
via a system interconnection cable (SICC-0001/Lx)
This cable isplugged into
the SIC connector on the FTA module
and connects to a (redundant pair of) SDI-1624module(s)
Safe digital output module
110 V DC, 0.32 A, 4 channels
Ability to de-energizel
Ability to de-energize via secondary meansl
Crosstalk between outputsl
Functioning of the suppression diodes
Safe digital output module
110 V DC, 0.32 A, 4 channels
Ability to de-energizel
Ability to de-energize via secondary meansl
Crosstalk between outputsl
Functioning of the suppression diodes
Safe loop-monitored digital output module
48 V DC, 500mA, 4 channels
Ability to de-energize
Ability to de-energize via secondary means
Cross talk between outputsl
Function of the suppression diodes
Lead breakage in the (external) output wiring
Short circuit of the outputs
Safe loop-monitored digital output module
48 V DC, 500mA, 4 channels
Ability to de-energize
Ability to de-energize via secondary means
Cross talk between outputsl
Function of the suppression diodes
Lead breakage in the (external) output wiring
Short circuit of the outputs
Safe digital output module
48 V DC, 0.75 A, 4 channels
Ability to de-energizel
Ability to de-energize via secondary meansl
Crosstalk between outputsl
Functioning of the suppression diodes
Safe digital output module
48 V DC, 0.75 A, 4 channels
Ability to de-energizel
Ability to de-energize via secondary meansl
Crosstalk between outputsl
Functioning of the suppression diodes
Safe loop-monitored digital output module
24 Vdc, 1 A, 4 channels
Ability to de-energize
Ability to de-energize via secondary means
Cross talk between outputs
Function of the suppression diodes
Lead breakage in the (external) output wiring
Short circuit of the outputs
Safe digital output module
24 Vdc, 2 A, 4 channels
Ability to de-energize the output
Ability to de-energize the group
(via secondary means)
Crosstalk between outputs, and
Functioning of the suppression diodes
Safe digital output module
24 Vdc, 2 A, 4 channels
Ability to de-energize the output
Ability to de-energize the group
(via secondary means)
Crosstalk between outputs, and
Functioning of the suppression diodes
Space requirements: 4 TE, 3 HE (= 4 HP, 3U)
Power requirements: 5 V DC, 30 mA
Number of outputchannels:2
Output specification(mA):Active or passive, 0-20 / 4-20 mA
D/A converter: 12-bit
Off current: < 0.05 mA
Maximum loadcapacitance:100 nF
WDG input current: 0.5 mA
DIGITAL INPUT MODULE
LINE MONITORED W/ FAULT MONITOR
16 CHANNELS
Functional tests of the various trip levels applied
Channel independence
Monitoring of supply voltage to input devices
Earth connection
Used supply voltages
DIGITAL INPUT MODULE
LINE MONITORED W/ FAULT MONITOR
16 CHANNELS
Functional tests of the various trip levels applied
Channel independence
Monitoring of supply voltage to input devices
Earth connection
Used supply voltages
ANALOG INPUT MODULE
24VDC
16 CHANNEL
Absolute accuracy
Correct conversion over the full range
Crosstalk between inputs
Channel input filters
Internal supply voltages
ANALOG INPUT MODULE
24VDC
16 CHANNEL
Absolute accuracy
Correct conversion over the full range
Crosstalk between inputs
Channel input filters
Internal supply voltages
two processors running synchronously
flash memory for system and application program
RAM with battery backup
a redundant communication link
RAM for the redundant communication link data
data comparators for the processors and their memory
data exchange with its communication modules
Surge Protection±1kV (I/O lines)