Amikon Limited comprehensive Honeywell automation solutions, specializing in the supply of the following core product lines:
Experion PKS ,TDC 3000, TDC 2000, Distributed Control Systems,Experion LS,Safety Manager™ Safety Instrumented Systems,FSC™ (Fail Safe Controller) Safety Systems Additionally,we specialize in providing critical Obsolete Parts for discontinued Honeywell equipment across all legacy systems.
Whether you require components for specific platforms (such as Experion PKS or TDC 3000), or need to source replacement or obsolete parts based on equipment functionality, please Email now: info@amikon.cn+86-18020776786.
We are committed to sourcing the Honeywell process control products you need.
Amikon Limited comprehensive Honeywell automation solutions, specializing in the supply of the following core product lines:
Experion PKS ,TDC 3000, TDC 2000, Distributed Control Systems,Experion LS,Safety Manager™ Safety Instrumented Systems,FSC™ (Fail Safe Controller) Safety Systems Additionally,we specialize in providing critical Obsolete Parts for discontinued Honeywell equipment across all legacy systems.
Whether you require components for specific platforms (such as Experion PKS or TDC 3000), or need to source replacement or obsolete parts based on equipment functionality, please Email now: info@amikon.cn+86-18020776786.
We are committed to sourcing the Honeywell process control products you need.
Operating Voltage:24 VAC ± 10%
Power Consumption:15 VA
6 DOs (Triac output, 2 reserved for internal actuator)
Maximum voltage: 24 VAC
Maximum continuous current: 500 mA
Minimum current: 30 mA
3 AOs, 0 -10 Vdc
Resolution: 12-bit
Type number: FS-IOBUS-CPIOX
Approvals: UL, CSA
Connector (top): 34 pole latch (male)
Connectors (other): 34 pole latch (female)
The IOBUS-CPIOX6 is used for
connection between controller chassis
and I/O chassis in position 1,2, 3, 4, 5, and 6.
Power supply 24V DC
Rated Current 55mA at 24V
Power dissipation 1.22W at 24V DC with
20mA loop current & 250 Ohm load
Power Indication Green LED
Power/DCS to Field 1500 VAC
Voltage Input 24V DC
Interface to DCS 4 to 20mA with HART
Transfer accuracy at 200C +/- 20uA
Output Channels 16
Output Ripple < 100 mV peak-to-peak at
power line frequency, across 250 load
Output Temperature Drift 0.005% of Full Scale/°C
Output Readback Accuracy ±4% of Full Scale
Output Current Linearity ± 0.05% of Full Scale nominal
Resolution ± 0.05% of Full Scale
Calibrated Accuracy ± 0.35% of Full Scale (25oC) including linearity
Output Current Range 0 mA, 2.9 mA to 21.1 mA
ST 3000 Smart Pressure Transmitter
Series 900 Differential Pressure
Span : 0-10" to 0-400" H2O/0-25 to 0-1000 mbar
STD924 Body Rating: 3000 psi (210 bar)
E : Wetted process heads
316 St. St, Vent/drain valves and plugs
316 St. St., Barrier diaphragms
316 LSS
Fill Fluid : 1 = Silicone
Input Channels 16 or more digital inputs,
Output Channels 16 or more digital outputs
Operating Voltage 24 VDC (nominal)
Power Consumption Typically <20 W
Operating Temperature -10°C to +60°C
Storage Temperature -40°C to +85°C
Mounting Type DIN rail or panel mount
Communication Protocols Modbus TCP, Profibus,
EtherCAT, CANopen, and other industrial protocols
Operating Voltage 24 VDC
Power Consumption Typically <20 W
Communication Protocols Modbus TCP,
Profibus, EtherCAT, CANopen,
and other standard industrial protocols
Operating Temperature -10°C to +60°C
Storage Temperature -40°C to +85°C
Safety Standard Compliance
IEC 61508 SIL3, ISO 13849-1
and other relevant safety standards
Input Channels Configurable digital and analog inputs
Output Channels Digital and relay outputs
tailored for controlling safety-critical systems
Communication Protocols
Modbus TCP, Profibus,
EtherCAT, CANopen, and
other standard industrial protocols
Safety Certification IEC 61508
SIL2/3, ISO 13849
Processor High-performance processor
with fault tolerance
Operating Voltage 24 VDC
Power Consumption <20 W
Operating Temperature -20°C to +70°C
Storage Temperature -40°C to +85°C
Humidity 5% to 95% non-condensing
Mounting Options DIN rail or panel-mounted
System interconnection cables
connect Safety Manager SC IO modules
to SCA (via an IOTA)
The female 37 position d-sub
connects to channel 1 thru 16
(CN1 position)
or channel 17 thru 32 (CN2 position) of theIOTA
Safety Standard Compliance
IEC 61508 SIL3, ISO 13849-1
Operating Voltage 24 VDC
Power Consumption <15 W
Operating Temperature -10°C to +60°C
Storage Temperature -40°C to +85°C
Mounting Options DIN rail or panel mount
Safety Standard Compliance
IEC 61508 SIL3, ISO 13849-1
Operating Voltage 24 VDC
Power Consumption <15 W
Operating Temperature -10°C to +60°C
Storage Temperature -40°C to +85°C
Mounting Options DIN rail or panel mount
Length 30 feet
Shielding Shielded Twisted Pair (STP)
Unshielded Twisted Pair (UTP)
Operating Temperature Range -20°C to +75°C
Storage Temperature Range -40°C to +85°C
Bandwidth Up to 1 Gbps (Cat5e) or 10 Gbps (Cat6)
Impedance 100 Ohms ± 15%
Certifications CE, RoHS, TIA/EIA-568 compliant
Communication Protocol Ethernet
with fault-tolerant mechanisms
Redundancy Support
Dual redundant communication paths
Input Voltage 24 VDC or 120/240 VAC
Power Consumption Low power, typically under 10 W
Operating Temperature Range -20°C to +60°C
Storage Temperature Range -40°C to +85°C
Humidity 5% to 95% non-condensing