ICS Triplex T3418F
· Product image is representative; revision or series may vary. Contact us to request a specific version.

T3418F

Regent field powered input module

Shipping Information

  • For inventory products, we support same day shipping upon payment.
  • For urgent needs, we offer same-day shipping on most items for orders placed before 2:00 PM UTC+8 Simply mention your preferred next-day shipping when place the order, and your order will be prioritized to minimize downtime.
  • For indent items, typical turnaround is 1-3 weeks, depending on parts availability and scarcity.
Customs & Documentation
We prepare clear, order-specific documentation for every international shipment, including the commercial invoice, packing list and available product or compliance documents. Before dispatch, our logistics team confirms the consignee details, declared value, shipping terms and destination requirements with you. Tracking information is provided after shipment, helping your team prepare for import clearance with confidence.
Documents checked before dispatch · Shipment details confirmed · Global tracking provided
Payment
Payment is by bank wire only in RMB/CNY, GBP, EUR or USD. Amikon does not accept credit cards or provide credit terms. Cleared payment is required before shipment unless the written quotation expressly states otherwise.
Product Condition
Factory New These are new and current items that are procured directly from the manufacturer.
New In Sealed Package Parts are new. They have not been used and still have their original package seal intact.
New in Original Package These parts are new. The packages were not originally sealed by their original manufacturer.
Quantity
Mobile *
Country/Region *
E-mail *
Company
Content *
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Amikong please read our privacy policy.
  • 20+

    years in automation
  • ISO 9001

    certified quality system
  • 12 months

    amikon warranty
  • 2-hour reply

    from your account manager
  • Success Story

    solutions in action
PRODUCT DESCRIPTION

Externally powered switch inputs with DC line monitoring

ICS Triplex T3418F is a Regent field-powered digital input module for sixteen input devices supplied from external nominal 120 V AC or DC power. It senses switch states and returns input information through the controller I/O interface for program processing.

Automatic input-circuit testing supports module diagnostics. With DC-powered inputs and suitable monitoring devices at the field switches, open and short wiring faults can also be detected. Redundant modules require matching field arrangements and application voting; DC line-monitoring claims do not extend to AC inputs.
ACTUAL APPLICATIONS

Where T3418F Fits in Industrial Production Facilities

Use spans process industries and utility facilities, subject to the installed hardware, connections and approved configuration.
  • 01 · OIL & GAS

    Oil Production Installations and Gas Processing Facilities

    Oil production installations with wellhead equipment and storage vessels.Gas processing facilities with separation equipment and compression packages.
  • 02 · CHEMICAL PROCESSING

    Chemical Manufacturing Sites and Process Material Preparation Facilities

    Chemical manufacturing sites with reaction equipment and ingredient dosing.Process material preparation facilities with blending vessels and pumps.
  • 03 · WATER & WASTEWATER

    Municipal Water Treatment and Wastewater Collection Facilities

    Municipal water treatment works with filters and disinfection equipment.Wastewater collection facilities with lift pumps and screening equipment.

Technical specifications for T3418F

  • Product Model
    T3418F
  • Product Parameters
    Regent field powered input module
  • Manufacturer
    ICS Triplex
  • Input channels
    16 with common field power
  • Field power range
    90 to 150 V AC/DC; nominal 120 V AC/DC
  • Maximum field supply current
    150 mA
  • Maximum input current
    2.0 mA
  • Input switching delays
    Turn-on: 10 ms maximum; turn-off: 100 ms maximum
  • Safetybus load
    0.85 load units
  • Heat dissipation
    10 W
  • Field-to-logic isolation
    2500 V minimum
  • Field line monitoring
    DC-powered inputs only; suitable line-monitor devices required
  • Input test interval
    Typically less than 2 seconds; dependent on program scan and I/O size
  • Slot keys
    Upper connector 17; lower connector 7
  • Operating temperature
    0 to +60 degrees C
  • Storage temperature
    -40 to +85 degrees C
  • Relative humidity
    0-95%, noncondensing
  • Fusing
    No internal fuse; external fusing if required
View all additional

Alternative Names

T3418F Regent field powered input module ICS Triplex T3418F 16-point monitored input module T3418F Regent field-powered input unit
SYSTEM & REPLACEMENT CHECK

Information needed before ordering

Three direct checks to secure your system integration and minimize ordering risks.

Information

System integration Replacement check Manuals & support
REGENT EQUIPMENT

Match T3418F to the documented Regent configuration

This Regent Type F module uses nominal 120 V AC or DC field power, not the lower-voltage ratings of T3411F. DC line monitoring requires suitable field devices and the configured fault variables.
Use the approved Regent I/O position and original field drawing; mechanical keys are upper 17 and lower 7. Verify nominal 120 V AC/DC external field power within 90-150 V AC/DC; do not apply T3411F supply ratings.
Verify the exact WINTERPRET definition, point and fault tags, approved thresholds and voting arrangement.

Features:

  • Sixteen externally powered input points
  • Nominal 120 V AC or DC inputs
  • Automatic input circuit testing
The ICS Triplex T3418F regent field powered input module requires the appropriate mounting, connections and configuration to be verified before system integration and commissioning.
INTERCHANGEABILITY

Verify the complete replacement identity before commissioning

Record the complete T3418F identity and compare its hardware revision with the installed item. Retain T3418F, the 90-150 V AC/DC field range and upper 17/lower 7 keys. The lower-voltage T3411F is not an established substitute.
Use the approved Regent I/O position and original field drawing; mechanical keys are upper 17 and lower 7. Verify the exact WINTERPRET definition, point and fault tags, approved thresholds and voting arrangement.
Use the controlled manufacturer procedure and the approved maintenance plan. For energize-to-trip safety inputs, follow the complete line-monitor and fault-alarm requirements. The stated open/short monitoring scope is DC-powered inputs only.

Features:

  • Complete order identity retained
  • Companion equipment and configuration checked
  • No unconditional substitution claim
The ICS Triplex T3418F regent field powered input module requires replacement verification against the complete installed configuration and current manufacturer documentation.
DOCUMENTATION STATUS

Browse the Manuals, Datasheets, Official Documents, Links

Important Notice: Amikon-authored summaries and manufacturer-hosted manuals are listed here. Check the complete product identity and document scope before use. Accessories and additional documents are included only when expressly listed in the quotation.

Features:

  • Verify document identity before procurement or installation
  • Match the complete order to the manufacturer document scope
  • Accessories are supplied only when listed in the quotation
Documentation for the ICS Triplex T3418F regent field powered input module must be checked for document applicability before installation or commissioning.

Important notice

Manuals, software, firmware, cables, calibration data and accessories are included only when listed in the quotation. AMIKON is an independent supplier and is not affiliated with or authorised by the manufacturer.
This content has been produced using multiple sources. Takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
BUYER INFORMATION

Commercial terms without hidden steps

Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • 01

    Shipping & delivery

    Dispatch
    Eligible stock: same / next day
    Carriers
    DHL, FedEx or UPS
    Ship from
    Xiamen, China
    Packed size
    Packed dimensions unconfirmed
    Shipping weight
    Gross weight unconfirmed
  • 02

    Payment & customs

    Payment
    Bank transfer (T/T)
    Currencies
    USD · EUR · GBP · RMB
    Credit cards
    Not accepted
    HS reference
    8538900000
    Origin
    Mexico
  • 03

    Warranty & returns

    Warranty
    12 months from AMIKON
    Inspection
    Label, condition and packing checks
    Returns
    Prior RMA authorisation required
    Compatibility
    Confirm before order
    OEM warranty
    Does not apply
Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • Part checked

    Full suffix recorded
  • Condition checked

    Label and appearance
  • Packing checked

    Antistatic protection
  • Tracking supplied

    Established couriers
  • Sandy Lin

    Dedicated account manager · 15+ years
FREQUENTLY ASKED QUESTIONS

Questions buyers ask about T3418F

Direct answers about identity, compatibility, stock, warranty, payment and shipping.
  • Does T3418F use the same supply as T3411F?

    No. T3418F is nominally 120 V AC/DC with a 90-150 V AC/DC field range. T3411F belongs to the lower-voltage DC option in the shared manual.
  • How many inputs are provided?

    Sixteen externally powered input points share common field power. Match the actual sensor and redundant-module arrangement to the complete manufacturer drawing.
  • Can open and short wiring faults be monitored on AC inputs?

    The manual explicitly restricts this line-monitoring function to DC-powered inputs with suitable devices at the field switches. Do not extend that claim to AC input wiring.
  • Are turn-on and turn-off delays identical?

    No. The T3418F specification gives a maximum 10 ms turn-on delay and maximum 100 ms turn-off delay. The lower-voltage module has different timing values.
  • Which slot keys are specified?

    Upper connector position 17 and lower connector position 7. These are mechanical keys, not electrical terminal or pin numbers.
  • What must be configured for fault reporting?

    Use the exact WINTERPRET module definition, point and Fault Name variables, approved thresholds and voting logic. Safety use also requires the manufacturer alarm and sensor-monitoring provisions.
  • Does the manual establish current certification for a supplied unit?

    No current supplied-unit certification is asserted here. The historical document contains differing certification statements; obtain the applicable manufacturer evidence for the actual equipment.
READY TO VERIFY YOUR PART?

Get a T3418F quote with price, lead time and revision check.

Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: Amikon Limited sells new and surplus products and develops channels for purchasing such products. Amikon Limited is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because Amikon Limited is not an authorized distributor of this product, the Original Manufacturer's warranty does not apply. Amikon Limited is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.
Product

Product Browsing History