Replacement IPD card
SINAMICS S150
Replacement IPD card
for air-cooled Motor Module
basic unit 380-480V
110kW
Replacement IPD card
SINAMICS S120
Replacement IPD card
for air-cooled Motor Module
500-690V, 710kW
Replacement IPD card
SINAMICS S120
Replacement IPD card
for air-cooled Basic Line Module
560kW 500-690V
3AC/680A
Replacement IPD card
SINAMICS S120
Replacement IPD card
for air-cooled Basic Line Module
560kW 500-690V
3AC/680A
G120 Standard Control Unit
SINAMICS G120 CONTROL UNIT
CU240E-2 E-TYPE SAFETY INTEGRATED
STO RS485-INTERFACE
USS-PROTOCOL 6DI, 3DO, 2AI, 2AO
MAX 1F-DI PTC/KTY INTERFACE
USB- AND SD/MMC-INTERFACE
PROTECTION IP20
AMBIENT TEMP 0 TO +50 DEG C
WITHOUT POWER MODULE AND PANEL
Driver Board
HV-IGBT modules: 1900A
Input Voltage Range:+24V DC
Isolation Voltage:min. 4000 V RMS
IGBT Voltage Monitoring:±5%
Gate Drivers Per Phase:2 channels
Current Transformer
CURRENT TRANSFORMER
2000 AMP
15-24VDC
AC Input Range: 0–2000 A AC
Overload Capacity: 130% of Ipn for 10 sec
DC Voltage or Current:4–20 mA (Two-Wire Loop)
Input Voltage: 15–24 V DC ±10%
Power Consumption: <2 W
BUSBAR CURRENT TRANSFORMER
Primary Current (Ipn): Range 50–600 A
Secondary Current (Isn):1 A or 5 A
Frequency: 50/60 Hz
Insulation Voltage:720 V AC
Operating: -25°C to +60°C
Storage: -40°C to +70°C
PSB11-BOARD
PSB11-BOARD/R3 SIC
HP/MC - SINAMICS COMPONENTS (LD)
Link Voltage (DC): Supports 600/510–720 V D
Output Voltage (AC): Up to 480 V AC 3-phase
Continuous Motor Current: Up to 1,600 A
Peak Current: Short-term 2,500 A
Switching Freq: Up to 5–20 kHz
DOUBLE MOTOR MODULE
SINAMICS S120 DOUBLE MOTOR MODULE
INPUT: DC 600V
OUTPUT: 3AC 400V, 3A/3A
FRAME SIZE: BOOKSIZE D-TYPE
INTERNAL AIR COOLING OPTIMIZED PULSE SAMPLE
AND SUPPORT OF THE EXTENDED SAFETY
INTEGRATED FUNCTIONS
INCL. DRIVE-CLIQ CABLE
CPU BOARD
CPU BOARD ELECTRONIC MODULE
FOR CONVERTER
RAM ≤ 256 MB
Flash ≤ 512 MB
Digital I/O:24 VDC, ±10%
Analog Inputs: 0–10 V/4–20 mA
Input Voltage: 24 VDC ±10%
Isolation: Reinforced (3000 VAC)
Max Power Draw: 20–50 W
REPLACEMENT IPD CARD
SINAMICS S120
Replacement IPD card
for air-cooled Basic Line Module
710kW 380-480V 3AC/1500A
Interface Module
SIMATIC ET 200SP
PROFIBUS bundle IM
IM 155-6DP HF, max
32 I/O modules and 16 ET 200AL modules
Multi-hotswap
bundle consists of: Interface module (6ES7155-6BU01-0CN0)
Server module (6ES7193-6PA00-0AA0)
PROFIBUS connector (6ES7972-0BB70-0XA0)
SINAMICS S120 CONTROL UNIT
SINAMICS S120
CONTROL UNIT CU310-2 PN
WITH PROFINET INTERFACE
WITHOUT COMPACTFLASH CARD
Adapter Cable
SINAMICS S120
C/D Type Adapter Cable
FOR MOTOR CONNECTION
2,5MM2 FOR MOTOR MODULES 3-18A
GH180 Power cell
SINAMICS PERFECT HARMONY
GH180 Power cell 200 A GenIV
Power supply unit SL10 230 V
AC/48V DC Pulse
Smart Line Module
SINAMICS S120
Smart Line Module
380-480V 3AC, 50/60 Hz
Output: 510-650 V DC, 1300 A
Rated power: 630kW Built-in unit
IP00 Internal air cooling
incl. Drive-CLiQ cable
CompactFlash card
SINAMICS S120
CompactFlash card
incl. performance expansion
V5.2 Service Pack 3
Replacement power block
SINAMICS Replacement power block
for 380-480V 3AC, 50/60 Hz
1700A Smart Line Module
rectifier Painted modules
and nickel-plated busbars
Replacement power block
SINAMICS Replacement power block
for 380-480V 3AC, 50/60 Hz
1300 A Smart Line Module
rectifier Painted modules
and nickel-plated busbars
Power Stack Adapter
SINAMICS S120 Drive System
Voltage Support:510–720 V DC
Maximum Resolution: 16-bit digital I/O handling
Operating Temperature: 0°C to +55°C
Compatible SINAMICS S120 Modules
Smart Line Module
SINAMICS S120
Smart Line Module
380-480V 3AC, 50/60 Hz
Output: 510-650 V DC,
1700A Rated power: 800kW
Built-in unit IP00 Internal air cooling
incl. Drive-CLiQ cable
SERIES PRESSURE SWITCH
PRESSURE SWITCH
0-50BAR FOR AIR-COOLED
SINAMICS FOR AIR-COOLED
SINAMICS GM150(IGBT)
Adjustable Threshold Range: 0–50 bar
Switch Type: SPDT
Max Voltage: 250 VAC/24 VDC
Current Rating: 6 A resistive load
Operating Temperature: –25°C to +60°C
SINGLE MOTOR MODULE
SINAMICS S120
SINGLE MOTOR MODULE
INPUT: DC 600V
OUTPUT: 3-PH 400V, 3A
FRAME SIZE: BOOKSIZE D-TYPE INTERNAL
AIR COOLING OPTIMIZED PULSE SAMPLE AND
SUPPORT OF THE EXTENDED
SAFETY INTEGRATED FUNCTIONS
INCL. DRIVE-CLIQ CABLE
Thyristor Trigger Board
Input Voltage:24 VDC (±10%)
Isolation: ≥2500 VAC opto-isolation
Synchronization: Matched to 3-phase AC supply
Operating Temperature: 0°C to +55°C
Relative Humidity: Max. 95% (non-condensing)
STANDARD MODULE
Normalizing module
ABO For devices
DC 890-930V, 650A
Nominal: 890–930 V DC
Rated Current: 650 A
Braking Power Dissipation: 400–500 kW
synchronous servo motor
SIMOTICS S
synchronous servo motor
1FT6 27 Nm, 100K, 2000 rpm naturally cooled
IP65 IM B5 (IM V1, IM V3)
incremental encoder sin/cos
1 VSS 2048 S/R (encoder I-2048)
for power/signal connectors:
Outlet direction axial DE without holding brake
CONTROL UNIT
SINAMICS G120 CONTROL UNIT
CU250S-2 DPINTEGRIERT PROFIBUS
SUPPORT OF VECTORCONTROL
EASY POSITIONING EPOS VIAEXTENDED
FUNCTION LICENSE 4 CONFIGURABLEDI/DO
6 DI (3 F-DI), 5 DI, 3 DO (1 F-DO), 2 AI
2 AOSAFETY INTEGRATED STO, SBC
SS1 FURTHERSAFETY FUNCTIONS VIA EXTENDED
SAFETYLICENSE ENCODER: D-CLIQ + HTL/TTL/SSI
RESOLVER/HTL VIA TERMINAL PROTECTION
IP20USB- AND SD/MMC-INTERFACE
BLM power module
AC Line Supply: 3-phase 380–480 V AC
DC Output: 520–650 V DC
Rated Current:18–30 A
Output Power: 15–110 kW
Efficiency: ≥97%
Storage temperature: -25°C to +70°C
Humidity: ≤85% non-condensing
Power supply module
SPARE PART-POWER SUPPLY
INDUSTRIAL
100-240VAC/150W
REV. K8
CV4
CV5
IPC627B/C
IPC827B/C
HMI IPC677B/C
HMI IPC577C
POWER CONTACTOR
contactor AC-1, 140 A, 690 V
40 °C, 3-pole, 480 V AC, 60 Hz
auxiliary contacts: 2 NO + 2 NC
main circuit: ring cable lug connection,
control and auxiliary circuit: screw terminal
size: S3
COMMUNICATION MODULE
COMMUNICATION MODULE
CBC
FOR CAN-BUS COMMS
SPARE PART
SIMOVERT MASTERDRIVES
Isolation: up to 500 V
Supply Voltage: Pulls 24 V DC
Process Data (PZD): 4–6 PZD
Temperature: 0°C – +55°C
TDB MODULE PC BOARD
TDB MODULE PC BOARD
690VAC
FOR CONVERTER MODULE
3-phase AC Voltage: 690 V AC(±10%)
Frequency Tolerance: ±5%
Isolation Voltage: 2000 V AC
Operating Temperature:-25°C to +55°C
DRIVE BOARD
Logic Power Supply: 24 V DC
Analog Inputs:0–10 V, 4–20 mA
Switching Frequency:2–16 kHz
Temperature: -10°C to +50°C
Humidity: ≤85% (non-condensing)
Power supply module
SIMOVERT Master drives
Power supply module
PSU1 For devices with
Designs E through H 3 AC
380-460, 660-690V, 50/60 Hz
and 510-620V DC
890-930 V DC
Inverter IGD trigger board
Input Voltage: 24 V DC
Voltage Range: +15 V to -10 V
Current Capacity: 5–10 A
Switching Frequency: Up to 20 kHz
Galvanic Isolation Voltage: ≥2500 V AC
Operating Temperature: -20°C to +55°C
Storage Temperature: -40°C to +85°C
Inverter drive board
Control Voltage: 24 V DC
Signal Voltage: 5 V/3.3 V
Switching Frequency:12–16 kHz
Current Ratings:55–160 kW
Overload Capacity: Typically 150%
Temperature: –10°C to +40°C
Humidity: ≤90% (non-condensing)
Inverter drive board IGD trigger board
Trigger Voltage/Current:+15 V/-10 V
Switching Frequency: Up to 20 kHz
Isolation Voltage: ≥2000 V AC
Logic Supply: +24 V DC (±10%)
Gate Driver Supply: ±15 V DC
Operating Temperature: 0–55°C
DRIVE BOARD
Power Supply (Control Section): 24 V DC (±20%)
DC Link Voltage Handling:500–800 V DC
Motor Compatibility: up to 100s of kW
Switching Frequency: 2–16 kHz
Digital Inputs/Outputs:≥6 DI/DO
Analog Inputs:≥2 × ±10 V, 4–20 mA
Operating Temperature: 0–45°C
POWER ENTRY CONTROL MODULE
Voltage Range: 3-phase AC input
Frequency: 50/60 Hz (±5%)
DC Link voltage:510–720 V DC
Continuous Current (DC Link): Up to 60–80 A
Auxiliary Voltage Supply: 24 V DC
Aambient Temperature: 0–40°C
G120L Inverter Motherboard
Supply Voltage: 24 V DC (±20%)
Power Consumption: ≤15 W
Motor Compatibility: up to 55 kW
Standard Communication:PROFIBUS DP
Operating Temperature: -20°C to +60°C.
Relative Humidity: ≤95% (non-condensing)
Inverter Power Board
Voltage Range:380–480 V AC
Frequency: 50/60 Hz ±5%
Rated Current:20–200 A
Continuous Power: 10–150 kW
Operating Temperature: -10°C to +50°C (storage up to +70°C)
Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.