Siemens 6ES7135-6TD00-0CA1
Siemens 6ES7135-6TD00-0CA1
Siemens 6ES7135-6TD00-0CA1
Siemens 6ES7135-6TD00-0CA1
Siemens 6ES7135-6TD00-0CA1
Siemens 6ES7135-6TD00-0CA1
· Product image is representative; revision or series may vary. Contact us to request a specific version.
Ships by Thursday, November 26

6ES7135-6TD00-0CA1

Four-channel HART current output module

Shipping Information

  • For inventory products, we support same day shipping upon payment.
  • For urgent needs, we offer same-day shipping on most items for orders placed before 2:00 PM UTC+8 Simply mention your preferred next-day shipping when place the order, and your order will be prioritized to minimize downtime.
  • For indent items, typical turnaround is 1-3 weeks, depending on parts availability and scarcity.
Customs & Documentation
We prepare clear, order-specific documentation for every international shipment, including the commercial invoice, packing list and available product or compliance documents. Before dispatch, our logistics team confirms the consignee details, declared value, shipping terms and destination requirements with you. Tracking information is provided after shipment, helping your team prepare for import clearance with confidence.
Documents checked before dispatch · Shipment details confirmed · Global tracking provided
Payment
Payment is by bank wire only in RMB/CNY, GBP, EUR or USD. Amikon does not accept credit cards or provide credit terms. Cleared payment is required before shipment unless the written quotation expressly states otherwise.
Product Condition
Factory New These are new and current items that are procured directly from the manufacturer.
New In Sealed Package Parts are new. They have not been used and still have their original package seal intact.
New in Original Package These parts are new. The packages were not originally sealed by their original manufacturer.
Quantity
Mobile *
Country/Region *
E-mail *
Company
Content *
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Amikong please read our privacy policy.
  • 20+

    years in automation
  • ISO 9001

    certified quality system
  • 12 months

    amikon warranty
  • 2-hour reply

    from your account manager
  • Success Story

    solutions in action
PRODUCT DESCRIPTION

Four current loops with HART field-device communication

Siemens 6ES7135-6TD00-0CA1 is the SIMATIC ET 200SP AQ 4xI HART HF analog output module. Its four channels provide 0-20 mA or 4-20 mA signals with 16-bit resolution including sign. HART communication is available with the configured 4-20 mA HART range.

The module operates on an A0 or A1 BaseUnit with a 24 V DC supply and provides four separate current outputs for actuator loops. Availability and mapping of HART variables and quality information depend on the selected ET 200SP station configuration.
ACTUAL APPLICATIONS

Industrial Production and Service Sectors

These industry examples describe Siemens' broader market coverage, not verified installations of this exact product. Product suitability depends on the documented configuration and engineering requirements.
  • 01 · FOOD & BEVERAGE

    Bakery, Confectionery and Sugar Manufacturing

    Bakery and confectionery manufacturing across diverse consumer food categories.Sugar manufacturing and processing within the commercial food industry.
  • 02 · WATER & WASTEWATER

    Desalination and Wastewater Treatment

    Seawater desalination for additional freshwater supply within water utilities.Wastewater treatment serving households, communities and industrial water users.
  • 03 · TEXTILE MANUFACTURING

    Manufactured Fibers and Textile Finishing

    Manufactured fiber production for the wider textile manufacturing sector.Textile finishing for materials within the commercial fabric industry.

Technical specifications for 6ES7135-6TD00-0CA1

  • Product Model
    6ES7135-6TD00-0CA1
  • Product Parameters
    Four-channel HART current output module
  • Manufacturer
    Siemens
  • Analog outputs
    4 current-output channels
  • Current output ranges
    0-20 mA; 4-20 mA; 4-20 mA with HART
  • Resolution
    16 bits including sign
  • Supply voltage
    24 V DC; permissible 19.2-28.8 V DC
  • Compatible BaseUnits
    A0 or A1; color code CC00
  • Maximum supply current
    125 mA; rated 115 mA
  • Typical power loss
    1.7 W
  • Output address allocation
    8 bytes for four analog output values
  • Optional input allocation
    20 bytes for four HART variables; an additional 1 byte for QI
  • Minimum cycle time
    3 ms for all channels
  • Settling time
    2 ms without HART; up to 50 ms with HART enabled
  • Output load limits
    Maximum 750 ohm resistance and 10 mH inductance
  • Maximum shielded cable length
    800 m, subject to loop load limits
  • Error limits
    Basic ±0.1 % at 25 °C; operational ±0.3 % over full temperature range
  • Channel isolation
    From backplane bus and load supply; not between channels
View all additional
SYSTEM & REPLACEMENT CHECK

Information needed before ordering

Three direct checks to secure your system integration and minimize ordering risks.

Information

System integration Replacement check Manuals & support
ET 200SP HART OUTPUT INTEGRATION

Coordinate separate current loops, HART mapping and update timing

Use a compatible A0 or A1 BaseUnit and verify the potential-group feed before connecting the actuators. Each current loop needs its own QIn+ and QIn- pair; Siemens prohibits paralleling outputs to increase power or sharing the specified loop routing. The Hn terminals serve HART test access for an optional secondary master. Check total loop resistance and inductance against the documented 750 ohm and 10 mH limits.
Separate the controller's eight output bytes from the optional input data. Four mapped HART variables occupy twenty input bytes, while enabled quality information adds another byte ahead of them. Each variable includes a value and quality code. Verify the selected station configuration before restoring addresses: the manual excludes QI on PROFIBUS DP and restricts HART-variable mapping with the older Standard IM V1.1 configuration.
Allow for both analog response and multiplexed HART traffic when planning commissioning checks. The documented settling time can reach 50 ms with HART enabled, rather than the 2 ms figure without HART. HART processing serves channels sequentially, and an SHC fast sequence temporarily reserves the module. Coordinate command clients and inspect value status and quality codes instead of assuming every unchanged value has just been refreshed.

Features:

  • Separate actuator and HART-test terminals
  • Distinct input/output address mapping
  • Mode-dependent timing and HART access
The Siemens 6ES7135-6TD00-0CA1 requires the documented hardware configuration, installation conditions and interface arrangement to be verified before system integration and commissioning.
INTERCHANGEABILITY

Verify the complete replacement identity before commissioning

Record the full order number, firmware, BaseUnit, interface module and engineering configuration before selecting a spare. Another four-channel analog module does not establish HART compatibility or preserve the mapped input layout. The 2019 manual specifies supported engineering versions and station restrictions, so verify those requirements against the actual project rather than assuming every ET 200SP controller or interface supports the same configuration.
Back up channel ranges, HART-variable assignments, diagnostic enables and the configured STOP response before the approved exchange. Restore the selected QI configuration as well, because enabling it shifts the HART input addresses. Check the actual actuator current and its configured substitute under controlled conditions. A substitute value, disabled channel or output error makes QI invalid even when the separate diagnostic messages are not enabled.
After restoring the separate actuator loops, verify supply status, output current and HART communication for each connected field device. Wire-break monitoring becomes effective from 240 microampere, while short-circuit monitoring requires at least 1 mA; tests below those thresholds are inconclusive. Preserve the documented field-device addressing and one-client-per-channel command discipline, and complete the site's qualified-personnel commissioning checks before returning the process to service.

Features:

  • Exact module and station-version check
  • Range, QI and mapping restoration
  • Loaded-loop and HART verification
The Siemens 6ES7135-6TD00-0CA1 requires replacement verification based on its complete order number, installed hardware, signal configuration and project documentation.
DOCUMENTATION STATUS

Browse the Manuals, Datasheets, Official Documents, Links

Important Notice: Official documents are provided through manufacturer links. Accessories, manuals, cables, calibration data, software, certificates, and other items are not included with this equipment unless listed in the stock item description.

Features:

  • Exact-model manufacturer data and relevant original manual pages
  • Original terminal diagrams, configuration details and manufacturer safety context
  • Accessories and supplied documentation follow the written quotation
Documentation for the Siemens 6ES7135-6TD00-0CA1 includes an independent technical summary and selected original manufacturer pages; check the applicable document edition against the delivered product and approved installation documentation.

Important notice

Manuals, software, firmware, cables, calibration data and accessories are included only when listed in the quotation. AMIKON is an independent supplier and is not affiliated with or authorised by the manufacturer.
This content has been produced using multiple sources. Takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
BUYER INFORMATION

Commercial terms without hidden steps

Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • 01

    Shipping & delivery

    Dispatch
    Eligible stock: same / next day
    Carriers
    DHL, FedEx or UPS
    Ship from
    Xiamen, China
    Packed size
    Confirm final packed dimensions
    Shipping weight
    Confirm final packed weight
  • 02

    Payment & customs

    Payment
    Bank transfer (T/T)
    Currencies
    USD · EUR · GBP · RMB
    Credit cards
    Not accepted
    HS reference
    8538900000
    Origin
    Confirm supplied-unit origin
  • 03

    Warranty & returns

    Warranty
    12 months from AMIKON
    Inspection
    Label, condition and packing checks
    Returns
    Prior RMA authorisation required
    Compatibility
    Confirm before order
    OEM warranty
    Does not apply
Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • Part checked

    Full suffix recorded
  • Condition checked

    Label and appearance
  • Packing checked

    Antistatic protection
  • Tracking supplied

    Established couriers
  • Sandy Lin

    Dedicated account manager · 15+ years
FREQUENTLY ASKED QUESTIONS

Questions buyers ask about 6ES7135-6TD00-0CA1

Direct answers about identity, compatibility, stock, warranty, payment and shipping.
  • Is this the HART input module with a similar order number?

    No. 6ES7135-6TD00-0CA1 is an analog output module for actuators. It is not the 6ES7134 input product. Check the entire article number and terminal function rather than relying on the shared 6TD00 suffix.
  • Can it produce bipolar current or voltage outputs?

    No. The exact model provides 0-20 mA and 4-20 mA current ranges, including a 4-20 mA HART mode. Its ratings explicitly exclude -20 mA to +20 mA; no voltage-output range is established.
  • Do four HART variables mean four additional analog outputs?

    No. The four physical current outputs occupy eight output bytes. Up to four selected HART variables are mapped into a separate 20-byte input area. Optional QI adds one input byte and shifts the HART area by one byte.
  • Does the 2 ms settling figure also apply with HART enabled?

    Not as an unconditional limit. Siemens gives 2 ms in the technical data without HART communication, but the parameter explanation states that settling can vary up to 50 ms when HART is active. Assess the selected operating mode.
  • Can two outputs be connected in parallel to increase capacity?

    No. Siemens explicitly prohibits paralleling outputs to increase power. Each actuator must connect separately to its assigned QIn+ and QIn- terminals, without common cable routing. Hn+ and Hn- are the HART test connections, not spare power outputs.
  • Why can HART variables remain unchanged during a command sequence?

    The documented SHC fast sequence reserves HART communication across the module. Other channels are not processed during that sequence, so their HART values and quality codes remain unchanged. Coordinate client access and evaluate status; an unchanged value alone is not proof of a current measurement.
READY TO VERIFY YOUR PART?

Get a 6ES7135-6TD00-0CA1 quote with price, lead time and revision check.

Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: Amikon Limited sells new and surplus products and develops channels for purchasing such products. Amikon Limited is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because Amikon Limited is not an authorized distributor of this product, the Original Manufacturer's warranty does not apply. Amikon Limited is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.
Product

Product Browsing History