Siemens 6ES7288-3AT08-0AA1
· Product image is representative; revision or series may vary. Contact us to request a specific version.
Ships by Thursday, September 17

6ES7288-3AT08-0AA1

Eight Channel Thermocouple Module

Shipping Information

  • For inventory products, we support same day shipping upon payment.
  • For urgent needs, we offer same-day shipping on most items for orders placed before 2:00 PM UTC+8 Simply mention your preferred next-day shipping when place the order, and your order will be prioritized to minimize downtime.
  • For indent items, typical turnaround is 1-3 weeks, depending on parts availability and scarcity.
Customs & Documentation
We prepare clear, order-specific documentation for every international shipment, including the commercial invoice, packing list and available product or compliance documents. Before dispatch, our logistics team confirms the consignee details, declared value, shipping terms and destination requirements with you. Tracking information is provided after shipment, helping your team prepare for import clearance with confidence.
Documents checked before dispatch · Shipment details confirmed · Global tracking provided
Payment
Payment is by bank wire only in RMB/CNY, GBP, EUR or USD. Amikon does not accept credit cards or provide credit terms. Cleared payment is required before shipment unless the written quotation expressly states otherwise.
Product Condition
Factory New These are new and current items that are procured directly from the manufacturer.
New In Sealed Package Parts are new. They have not been used and still have their original package seal intact.
New in Original Package These parts are new. The packages were not originally sealed by their original manufacturer.
Quantity
Mobile *
Country/Region *
E-mail *
Company
Content *
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Amikong please read our privacy policy.
  • 20+

    years in automation
  • ISO 9001

    certified quality system
  • 12 months

    amikon warranty
  • 2-hour reply

    from your account manager
  • Success Story

    solutions in action
PRODUCT DESCRIPTION

6ES7288-3AT08-0AA1 acquires eight thermocouple signals

Siemens 6ES7288-3AT08-0AA1 is the SIMATIC S7-200 SMART G2 EM AT08 analog expansion module. Eight inputs measure thermocouples or low-level voltage signals. Each channel can use a different supported thermocouple type, with temperature values reported in tenths of the selected degree unit.

The March 2026 Siemens system manual specifies 0.525 W power consumption and 105 mA SM-bus current for this module. Its integrating measurement method requires the filter, sensor range and cold-junction arrangement to be configured together. Allow for startup calibration and verify valid channel data before enabling the associated control task.
ACTUAL APPLICATIONS

6ES7288-3AT08-0AA1 supports distinct temperature and voltage tasks

The official EM AT08 measurement modes and thermocouple ranges support the following engineered tasks. Select the actual sensor and verify its range, reference junction and installation; the module alone does not provide a complete control or safety function.
  • 01 · HIGH TEMPERATURE

    Measure a high-temperature process point

    Acquire a supported high-temperature thermocouple signal with its correct software linearization. For example, the official Type C nominal range is 100 to 2315 degrees C. Check the sensor assembly, cold-junction error and required warm-up when specifying the measurement chain.
  • 02 · SUBZERO MONITORING

    Track a below-zero temperature point

    Use an appropriate supported sensor for a subzero measurement task. The Type T nominal range extends from -200 to 400 degrees C. Preserve sensor polarity and interpret under-range and underflow indications separately from valid negative temperature readings.
  • 03 · LOW-LEVEL VOLTAGE

    Acquire a millivolt measurement signal

    Configure voltage mode when the task requires a low-level electrical measurement instead of thermocouple conversion. The nominal range is -80 to +80 mV with full scale represented by decimal 27648. Match signal limits, filtering and program scaling to this mode.

Technical specifications for 6ES7288-3AT08-0AA1

  • Product Model
    6ES7288-3AT08-0AA1
  • Product Parameters
    Eight Channel Thermocouple Module
  • In stock
    1 unit
  • Manufacturer
    Siemens
  • Analog input channels
    8
  • Temperature representation
    0.1 degree C / 0.1 degree F
  • Voltage resolution
    15 bits plus sign
  • Nominal voltage range
    -80 to +80 mV
  • Input impedance
    At least 10 MOhm
  • Maximum withstand voltage
    +/-35 V
  • Noise rejection
    85 dB at the selected filter frequency
  • Common-mode rejection
    Greater than 120 dB
  • Field-to-logic isolation
    707 V DC
  • Channel-to-channel isolation
    120 V AC
  • Repeatability
    +/-0.05% of full scale
  • Cold-junction error
    +/-2.5 degrees C; specified warm-up applies
  • Maximum sensor cable
    100 m; wire resistance 100 Ohm maximum
  • Power consumption
    0.525 W
  • SM-bus current
    105 mA
View all additional

Alternative Names

6ES7288-3AT08-0AA1 Siemens EM AT08 SMART G2 Eight-Channel TC Input
SYSTEM & REPLACEMENT CHECK

Information needed before ordering

Three direct checks to secure your system integration and minimize ordering risks.

Information

System integration Replacement check Manuals & support
G2 THERMOCOUPLE INTEGRATION

Configure the sensor chain, not just the module

Use the G2 EM AT08 in the documented SMART G2 system. The 03/2026 manual lists this exact article; older SMART modules and RTD modules must not be treated as interchangeable from their names alone.
For each channel, record thermocouple or voltage mode, sensor type, selected unit, filter and cold-junction reference. Temperature data is scaled by ten, while voltage data uses a nominal full-scale value of 27648.
Budget 105 mA on the SM bus. Keep the module thermally stable, route low-level signals away from switching power wiring, and account for startup calibration before the program accepts channel data.

Features:

  • Eight separate sensor configurations
  • Documented range and wire-break diagnostics
  • Filter timing coordinated with the process
The Siemens 6ES7288-3AT08-0AA1 requires sensor identity and measurement configuration to be checked before system integration and commissioning.
INTERCHANGEABILITY

Verify the complete replacement identity before commissioning

Verify 6ES7288-3AT08-0AA1 as the SMART G2 EM AT08 thermocouple module. Retain the same model, mounting orientation and station sequence as required by the G2 manual.
Record sensor types, wire polarity, channel assignments, filters and cold-junction settings. Isolate power to the CPU, expansion modules and related equipment before removing wiring or disengaging the bus connection.
After restoration, check valid data after calibration, known sensor temperatures and alarm behavior. Include the specified warm-up when assessing accuracy and confirm unused inputs follow the official shorting instruction.

Features:

  • Preserve each channel sensor type
  • Verify polarity and reference-junction settings
  • Evaluate valid data after calibration
The Siemens 6ES7288-3AT08-0AA1 thermocouple module requires replacement verification of channel settings, terminal connections and measurement error before release.
DOCUMENTATION STATUS

Browse the Manuals, Datasheets, Official Documents, Links

Important Notice: Extracted from the Siemens S7-200 SMART G2 System Manual, 03/2026, A5E55110929-AB supplied for this product. Original applicable pages remain unchanged. The extract does not replace the complete manual or an engineered installation assessment.

Features:

  • Available Siemens document references are confirmed before order
  • Check EM AT08 Tables A-38 through A-43 and its terminal map
  • Accessories are supplied only when listed in the quotation
Documentation for the Siemens 6ES7288-3AT08-0AA1 requires exact sensor and module identification; confirm manual availability in the written quotation.

Important notice

Manuals, software, firmware, cables, calibration data and accessories are included only when listed in the quotation. AMIKON is an independent supplier and is not affiliated with or authorised by the manufacturer.
This content has been produced using multiple sources. Takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
BUYER INFORMATION

Commercial terms without hidden steps

Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • 01

    Shipping & delivery

    Dispatch
    Eligible stock: same / next day
    Carriers
    DHL, FedEx or UPS
    Ship from
    Xiamen, China
    Packed size
    7.50 × 1.50 × 11.80 cm
    Shipping weight
    Approx. 0.08 kg
  • 02

    Payment & customs

    Payment
    Bank transfer (T/T)
    Currencies
    USD · EUR · GBP · RMB
    Credit cards
    Not accepted
    HS reference
    8538900000
    Origin
    China
  • 03

    Warranty & returns

    Warranty
    12 months from AMIKON
    Inspection
    Label, condition and packing checks
    Returns
    Prior RMA authorisation required
    Compatibility
    Confirm before order
    OEM warranty
    Does not apply
Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • Part checked

    Full suffix recorded
  • Condition checked

    Label and appearance
  • Packing checked

    Antistatic protection
  • Tracking supplied

    Established couriers
  • Sandy Lin

    Dedicated account manager · 15+ years
FREQUENTLY ASKED QUESTIONS

Questions buyers ask about 6ES7288-3AT08-0AA1

Direct answers about identity, compatibility, stock, warranty, payment and shipping.
  • Why do all active channels initially read 32767 after power-up?

    The module performs internal analog-to-digital calibration after power is applied and reports 32767 until valid channel data is available. Initialization time depends on configuration. Prevent the program from treating this startup value as a real process temperature.
  • Does a raw value of 253 mean 253 degrees?

    No. In thermocouple mode, temperature is reported in degrees multiplied by ten, so decimal 253 represents 25.3 degrees in the configured unit. Voltage mode uses a different representation with nominal full scale at decimal 27648.
  • Can eight installed sensors use different thermocouple materials?

    Yes. Siemens permits a different supported thermocouple type on each channel. Keep the sensor identification and software selection aligned; do not configure all channels alike merely because they share one module.
  • Why does opening the cabinet door affect an otherwise steady temperature?

    Air movement and rapid ambient changes can disturb cold-junction compensation at the module connector. Siemens calls for a thermally stable location and specifies compensation for slow ambient changes below 0.1 degree C per minute.
  • Is the published thermocouple accuracy the complete temperature error?

    No. The manual requires the internal cold-junction error of +/-2.5 degrees C to be added to the thermocouple-table error. At least 30 minutes of warm-up is required to meet that specification; evaluate the complete measurement uncertainty.
  • Should unused thermocouple input pairs remain open?

    No. The exact EM AT08 wiring page instructs that unused analog inputs should be shorted. Apply the documented terminal map and isolate electrical power before changing wiring.
  • What is the trade-off when selecting the recommended 100 ms integration?

    Siemens recommends 100 ms integration for thermocouple measurement. With 10 Hz rejection, the eight-channel module update time is 2.450 seconds. Shorter integrations update faster but increase temperature-reading repeatability error.
  • Will disabling the wire-break alarm make a disconnected sensor usable?

    No. Siemens warns that an open-wire condition may produce random values when wire-break alarming is disabled. Fault handling must distinguish an invalid sensor signal from an acceptable process reading.
READY TO VERIFY YOUR PART?

Get a 6ES7288-3AT08-0AA1 quote with price, lead time and revision check.

Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: Amikon Limited sells new and surplus products and develops channels for purchasing such products. Amikon Limited is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because Amikon Limited is not an authorized distributor of this product, the Original Manufacturer's warranty does not apply. Amikon Limited is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.