Number of inputs : 4 per MPC4 card
DC range : 0 to +20 V or 0 to −20 V
AC range : ±10 V max.
Common mode voltage range : −50 to +50 VC
MRR : >60 dB at 50 Hz
Crosstalk : −72 dB
Input impedance : 200 kΩ
DC signals : 0 to 25 mA
AC signals : ±8 mA max
Voltage at min. GAP:−1.6 V
Voltage at max. GAP:−17.6 V
Dynamic range:16 V
Output impedance:500 Ω
Short-circuit current:45 mA
Voltage:−20 to −32 V*
Current:−13 mA ±1 mA (−25 mA max.)
Configurable high-pass and low-pass filters
Frequency range: 0.5 Hz to 20 kHz
Optional integrator to produce a velocity output
Optional 2-wire current or 3-wire voltagetransmission
Certified for use in potentially explosiveatmospheres
A range of installation options are available
Configurable high-pass and low-pass filters
Frequency range: 0.5 Hz to 20 kHz
Optional integrator to produce a velocity output
Optional 2-wire current or 3-wire voltagetransmission
Certified for use in potentially explosiveatmospheres
A range of installation options are available
VM600 series
Humidity: 5% to 95% non-condensing
Vibration: 0.15 g²/Hz (5 to 500 Hz)
Shock: 15 g (11 ms half-sine)
Operating Temperature Range: -20°C to +60°C (-4°F to +140°F)
Storage Temperature Range: -40°C to +85°C (-40°F to +185°F)
GSI 24
GALVANIC SEPARATION
Measuring Range: 0.1 to 1000 Hz
Sensitivity 1 mV/g to 100 mV/g
Operating Voltage 24V DC
Operating Temperature -40°C to +85°C
Signal Type: 4-20 mA or 0-10V
Operating Temperature Range: -25°C to +65°C
Storage Temperature Range: -40°C to +85°C
Humidity: 0-95%
Input Voltage: 48V DC
Module Capacity: The rack can accommodate up to 15 slot modules
Rack Dimensions: 19 inch rack width, in compliance with industry standards
From the Vibro-Meter ® product line
Power supply unit for VM600 system rack (6U)
High performance
Wide input voltage range
Over-voltage protection
Continuous short-circuit proof
Minimal derating within the operating temperature range
6U height
Compact design
Fully VME compatible
Conforms to EC standards for EMC