PULSE TRANFORMER
Isolation Voltage: Typically 2–4 kV
Primary/Secondary Voltage: 5–24 V AC/DC input
Operating Temperature: -40°C to +85°C
Certifications: Complies with IEC/EN
Turns Ratio: 1:1 or custom ratios
Impedance:50–100 Ω
Binary output module
24 binary outputs with enclosed relays (NO contacts)
Current carrying capacity of the relays: max. 1 A
Channel-by-channel isolation of the outputs
Module is capable of redundant operation
Monitoring of the module
Counter for switching cycles (channel by channel)
Analog output module
16 analog outputs, output signal 0/4 ... 20 mA,
channel-by-channel configuration
Load: max. 700 Ohm
Monitoring of loads
Channel-by-channel isolation of outputs
Module is capable of redundant operation
Digital communication with field devices according to
HART protocol (Version 5.0 / 5.1)
Monitoring of modules
Binary input module
32 binary inputs divided into two groups each with 16 inputs
Process current circuits in accordance
with EN 50020 with type of protection EEx ib IIC
Combined installation possible with
"Non-Ex-modules" in one module sub-rack
Signal recording with 1 ms time resolution
Monitoring of module
Central galvanic separation of system inputs
Group-set filter time
Module is capable of redundancy
Binary input module
32 binary inputs divided into two groups each with 16 inputs
Process current circuits in accordance
with EN 50020 with type of protection EEx ib IIC
Combined installation possible with
"Non-Ex-modules" in one module sub-rack
Signal recording with 1 ms time resolution
Monitoring of module
Central galvanic separation of system inputs
Group-set filter time
Module is capable of redundancy
Coupling Unit
Data Rate: Up to 12 Mbps
Isolation:1500 V AC
Power Supply: 24 V DC (±10%)
Power Consumption: Typically 5–10 W
Fieldbus Port: 9-pin D-sub or M12 for PROFIBUS
Operating Temperature:
-25°C to +70°C (-13°F to +158°F)
Humidity: 5–95% noncondensing
Control panel
Type: LCD or TFT color touchscreen
Operating Voltage: 24 VDC (±10%) or 110–230 VAC
Power Consumption: 10–20 W
Operating Temperature: -10°C to +55°C
Storage Temperature: -40°C to +70°C
Humidity: 5–95% (non-condensing)
FIRING PULSE TRANSFORMER BOARD
Model: SDCS-PIN-H41
Part Number: 3ADT320600R1501
Pulse Voltage: 5–24 V DC
Isolated Pulse Voltage: Typically 10–30 V
Output Current: 1–2 A
Primary-to-Secondary Isolation: ≥2500 V AC
Insulation Resistance: >100 MΩ
Fast I/O module
Input Voltage: 24 VDC
Output Current: ≤0.5 A per channel
Channel-to-Channel: 500 VAC.
Channel-to-Backplane: 1500 VAC
Operating Temperature: -25°C to +60°C (-13°F to +140°F).
Humidity: 5–95% non-condensing
Supply Voltage: 24 VDC (±10%) via backplane.
Power Consumption: ≤5 W
HVD BOARD
Voltage Rating: 3.3 kV, 6.6 kV
Control Voltage: 24 VDC
Power Consumption: <20 W
Operating Temperature: 0°C to +55°C
Humidity: Up to 95% RH (non-condensing)
Power Supply Board
Model: SDCS-POW-H01
Part Number: 3ADT318700R1501
Application: Dedicated power supply unit
Input Voltage Nominal: 24 V DC
Range: 20–30 V DC
AC Input Option: support 100–240 V AC (50/60 Hz)
Primary Output: 24 V DC
Continuous: 5–10 A
Peak Current: Up to 15 A
Excitation plate
Model: SDCS-FEX-4a
Part Number: 3ADT314500R1501
Input Voltage Nominal: 24 V DC
Range: 20–30 V DC
Voltage Range: 0–250 V DC
Current Capacity: Up to 20–50 A
Continuous Output Power: ~5–10 kW
Reference Input: 0–10 V DC or 4–20 mA
DCSLink communication options board
Supply Voltage Nominal: 24 V DC
Supply Voltage Range: 20–30 V DC
Power Consumption:Typically <5 W
Operating Temperature: -25°C to +70°C (-13°F to +158°F).
Storage Temperature: -40°C to +85°C (-40°F to +185°F).
Humidity: 5–95% RH (non-condensing).
FIRING PULSE TRANSFORMER BOARD
Model: SDCS-PIN-H41
Part Number: 3ADT320600R1501
Pulse Voltage: 5–24 V DC
Isolated Pulse Voltage: Typically 10–30 V
Output Current: 1–2 A
Primary-to-Secondary Isolation: ≥2500 V AC
Insulation Resistance: >100 MΩ
Power supply board
Model: SDCS-PIN-H51
Order Code/Part Number: 3ADT320700R1501
Nominal Input Voltage: 24 V DC
Input Voltage Range: 20–30 V DC
Primary Output: 24 V DC
Output Current: Typically 2–5 A
Continuous Power: ~60–120 W
Typically ≥85%
I/O MODULE OPTICAL
Type:Optically isolated I/O module
Channels:8–32 digital I/O channels
Data Rate:10/100 Mbps
Isolation Voltage:≥2500 V
Operating Temperature:-40°C to +70°C
Power Supply:24 V DC ±10%
CENTRAL PROCESSING MODULE
Operating Temp: -20°C to +60°C
Power Supply: 24 VDC ±10%
Memory: 512 MB–2 GB RAM
Control board
Power Supply:24 V DC
Power consumption: < 3 W
Supports up to 64 modules
Operating Temperature:–25°C to +60°C
Humidity:≤ 95% (non-condensing)
1KHL015502R0004 N4BDTEBIT
Power Supply:24 V DC
Power consumption: < 3 W
Supports up to 64 modules
Operating Temperature:–25°C to +60°C
Humidity:≤ 95% (non-condensing)
Coupler Module
Power Supply:24 V DC
Power consumption: < 3 W
Supports up to 64 modules
Operating Temperature:–25°C to +60°C
Humidity:≤ 95% (non-condensing)
CONTROL CARD
Power Supply:24 V DC
Power consumption: < 3 W
Supports up to 64 modules
Operating Temperature:–25°C to +60°C
Humidity:≤ 95% (non-condensing)
Coupler Module
Power Supply:24 V DC
Power consumption: < 3 W
Supports up to 64 modules
Operating Temperature:–25°C to +60°C
Humidity:≤ 95% (non-condensing)
Power Supply Module
Output Voltage:24 V DC
Output Current:5 A continuous
Reinforced isolation :3000 V AC input-to-output
Input-to-ground:1500 V AC
Power Factor:≥ 0.95
Operating Temperature:
–25°C to +70°C
Storage Temperature:
–40°C to +85°C
Power Supply Module
Output Voltage:24 V DC
Output Current:5 A continuous
Reinforced isolation :3000 V AC input-to-output
Input-to-ground:1500 V AC
Power Factor:≥ 0.95
Operating Temperature:
–25°C to +70°C
Storage Temperature:
–40°C to +85°C
COBUX-HW INTERFACE CARD
Type: COBUX-HW Interface Card
Operating Voltage:24V DC
Operating Temperature Range:-20°C to +70°C
Storage Temperature Range:
-40°C to +85°C.
Analog inputs: 0–10 V, ±10 V, 4–20 mA
Analog outputs: 0–10 V, 4–20 mA

Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.