Power Supply Module
DC24V PWR Supply
DC24V input (16 ch)
Relay Output (16 ch)
660mA / 3A
Repetitive, cyclic, interrupt, constant scan
Ladder diagram, Instruction List
Basic : 28, Applied : 687
83 ns/Step (for basic instruction)
Power Supply Module
DC24V PWR Supply
DC24V input (16 ch)
Open Collector Output (16 ch)
330mA / 2A
Repetitive, cyclic, interrupt, constant scan
Ladder diagram, Instruction List
Basic : 28, Applied : 687
83 ns/Step (for basic instruction)
PWR Supply
DC24V PWR Supply
DC24V input (16 ch)
Open Collector Output (16 ch)
260mA / 2A
Repetitive, cyclic, interrupt, constant scan
Ladder diagram, Instruction List
Basic : 28, Applied : 687
83 ns/Step (for basic instruction)
3300 XL 8 mm Proximity Probes
330104 3300 XL 8 mm Probe
M10 x 1 thread,with armor
Minimum unthreaded length: 0 mm
Minimum case length: 30 mm
50 5.0 meters (16.4 feet)
02 Miniature coaxial ClickLocconnector
standard cable
05 CSA, ATEX, IECEx Approvals
PROXPAC XL Proximity Transducer
2 8 3300 XL 8 mm probe with Multiple Approvals
0 4 40 mm
Minimum length: 80 mm
0 3 One M20 fitting, two plugs
0 23/4-14 NPT
3300 XL Standard Extension Cable
3300 XL Standard Extension Cable
080 8.0 meters (26.2 feet)
Output Resistance 50 Ω
Extension Cable Capacitance 69.9 pF/m (21.3 pF/ft)typical
12 FluidLoc cable with connectorprotector
Power Supply
MasterLogic-50
AC110~220V PWR Supply
DC24V input (32 ch)
Relay Output (32 ch)
1040mA / 3A
Repetitive, cyclic, interrupt, constant scan
Ladder diagram, Instruction List
Basic : 28, Applied : 687
83 ns/Step (for basic instruction)
Power Supply
MasterLogic-50
DC24V PWR Supply
DC24V Input (8 ch)
Open Collector Output (8 ch) (Note 4)
250mA / 1.5A
Repetitive, cyclic, interrupt, constant scan
Refresh mode
adder diagram, Instruction List
LOGO Power Supply
LOGO!POWER 24 V / 2.5 A
stabilized power supply
input: 100-240 V AC
output:24 V DC/ 2.5 A
CPU 414-3 Centralprocessing unit
SIMATIC S7-400
CPU 414-3 Centralprocessing unit
with: work memory 2.8 MB, (1.4 MB code, 1.4 MB data)
1stinterface MPI/DP 12 Mbit/s
2nd interface PROFIBUS DP
3rd interfaceplug-in IFM module
CPU551 64-bit processor module
SIMATIC TDC
CPU551 64-bit processor module
with digital inputs
Electronic module
SIMATIC DP
Electronic modules for ET 200
PRO 8 DO 24 V DC,
0.5 A Modulediagnostics;
incl. bus module,
Connection module
Proximity Probe HousingAssemblies
16 3300 XL 8 mm probe
10 1.0 m (39 in)
No standoff adapter = 00
00 Without fittings
02 3/4-14 NPT
AISI 304 stainless steel
Proximity Probe HousingAssemblies
16 3300 XL 8 mm probe
10 1.0 m (39 in)
No standoff adapter = 00
00 Without fittings
02 3/4-14 NPT
AISI 304 stainless steel
Proximity Probe HousingAssemblies
16 3300 XL 8 mm probe
10 1.0 m (39 in)
No standoff adapter = 00
00 Without fittings
02 3/4-14 NPT
Velomitor CT Velocity Transducer
19 Adapter,
3/8-in 24 to 1/4-in 18NPT
00 MIL-C-5015 connection interface
04 CSA/NRTL/C
Velomitor CT Velocity Transducer
REPEATER POWER SUPPLY
MTL4544
REPEATER POWER SUPPLY
4/20MA
20-35VDC
2CHANNEL
2/3WIRE TRANSMITTERS
LED INDICATOR
PROFIBUS DP SLAVE MODULE
SIMATIC DP,5
ELECTRON. MODULES FOR ET 200S
2 DO RELAY 24V DC - 230V AC/5A
15 MM WIDTH FIRSTUP SIGNAL
WITH LED SF (GROUP FAULT)
5 PIECES PER PACKAGING UNIT
PROFINET interface module
SIMATIC ET 200AL
PROFINET interface module
IM 157-1 PN
Degree ofprotection IP67
Electronic modules
SIMATIC DP
Electronic modules
for ET 200 PRO 8 DO 24 V DC
0.5 A Modulediagnostics
incl. bus module
Connection module
IO 6ES7194-4..00-0AA0 orderseparately
WEIGHING ELECTRONIC (1 CHANNEL)
SIWAREX WP321
WEIGHING ELECTRONIC (1 CHANNEL)
FOR STRAIN GAUGE LOADCELLS
FULL BRIDGES (1-4 mV/V)
FOR SIMATIC ET200SP
FITS to BU-TYPE A0
RS485-INTERFACE FOR CONNECTION
OF SIWATOOL OR A REMOTE DISPLAY
Digital output module
SIMATIC DP
ET 200ECO PN
16 DO 24 V DC/1.3 A; 8xM12
duplicateassignment
Degree of protection IP67
Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.