PanelView Plus 6 Operator Terminal
Manufacturer:Rockwell Automation
Product Family:PanelView Plus 6 Operator Terminal
Memory:512 MB Flash/ 512 MB RAM
Compatible Hardware:PanelView Plus 6 700-1500
Status indicators:Red and Green LED
Interfaces:Ethernet port, serial port, two USB ports
CompactFlash card slot
Marine Certified:Yes
Operating Temperature:0-55 Degree Celsius
Power input:24VDC
Power Dissipation:70 Watts
DIGITAL INPUT MODULE
Approvals: CE, TUV, UL, CSA, FM
Number of input channels: 16
Input type: According to DIN (=NAMUR)
Switch level: 1.4-1.9 mA
Hysteresis: 0.2 mA ± 0.05 mA
Field wire resistance: Max. 50 Ω
output voltage 7.9-8.7 V
output current 170 mA (short-circuitproof)3
Maximum load capacitance: 100 nF
Test current: Typically 0.5 mA
Output voltage: Typically 0.5 V DC
Field fault voltage: Max. 250 V AC
Analog Output IOTA Redundant
Power supply 24V DC
Rated Current 55mA at 24V
Power Consumption 1.32W
Power/DCS to Field 1500 VAC
DCS side connections 37 pin
DSUB connector on CC-UGIA01
Voltage Input 24V DC
Current Input 4 to 20mA with HART,
CC-UGAI01 in sink mode.
Open wire current <150uA
Velomitor CT Transducer
0 7 Plate Stud 3/8-in 24 to 3/8-in 24
0 0 MIL-C-5015 connection interface
0 0 No Approvals
Sensitivity:3.94 mV/mm/s (100 mV/in/s)±5%
AmplitudeLinearity:±2% to 63.5 mm/s pk(2.5 in/s pk)
3300 NSv Proximity Probes
3300 NSv Probe
1/4-28 UNF thread,with armor
10 1.0 meter (39 in)
01Miniature coaxial ClickLoc connectorwith
connector protector, standardcable
05 Multiple Approvals
3300 NSv Proximity Probes
3300 NSv Probe
1/4-28 UNF thread,with armor
10 1.0 meter (39 in)
01Miniature coaxial ClickLoc connectorwith
connector protector, standardcable
05 Multiple Approvals
Interconnect Cable
Two-conductor 18 AWGtwisted,
shielded cable withright angle
two-socket plugat one end,
terminal lugs atthe other end.
Used withmonitors and with
21128Velocity Transducer Housing.Min.
length: 2.0 ft (0.6 m)
Max. length: 99 ft (30 m)
Armoured Extension Cable
Capacitance: Low capacitance < 50 pF/m
Temperature Range: -40°C to +150°C (-40°F to +302°F)
Impedance: 50–100 Ω
3300 XL 8 mm Proximity Probes
3300 XL 8 mm Probe, 3/8-24 UNFthread
without armor
05 0.5 meter (1.6 feet)
01Miniature coaxial ClickLocconnector with connectorprotector
standard cable
05 CSA, ATEX, IECEx Approvals
Velomitor CT Velocity Transducer
1 2 Plate Stud 3/8-in 24 to M8x1
0 0 MIL-C-5015 connection interface
0 1 through0 4CSA/NRTL/C (Class I, Division 1)
ATEX/IECEx/CSA (Class I, Zone0/1)
Velomitor Piezo-velocity Sensors
01 1/2 - 20 UNF
Sensitivity:3.94mV/mm/s (100 mV/in/s)±5%
Velocity Range:1270 mm/s (50 in/s) peak.
TransverseSensitivity:Less than 5% of sensitivity.
AmplitudeLinearity:±2% to 152 mm/s (6 in/s)peak.
OperatingTemperatureRange:
-55°C to 121°C(-67°F to 250°F)
ControlLogix Discrete output module
Outputs:16-Points
Module Type:Digital AC Output Module
Voltage:120-140 Volts AC
No. of Outputs Sixteen (16) mechanically fused
Voltage Category:120 / 240 Volts AC
Operating Voltage Range:74-265 Volts AC
Backplane Current at 5 Volts:400 mA
Generic Servo Interface Module
Series:ControlLogix
Module Type:Generic Servo Interface Module
Axes per Module:8
Axes per Controller:32
Backplane Current (5Volts):760 milliamps
Backplane Current (24Volts):2.5 milliamps
Power Dissipation:6.2 Watts
SERCOS Data Rate:4 or 8 Megabits-Second
Current Draw (5.1 Volts):1.2 amps
Thermal Dissipation:21.2 BTU-hour
Isolation Voltage:50 Volts Continuous
SINGLE MOTOR MODULE
SINAMICS S120
SINGLE MOTOR MODULES
INPUT: 600 V DC
OUTPUT: 3-PH 400 V,
210 A FRAME SIZE: CHASSIS
INTERNAL AIR COOLING SUPPORT
OF THE EXTENDED SAFETY
INTEGRATED FUNCTIONS
INCL. DRIVE-CLIQ CABLE
power block
SINAMICS
replacement power block
for 510-750 V DC
380 A Motor Module
3 phases painted modules
and nickel-plated busbars
ACTIVE LINE MODULE
SINAMICS S120
ACTIVE LINE MODULE
INPUT: 3-PH380-480V, 50/60HZ
OUTPUT: 600 V DC, 549 A,
300KW
INTERNAL AIR COOLING INCL
DRIVE-CLIQCABLE
MPC4 machinery protection card
Number of inputs : 4 per MPC4 card
DC range : 0 to +20 V or 0 to −20 V
AC range : ±10 V max.
Common mode voltage range : −50 to +50 VC
MRR : >60 dB at 50 Hz
Crosstalk : −72 dB
Input impedance : 200 kΩ
DC signals : 0 to 25 mA
AC signals : ±8 mA max
4 Channel Relay Output Module
Channel-to-Channel: 1500 VAC
Field-to-System: Reinforced isolation :2500 VAC
Per Channel: 1–2 W
Total: ≤ 8 W
Operating Temperature: -40°C to +70°C (industrial-grade)
Storage Temperature: -50°C to +85°C
Humidity: 0–95% (non-condensing)
SINAMICS Control unit
The Power Module:DC 24 V
External power supply:DC 20 ... 29 V
Max. power consumption:2.00 A
Power loss 12.00 W
Number:2
Output (resistive load):DC 30 V, 0.5 A
Number 15
Switching level: 0→1 11 V
Switching level: 1→0 5 V
PowerFlex 753 AC Drive
Bulletin Number:PowerFlex 753 AC Drive
with Embedded I/O
Corrosive Gas Protection and Cooling Type:
Standard Protection, Forced Air
Voltage Class:400 VAC, 3 PH
Output Current:205 Amps, 110kW ND, 90kW HD
Enclosure Type:Open Type
Input Type:AC Input with Precharge, no DC Terminals
Frame Size:Frame 6
EMC Filtering Options:Filtered
CM jumper installed (preferred)
PowerFlex 753 AC Drive
Bulletin Number:PowerFlex 753 AC Drive
with Embedded I/O
Corrosive Gas Protection and Cooling Type
Standard Protection, Forced Air
Voltage Class:400 VAC, 3 PH
Output Current:205 Amps, 110kW ND, 90kW HD
Enclosure Type:Open Type
Input Type:AC Input with Precharge, no DC Terminals
Frame Size:Frame 6
EMC Filtering Options:Filtered
CM jumper installed (preferred)
PowerFlex 753 AC Drive
Bulletin Number:PowerFlex 753 AC Drive
with Embedded I/O
Corrosive Gas Protection and Cooling Type:
Standard Protection, Forced Air
Voltage Class:400 VAC, 3 PH
Output Current:170 Amps, 90kW ND, 75kW HD
Enclosure Type:Open Type
Input Type:AC Input with Precharge, no DC Terminals
Frame Size:Frame 6
EMC Filtering Options:Filtered
CM jumper installed (preferred)