3300 XL 8 mm Proximity Probes
330103 3300 XL 8 mm Probe
M10 x 1 thread,without armor
Minimum unthreaded length: 0 mm
Minimum case length: 110 mm
10 1.0 meter (3.3 feet)
12 Miniature coaxial ClickLocconnector
FluidLoc cable
00 Not required
3300 XL 8 mm Proximity Probes
330103 3300 XL 8 mm Probe
M10 x 1 thread,without armor
Minimum unthreaded length: 0 mm
Minimum case length: 80 mm
10 1.0 meter (3.3 feet)
12 Miniature coaxial ClickLocconnector
FluidLoc cable
00 Not required
3300 XL 8 mm Proximity Probes
330101 3300 XL 8 mm Probe
3/8-24 UNFthread, without armor
Minimum unthreaded length: 0.0 in
Minimum case length: 1.9 in
10 1.0 meter (3.3 feet)
12 Miniature coaxial ClickLocconnector
FluidLoc cable
00 Not required
3300 XL 8 mm Proximity Probes
330101 3300 XL 8 mm Probe
3/8-24 UNFthread, without armor
Minimum unthreaded length: 0.0 in
Minimum case length: 0.6 in
10 1.0 meter (3.3 feet)
12 Miniature coaxial ClickLocconnector
FluidLoc cable
00 Not required
Velomitor Interconnect Cable
2-conductor twisted
shielded 22 AWG armored cable
with 2- socket moisture-resistant
female connector at one end
terminal lugs at the other end
3300 XL 11 mm Proximity Probes
330704 3300 XL 11 mm Probe
M14 x 1.5 thread,with armor
Minimum unthreaded length:0 mm
Minimum length:100 mm
10 1.0 meter (3.3 feet)
02 Miniature coaxial ClickLocconnector
standard cable
00 Not required
Standard Interconnect Cables
2-conductor twisted
shielded 22AWG (0.5 mm2) cable
with 2-socket moisture-resistant femaleconnector at one end
terminallugs at the other end
(used withmonitors or vibration datacollectors)
Cable operating temperature is-50˚C to 120˚C
Minimum length of 2.0 ft (0.6 m)
maximum length of 99 ft (30 m)
Interconnect Cable
2-conductor 18 AWG twisted
shielded cable with right angle
2- socket plug at one end
terminal lugs at the other end
3300 XL 8 mm Proximity Probes:
330101 3300 XL 8 mm Probe
3/8-24 UNFthread, without armor
Minimum unthreaded length: 0.0 in
Minimum case length: 1.8 in
50 5.0 meters (16.4 feet)
02 Miniature coaxial ClickLocconnector
standard cable
05 CSA, ATEX, IECEx Approvals
3300 XL 8 mm Reverse Mount Probes
330106-05-30-CC-DD-EE M10 x 1 threads
10 1.0 meter (3.3 feet)
12 Miniature ClickLoc coaxialconnector
FluidLoc cable
00 Not required
3300 XL 8 mm Proximity Probes
330104 3300 XL 8 mm Probe
M10 x 1 thread,with armor
Minimum unthreaded length: 0 mm
Minimum case length: 160 mm
10 1.0 meter (3.3 feet)
11Miniature coaxial ClickLocconnector
with connectorprotector, FluidLoc cable
00 Not required
3300 XL 11 mm Extension Cable
080 8.0 meters (26.2 feet)
03 Armored cable with connectorprotector
00 Not required
3300 XL 11 mm Extension Cable
3300 XL 8 mm Probe
330104 3300 XL 8 mm Probe
M10 x 1 thread,with armor
Minimum unthreaded length: 0 mm
Minimum case length: 100 mm
10 1.0 meter (3.3 feet)
11Miniature coaxial ClickLocconnector
with connectorprotector, FluidLoc cable
00 Not required
3300 XL 8 mm Probe
330104 3300 XL 8 mm Probe
M10 x 1 thread,with armor
Minimum unthreaded length: 0 mm
Minimum case length: 100 mm
10 1.0 meter (3.3 feet)
11Miniature coaxial ClickLocconnector
with connectorprotector, FluidLoc cable
00 Not required
3300 XL 8 mm Probe
330104 3300 XL 8 mm Probe
M10 x 1 thread,with armor
Minimum unthreaded length: 0 mm
Minimum case length: 120 mm
10 1.0 meter (3.3 feet)
11Miniature coaxial ClickLocconnector
with connectorprotector, FluidLoc cable
00 Not required
ADAPT Aeroderivative Monitor
Displacement: 0–500 µm peak-to-peak
Velocity: 0–20 mm/s RMS
Acceleration: 0–50 g peak
Frequency Response: 0.5 Hz to 30 kHz
Sampling Rate: Up to 100 kHz
Operating Temperature: -40°C to +85°C
Wind Turbine Monitor
Vibration Velocity: Typical range 0–20 mm/s RMS
Vibration Acceleration: 0–50 g peak
Frequency Range: 0.5 Hz to 10 kHz
Speed Range: 0–3,000 RPM
Analog Outputs: 4–20 mA
Operating Temperature: -40°C to +85°C
Voltage: 18–30 VDC
Power Consumption: <5 W
Wind Turbine Monitor
Vibration Velocity: Typical range 0–20 mm/s RMS
Vibration Acceleration: 0–50 g peak
Frequency Range: 0.5 Hz to 10 kHz
Speed Range: 0–3,000 RPM
Analog Outputs: 4–20 mA
Operating Temperature: -40°C to +85°C
Voltage: 18–30 VDC
Power Consumption: <5 W
Vibration Transmitter
05 0-5 mils pp (0-125 μm pp)
50 5.0 meters (16.4 feet)
01 35 mm DIN rail clips
01 CSA Division 2
Thrust Transmitter
25 25-0-25 mils
50 5.0 meters (16.4 feet)
01 35 mm DIN-rail clips
01 CSA Division 2
Proximitor Probe Extension Cable
Voltage Rating: Rated for ≤ 250V AC/DC
Impedance:50–100 Ω
Temperature Range: -40°C to +120°C
7.5-meter (24.6 ft) cable length
3300 NSv Proximity Probes
330901 3300 NSv Probe
1/4-28 UNF thread,without armor
Minimum unthreaded length: 0.0 in
Minimum case length: 4.0 in
10 1.0 meter (39 in)
02 Miniature coaxial ClickLoc connector
standard cable
05 Multiple Approvals
3300 XL 8 mm Proximity Probes
330102 3300 XL 8 mm Probe
3/8-24 UNFthread, with armor
Minimum unthreaded length: 0.4 in
Minimum case length: 5.6 in
10 1.0 meter (3.3 feet)
02 Miniature coaxial ClickLocconnector
standard cable
00 Not required
3300 XL 8 mm Proximity Probes
330104 3300 XL 8 mm Probe
M10 x 1 thread,with armor
Minimum unthreaded length: 0 mm
Minimum case length: 50 mm
05 0.5 meter (1.6 feet)
01Miniature coaxial ClickLocconnector
with connectorprotector, standard cable
00 Not required
3300 NSv Proximity Probes
330901 3300 NSv Probe
1/4-28 UNF thread,without armor
Minimum unthreaded length: 0.0 in
Minimum case length: 1.0 in
10 1.0 meter (39 in)
02 Miniature coaxial ClickLoc connector
standard cable
00 Not required

Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.