Safe loop-monitored digital output module
                                                    
                                                    
                                                        
                                                        Safe loop-monitored digital output module
48 V DC, 500mA, 4 channels
Ability to de-energize
Ability to de-energize via secondary means
Cross talk between outputsl 
Function of the suppression diodes
Lead breakage in the (external) output wiring
Short circuit of the outputs
                                                    
                                                
Safe loop-monitored digital output module
                                                    
                                                    
                                                        
                                                        Safe loop-monitored digital output module
48 V DC, 500mA, 4 channels
Ability to de-energize
Ability to de-energize via secondary means
Cross talk between outputsl 
Function of the suppression diodes
Lead breakage in the (external) output wiring
Short circuit of the outputs
                                                    
                                                
Safe digital output module
                                                    
                                                    
                                                        
                                                        Safe digital output module
48 V DC, 0.75 A, 4 channels
Ability to de-energizel 
Ability to de-energize via secondary meansl 
Crosstalk between outputsl 
Functioning of the suppression diodes
                                                    
                                                
Safe digital output module
                                                    
                                                    
                                                        
                                                        Safe digital output module
48 V DC, 0.75 A, 4 channels
Ability to de-energizel 
Ability to de-energize via secondary meansl 
Crosstalk between outputsl 
Functioning of the suppression diodes
                                                    
                                                
Safe digital input module
                                                    
                                                    
                                                        
                                                        Safe digital input module
48 Vdc, 16 channels
Ability to receive logic level ‘0’ signals
Ability to receive logic level ‘1’ signals
Crosstalk between inputs
                                                    
                                                
Safe digital input module
                                                    
                                                    
                                                        
                                                        Safe digital input module
48 Vdc, 16 channels
Ability to receive logic level ‘0’ signals
Ability to receive logic level ‘1’ signals
Crosstalk between inputs
                                                    
                                                
Safe loop-monitored digital output module
                                                    
                                                    
                                                        
                                                        Safe loop-monitored digital output module
24 Vdc, 1 A, 4 channels
Ability to de-energize
Ability to de-energize via secondary means
Cross talk between outputs
Function of the suppression diodes
Lead breakage in the (external) output wiring
Short circuit of the outputs
                                                    
                                                
Safe digital output module
                                                    
                                                    
                                                        
                                                        Safe digital output module
24 Vdc, 2 A, 4 channels
Ability to de-energize the output
Ability to de-energize the group 
(via secondary means)
Crosstalk between outputs, and
Functioning of the suppression diodes
                                                    
                                                
Safe digital output module
                                                    
                                                    
                                                        
                                                        Safe digital output module
24 Vdc, 2 A, 4 channels
Ability to de-energize the output
Ability to de-energize the group 
(via secondary means)
Crosstalk between outputs, and
Functioning of the suppression diodes
                                                    
                                                
Analog output module
                                                    
                                                    
                                                        
                                                        Space requirements: 4 TE, 3 HE (= 4 HP, 3U)
Power requirements: 5 V DC, 30 mA
Number of outputchannels:2
Output specification(mA):Active or passive, 0-20 / 4-20 mA
D/A converter: 12-bit
Off current: < 0.05 mA
Maximum loadcapacitance:100 nF
WDG input current: 0.5 mA
                                                    
                                                
Safe analog output module
                                                    
                                                    
                                                        
                                                        0(4)—20 mA, 2 channels
Correct output value 
(current value ± 5%)
Ability to de-energize
Cross talk between analog outputs
                                                    
                                                
igital input module
                                                    
                                                    
                                                        
                                                        DIGITAL INPUT MODULE 
LINE MONITORED W/ FAULT MONITOR
16 CHANNELS
Functional tests of the various trip levels applied
Channel independence
Monitoring of supply voltage to input devices
Earth connection
Used supply voltages
Digital input module
                                                    
                                                    
                                                        
                                                        DIGITAL INPUT MODULE 
LINE MONITORED W/ FAULT MONITOR
16 CHANNELS
Functional tests of the various trip levels applied
Channel independence
Monitoring of supply voltage to input devices
Earth connection
Used supply voltages
                                                    
                                                
ANALOG INPUT MODULE
                                                    
                                                    
                                                        
                                                        ANALOG INPUT MODULE
24VDC
16 CHANNEL
Absolute accuracy
Correct conversion over the full range
Crosstalk between inputs
Channel input filters
Internal supply voltages
                                                    
                                                
ANALOG INPUT MODULE
                                                    
                                                    
                                                        
                                                        ANALOG INPUT MODULE
24VDC
16 CHANNEL
Absolute accuracy
Correct conversion over the full range
Crosstalk between inputs
Channel input filters
Internal supply voltages
                                                    
                                                
Safe analog input module
                                                    
                                                    
                                                        
                                                        Safe digital input module 
Absolute accuracy
Correct conversion over full range
Cross talk between inputs
Output voltage of the 26 Vdc outputs
                                                    
                                                
Safe analog input module
                                                    
                                                    
                                                        
                                                        Safe digital input module 
Absolute accuracy
Correct conversion over full range
Cross talk between inputs
Output voltage of the 26 Vdc outputs
                                                    
                                                
Safe digital input module (24 Vdc, 16 channels)
                                                    
                                                    
                                                        
                                                        DIGITAL INPUT MODULE
24VDC
16 CHANNEL
Safe digital input module 
                                                    
                                                
Power Supply Unit
                                                    
                                                    
                                                        
                                                        Power Supply Unit 
24/5 Vdc, 16A
dual 5 V supply (out of 24 VDC) for
Control Processor and redundant IO
non-redundant IO
                                                    
                                                
Battery and Key switch Module
                                                    
                                                    
                                                        
                                                        backup batteries for CP1 and CP2
Reset key switch
Force Enable key switch
three general purpose inputs (24 VDC)
                                                    
                                                
Quad Processor Pack
                                                    
                                                    
                                                        
                                                        two processors running synchronously
flash memory for system and application program
RAM with battery backup 
a redundant communication link 
RAM for the redundant communication link data
data comparators for the processors and their memory
data exchange with its communication modules
Surge Protection ±1kV (I/O lines)
                                                    
                                                
I/O Extender module
                                                    
                                                    
                                                        
                                                        IO Extender modules, slot 20 and 21
Approvals: CE, TUV, UL, CSA, FM
Space requirements: 4 TE, 3 HE (= 4 HP, 3U)
Power requirements: 5 Vdc, 35 mA
Ripple content: < 50 mV p-p
Holes A5, A7
Large pins A5, A7
                                                    
                                                
Horizontal IO bus backplane
                                                    
                                                    
                                                        
                                                        Horizontal IO bus backplane for redundantIO
Slots:12 
Bus Type:Honeywell HBS
Bandwidth:800 Mbps per slot (shared bus)
Hot-Swap Support:Yes 
Power Distribution:Single 24V DC input 
Input Voltage:24V DC (±15%)
Power Consumption:20W (base), 250W (max load)
Isolation:1000V AC (slot-to-slot)
Surge Protection:±2kV 
                                                    
                                                
Horizontal IO bus backplane
                                                    
                                                    
                                                        
                                                        Horizontal IO bus backplane fornon-redundant IO
Slots:12
Bus Type:Honeywell HBS
Bandwidth:800 Mbps per slot 
Hot-Swap Support:Yes 
Power Distribution:Single 24V DC input
Input Voltage:24V DC (±15%)
Power Consumption:20W (base), 250W (max load)
Isolation:1000V AC (slot-to-slot)
Surge Protection:±2kV
                                                    
                                                
IO Backplane for redundant IO
                                                    
                                                    
                                                        
                                                        Model Number:FS-IOB-0001R
Type:Redundant I/O Backplane
Mounting:19" rack or DIN rail 
Input Voltage:Dual 24V DC
Power Consumption:30W (base), 400W (max load)
Isolation	:1500V AC 
Surge Protection:±4kV 
                                                    
                                                

 
	
		Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.