330101 3300 XL 8 mm Probe
330101 3300 XL 8 mm Probe
3/8-24 UNFthread, without armor
Minimum case length: 3.2 in
05 0.5 meter (1.6 feet)
02 Miniature coaxial ClickLocconnector
standard cable
330101 3300 XL 8 mm Probe
330101 3300 XL 8 mm Probe
3/8-24 UNFthread, without armor
Minimum case length: 5.0 in
10 1.0 meter (3.3 feet)
01Miniature coaxial ClickLocconnector
with connectorprotector, standard cable
3300 XL 8 mm Proximity Probes
330101 3300 XL 8 mm Probe
3/8-24 UNFthread, without armor
Minimum case length: 2.8 in
10 1.0 meter (3.3 feet)
02 Miniature coaxial ClickLocconnector
standard cable
Velomitor Interconnect Cable
Cross-Sectional Area: 0.382 mm²
AWG: 22 AWG
Voltage Rating: Typically 300V AC/DC
Current Rating: Typically ~7A at 25°C
Insulation Resistance: >1000 MΩ·km
Thyristor Unit
Gate Commutated Turn-off (GCT) Thyristor Unit
Allen-Bradley SMC™-3 Soft Starters
Rated Voltage: 110-120V AC
Rated Current: Typically 17 Amps
Power Rating: 110-120V AC
Thyristor Unit
Gate Commutated Turn-off (GCT) Thyristor Unit
Allen-Bradley SMC™-3 Soft Starters
Rated Voltage: 110-120V AC
Rated Current: Typically 17 Amps
Power Rating: 110-120V AC
Thyristor Unit
Gate Commutated Turn-off (GCT) Thyristor Unit
Allen-Bradley SMC™-3 Soft Starters
Rated Voltage: 110-120V AC
Rated Current: Typically 17 Amps
Power Rating: 110-120V AC
3300 NSv Proximity Probes
330903 3300 NSv Probe
M8X1 thread,without armor
Minimum length: 50 mm
10 1.0 meter (39 in)
01Miniature coaxial ClickLoc connector
with connector protector, standardcable
05 Multiple Approvals
Velomitor Piezo-velocity Sensor
00 No adapter
02 ATEX (European)
Sensitivity:3.94mV/mm/s (100 mV/in/s)±5%
Velocity Range:1270 mm/s (50 in/s) peak
Output BiasVoltage:-12 ±3.0 VDC
DynamicOutputImpedance:Less than 2400 Ω
3300 XL 8 mm Proximity Probes
330104 3300 XL 8 mm Probe
M10 x 1 thread,with armor
Minimum unthreaded length: 10 mm
Minimum unthreaded length: 80 mm
15 1.5 meter (4.9 feet)
02 Miniature coaxial ClickLocconnector
standard cable
05 CSA, ATEX, IECEx Approvals
Velomitor Piezo-velocity Sensor
07 3/8 – 16 UNC
04 Multiple approvals (CSA, ATEX)
Sensitivity:3.94mV/mm/s (100 mV/in/s)±5%
Velocity Range:1270 mm/s (50 in/s) peak
Output BiasVoltage:-12 ±3.0 VDC
DynamicOutputImpedance:Less than 2400 Ω
3300 XL 8 mm Proximity Probes
330103 3300 XL 8 mm Probe
M10 x 1 thread,without armor
Minimum unthreaded length: 20 mm
Minimum case length: 40 mm
01Miniature coaxial ClickLocconnector
with connectorprotector, standard cable
00 Not required
3300 XL 8 mm Proximity Probes
330101 3300 XL 8 mm Probe
3/8-24 UNFthread, without armor
Minimum unthreaded length: 3.3 in
Minimum case length: 6.6 in
10 1.0 meter (3.3 feet)
02 Miniature coaxial ClickLocconnector
standard cable
05 CSA, ATEX, IECEx Approvals
Accelerometer
330425 Accelerometer
0 1 ¼-28 UNF integral stud
Sensitivity:2.5 mV/m/s2 (25 mV/g) ±5%.
AmplitudeLinearity:±1% to 735 m/s2 (75 g) peak.
BroadbandNoise Floor:(10 Hz to 15kHz)
0.098 m/s2 (0.01 g) rms.
Standard ArmoredInterconnect Cable
Stainless steel armor overshielded
0.382 mm2 (22 AWG)cable
with a moistureresistant female connector
atthe transducer end
and ringlugs at the monitor end
Standard ArmoredInterconnect Cable
Stainless steel armor overshielded
0.382 mm2 (22 AWG)cable
with a moistureresistant female connector
atthe transducer end
and ringlugs at the monitor end
3300 XL 8 mm Proximity Probes
330101 3300 XL 8 mm Probe
3/8-24 UNFthread, without armor
Minimum unthreaded length: 2.0 in
10 1.0 meter (3.3 feet)
02 Miniature coaxial ClickLocconnector
standard cable
00 Not required
3300 NSv Proximity Probes
330909 3300 NSv Probe
3/8-24 UNF thread,with armor
Minimum case length: 5.0 in
10 1.0 meter (39 in)
01Miniature coaxial ClickLoc connector
with connector protector, standardcable
05 Multiple Approvals
3300 XL 8 mm Proximity Probes
330104 3300 XL 8 mm Probe
M10 x 1 thread,with armor
Minimum unthreaded length: 10 mm
Minimum case length: 60 mm
50 5.0 meters (16.4 feet)
02 Miniature coaxial ClickLocconnector
standard cable
05 CSA, ATEX, IECEx Approvals
3300 XL 11 mm Proximity Probes
330704 3300 XL 11 mm Probe
M14 x 1.5 thread,with armor
Minimum length:80 mm
10 1.0 meter (3.3 feet)
01Miniature coaxial ClickLocconnector
with connectorprotector, standard cable
00 Not required
3300 XL 8 mm Proximity Probes
330104 3300 XL 8 mm Probe
M10 x 1 thread,with armor
Minimum case length: 80 mm
90 9.0 meters (29.5 feet)
02 Miniature coaxial ClickLocconnector
standard cable
05 CSA, ATEX, IECEx Approvals
3300 XL 11 mm Proximitor Sensor
90 9.0 meters (29.5 feet)
systemlength, panel mount
05 Multiple approvals
3300 XL 8 mm Proximity Probes
330101 3300 XL 8 mm Probe
3/8-24 UNFthread, without armor
Maximum case length: 9.6 in
10 1.0 meter (3.3 feet)
01Miniature coaxial ClickLocconnector
with connectorprotector, standard cable
00 Not required
3300 XL 8 mm Proximity Probes
330104 3300 XL 8 mm Probe
M10 x 1 thread,with armor
Minimum case length: 60 mm
05 0.5 meter (1.6 feet)
01Miniature coaxial ClickLocconnector
with connectorprotector, standard cable
05 CSA, ATEX, IECEx Approvals
Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.