Close Menu
Get Parts Quote
Name
Company *
WhatsApp / WeChat (For Faster Quote) *
Email *
Address
City
State / Province / Region
Zipcode
Country
Quantity *
Part Number *
Manufacturer
Preferred Condition
Additional Information
Cancel
In Stock
Ships by Saturday, July 18
Fast Shipping Available

146054-14-10-02-00

3300 Ceramic Capped ProximityProbes

Require for Quote:

Need more help? You may also find the answer in our FAQ section

Shipping Information

  • For inventory products, we support same day shipping upon payment.
  • For urgent needs, we offer same-day shipping on most items for orders placed before 2:00 PM UTC+8 Simply mention your preferred next-day shipping when place the order, and your order will be prioritized to minimize downtime.
  • For indent items, typical turnaround is 1-3 weeks, depending on parts availability and scarcity.

Technical specifications for 146054-14-10-02-00

  • Product Model
    146054-14-10-02-00
  • Product Parameters
    3300 Ceramic Capped ProximityProbes
  • Tariff Code
    8537101190
  • Country of origin
    USA
  • Place of shipment
    Xiamen, China
  • In stock
    1 unit
  • Estimated Shipping Size
    12.2x10.7x3cm
  • Manufacturer
    Bently Nevada
  • Weight
    0.38 kg
  • Overall Case Length Option
    1.4 in
  • Total Length Option
    1.0 meter (3.3 feet)
  • Connector and Cable-Type Option
    Miniature coaxial ClickLocconnector, standard cable
  • Agency Approval Option
    Not required

Description

The Bently Nevada 146054-14-10-02-00 is a 3300 Ceramic Capped Proximity Probe as a state-of-the-art solution for monitoring machinery in aggressive chemical or high-pressure environments. The 146054-14-10-02-00 provides an output voltage that is directly proportional to the distance between the probe tip and the observed conductive surface, and can measure both static (position) and dynamic (vibration) values on fluid-film bearing machines and other rotating equipment.

The 146054-14-10-02-00 features an alumina ceramic cap and a 304 stainless steel probe case, providing robust protection and increased life for applications in anhydrous ammonia or other extreme pH environments. The ceramic capped design of the 146054-14-10-02-00 prevents corrosive gases and liquids from entering the front end of the probe case, ensuring reliable long-term operation in chemically aggressive industrial processes.

The front-end ceramic to metal interface of the 146054-14-10-02-00 is leak tested with helium to ensure a hermetic seal. This rigorous testing of the 146054-14-10-02-00 guarantees that corrosive media cannot penetrate the probe tip assembly, maintaining signal integrity and probe longevity. The 146054-14-10-02-00 is rated to 34 Bar (500 psi) pressure, making it suitable for high-pressure applications where standard proximity probes would be inadequate.

Alternative Names

146054-14-10-02-OO 146054-14-10-OZ-00 146054-14-IO-02-00 146054-I4-10-02-00 146O54-14-10-02-00 146054 14 10 02 00 146054 14 10 02 OO 146054 14 10 OZ 00 146054 14 IO 02 00 146054 I4 10 02 00 146O54 14 10 02 00 146054-14-10-02-05 146054-14-10-02-CN

Information

Overview Manuals Application Notes Product Applications Insertion Guidelines

Features:

  • 3/8-24 UNF Thread Ceramic Capped Probe Without Armor
  • Alumina Cap and 304 Stainless Steel Probe Case for Aggressive Chemical Environments
  • Rated to 34 Bar (500 psi) Pressure
  • Hermetic Front-End Seal with Helium Leak Testing
  • Compatible with 3300 Proximitor Sensor and Extension Cable
The 146054-14-10-02-00 is a forward-mount ceramic capped proximity probe for machinery condition monitoring in aggressive chemical or high-pressure environments. The probe integrates an alumina ceramic tip with an AISI 304 stainless steel case to prevent corrosive gases and liquids from entering the front end of the probe assembly. The front-end ceramic-to-metal interface is helium leak tested to ensure a hermetic seal rated to 34 Bar (500 psi).

The 146054-14-10-02-00 features a 3/8-24 UNF 2A mounting thread and an overall case length of 1.4 inches. The total probe length is 1.0 meter, with a 75 Ω coaxial FEP-insulated cable terminating in a miniature coaxial ClickLoc connector. The ClickLoc connector requires only finger-tight torque and includes a locking mechanism to prevent loosening without special tools.

The 146054-14-10-02-00 Bently Nevada 3300 Ceramic Capped ProximityProbes may still be available for purchase and support from Amikon Limited beyond End-Of-Life (EOL) by the manufacturer (OEM).
Bently Nevada 146054-14-10-02-00 3300 Ceramic Capped ProximityProbes Manuals, Datasheets, Drivers, Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
As a 3300 5 mm system component, the 146054-14-10-02-00 delivers a linear range of 1.52 mm (60 mils) beginning at approximately 0.25 mm from the target surface. The scale factor is 7.87 V/mm (200 mV/mil) with an interchangeability error of ±6.5% when measured in increments of 0.25 mm over the linear range from 0°C to +45°C. The nominal DC resistance from center conductor to outer conductor for the 1.0-meter probe is 7.59 ± 0.50 Ω. 
The 146054-14-10-02-00 does not include a rear fitting or stainless steel tube; the rear of the probe is not sealed. The probe rear must not be exposed to destructive environments such as water, ammonia, ammonium hydroxide, or hydrogen sulfide. For applications requiring protection at both ends, the 146056 series with stainless steel tubing and rear NPT fitting is available.
  • Anhydrous Ammonia Production: Withstands ammonia environments that degrade alternative materials
  • Fertilizer Manufacturing: Used on machinery exposed to highly alkaline or acidic process streams
  • Extreme pH Environments: Ideal for pumps/agitators handling corrosive acids or bases
  • Sour Gas Compressors: Measures vibration/position in compressors handling H₂S and aggressive gases
  • Hydrocarbon Pumps: Monitors high-pressure process pumps exposed to aggressive fluids
This content has been produced using multiple sources.Amikon takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
Thread Specifications: The probe has a 3/8-24 UNF thread.Torque Limits: Do not overtighten the probe. Follow the standard Bently Nevada torque specs (typically max 5.6 N⋅m / 50 in-lbs for 3/8 inch probes).
Gap Voltage: When inserting, ensure you set the initial physical gap between the probe tip and the target (usually AISI 4140 steel) to output a median gap voltage (typically -9.0 VDC to -10.0 VDC), allowing for linear vibration measurement.
Hermetic Seal: The front-end ceramic-to-metal interface is helium-leak tested to prevent corrosive media from entering the probe case.

Technical notes

The 146054, 146055, and 164517 probes were developed forapplications that expose only the front of the probe caseassembly to corrosive gases and liquids. These ceramicprobe assemblies prevent corrosive gases and liquids fromentering the front end of the probe case. We leak test thefront-end ceramic to metal interface with helium to ensure ahermetic seal. These probes do not have a rear fitting orstainless steel tube, so that the rear of the probes are notsealed. You must not expose the rear of these probes todestructive environments such as water, NH3, NH4OH,hydrogen sulfide, etc

FAQs

  • What is the 146054 ?

    +
    The Bently Nevada 146054 series is a robust 3300 XL Ceramic Capped Probe used for precise, non-contact vibration and displacement measurements in harsh industrial environments.
  • What is a ceramic-capped probe used for?

    +
    These probes feature an alumina ceramic tip and are ideal for applications where a standard probe might suffer from wear, chemical exposure, or extreme temperatures, such as in reciprocating compressors.
  • How does the sensing range compare to standard probes?

    +
    The linear range of ceramic-capped probes is slightly shifted compared to standard 3300 XL probes. Extra care is needed when configuring the monitoring system to prevent the probe tip from contacting the shaft
  • What is the exact linear range and scale factor?

    +
    When used with a compatible system, it typically delivers a linear range of 1.52 mm (60 mils) across an operational gap of 0.25 to 1.78 mm. It maintains a standard Incremental Scale Factor (ISF) of 7.87 V/mm (200 mV/mil) ±6.5%.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: Amikon Limited sells new and surplus products and develops channels for purchasing such products. Amikon Limited is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because Amikon Limited is not an authorized distributor of this product, the Original Manufacturer's warranty does not apply. Amikon Limited is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.