Amikon Limited comprehensive Honeywell automation solutions, specializing in the supply of the following core product lines:
Experion PKS ,TDC 3000, TDC 2000, Distributed Control Systems,Experion LS,Safety Manager™ Safety Instrumented Systems,FSC™ (Fail Safe Controller) Safety Systems Additionally,we specialize in providing critical Obsolete Parts for discontinued Honeywell equipment across all legacy systems.
Whether you require components for specific platforms (such as Experion PKS or TDC 3000), or need to source replacement or obsolete parts based on equipment functionality, please Email now: info@amikon.cn+86-18020776786.
We are committed to sourcing the Honeywell process control products you need.
Amikon Limited comprehensive Honeywell automation solutions, specializing in the supply of the following core product lines:
Experion PKS ,TDC 3000, TDC 2000, Distributed Control Systems,Experion LS,Safety Manager™ Safety Instrumented Systems,FSC™ (Fail Safe Controller) Safety Systems Additionally,we specialize in providing critical Obsolete Parts for discontinued Honeywell equipment across all legacy systems.
Whether you require components for specific platforms (such as Experion PKS or TDC 3000), or need to source replacement or obsolete parts based on equipment functionality, please Email now: info@amikon.cn+86-18020776786.
We are committed to sourcing the Honeywell process control products you need.
Communication Protocol:Modbus RTU over RS‑485
Display:128 × 64 pixel LCD
Keypad:5-button navigation
LED Status Bar:Yes (visual feedback)
Power Supply:24 V DC
Operating Temp:–20 °C to +70 °C
Storage Temp:–40 °C to +85 °C
Humidity:0–95 % RH, non-condensing
Galvanic isolation
Open wire detectio
Optional redundancy
Direct / Reverse Input Indication
Supplies Non-incendive field power
Internal or external field power selection
Extensive internal diagnostics for data integrity
Input Voltage:100–240 VAC (universal)
Output Voltage:24 VDC (adjustable up to ~27 V)
Output Current:20 A continuous
Protections:Overcurrent, overvoltage, short-circuit
Operating Temperature Range:–25 °C to +70 °C
Supply voltage: 24 V DC
Reset input voltage: 18 - 70 V DC
Reset input current: 1.1 mA at 24 V DC
Earth fault threshold: 5.5 mA (± 1 mA)
Max. earth current: 25 - 32 mA
Supply voltage: 24 V DC
Reset input voltage: 18 - 70 V DC
Reset input current: 1.1 mA at 24 V DC
Earth fault threshold: 5.5 mA (± 1 mA)
Max. earth current: 25 - 32 mA
Max. output current: 2 A
Isolation 1500 V DC / 1000 V AC
Initial contact resistance: 30 mW
Operating temperature: -5°C-+50°C (23°F-+122°F)
Max. output voltage: 36 V DC / 30 V AC
Power Supply:12–24 V DC
Current Consumption:250 mA @ 24 V DC
Connectivity:Serial (RS‑232);
Mounting:Desk or panel mount with screw terminals
Enclosure Type:Indoor use; IP20 equivalent
Operating Temp:0 °C to +50 °C
Storage Temp:–40 °C to +85 °C
Humidity Limits:Up to 90–95% RH, non-condensing
DIGITAL INPUT MODULE
LINE MONITORED W/ FAULT MONITOR
16 CHANNELS
Functional tests of the various trip levels applied
Channel independence
Monitoring of supply voltage to input devices
Earth connection
Used supply voltages
Channels:Typically 16 I/O
Output Types:Digital(0–10 VDC, 4–20 mA)
Analog Resolution:AI: 16‑bit; AO: 13‑bit
Power Supply:24 V DC nominal
Power Isolation:Galvanic isolation, reverse protection
Operating Temp:–40 °C to +70 °C
Enclosure / Rating:Up to IP66
Channels:Typically 16 I/O
Output Types:Analog (0–10 VDC, 4–20 mA)
Analog Resolution:AI: 16‑bit; AO: 13‑bit
Power Supply:24 V DC nominal
Power Isolation:Galvanic isolation, reverse protection
Operating Temp:–40 °C to +70 °C
Enclosure / Rating:Up to IP66
Medium: Multimode Dielectric Fiber 62.5/125
Wavelength:1300 nm
Maximum:Distance 2 km (1 mile)
Connector:MT-RJ
Voltage:3.3 V
Temperature Industrial:-40 C to +85 C (-40 F to +185 F)
Supply voltage: 24 V DC
Reset input voltage: 18 - 70 V DC
Reset input current: 1.1 mA at 24 V DC
Earth fault threshold: 5.5 mA (± 1 mA)
Max. earth current: 25 - 32 mA
Max. output current: 2 A
Isolation 1500 V DC / 1000 V AC
Initial contact resistance: 30 mW
Operating temperature: -5°C-+50°C (23°F-+122°F)
Max. output voltage: 36 V DC / 30 V AC
Slots Available:5 module slots
Power Input:24 VDC
Operating Temperature:0°C to 60°C (32°F to 140°F)
Storage Temperature:-40°C to 85°C (-40°F to 185°F)
Humidity:5% to 95% RH, non-condensing
Line monitored digital input
Non line monitored digital input
Line monitored ESD input (on Channel 32)
Analog input 0-20mA or 4-20mA
Digital output (0.5 Amp) configurable line monitoring
Multiple digital output (1 Amp or 2 Amp)
with or without line monitoring
Analog output 0-20mA or 4-20mA
Ability to de-energizel
Ability to de-energize via secondary meansl
Cross talk between outputsl
Function of the suppression diodesl
Lead breakage in the (external) output wiringl
Short circuit of the outputs